JHKs photometric standards, N90C10 dichroic

Van der Bliek IR photometric standards: See van der Bliek et al. 1996, A&AS, 119, 547

Name RA(J2000) DEC(J2000) SpT J Err J H Err H K Err K L Err L M Err M
HD590 00 10 12 -18 51 00 F2V 9.200 0.015 8.982 0.026 8.959 0.012 8.892 0.017    
HD1274 00 16 37 -63 51 33 G5V 8.795 0.017 8.432 0.011 8.367 0.005 8.362 0.014    
HD7644 01 15 36 -45 26 00 F6V 9.504 0.007 9.259 0.005 9.216 0.007        
HD8864 01 27 29 +04 27 44 A5 8.632 0.012 8.508 0.009 8.483 0.006        
HD15189 02 26 26 -13 52 46 G0V 8.474 0.021 8.183 0.012 8.145 0.007        
HD16031 02 34 11 -12 22 54 F0V 8.809 0.031 8.521 0.005 8.495 0.015        
HD18847 03 01 25 -19 59 15 F5V 9.033 0.017 8.721 0.008 8.689 0.009        
HD20223 03 13 26 -43 21 57 A9V 8.841 0.006 8.696 0.010 8.668 0.010        
HD29250 04 35 13 -29 38 12 A4IV 9.508 0.022 9.388 0.010 9.381 0.011        
HD60778 07 36 12 -00 08 13 A1V 8.787 0.007 8.714 0.005 8.692 0.019 8.712 0.027    
HD110621 12 43 44 -44 40 30 F8 8.952 0.005 8.613 0.008 8.577 0.007        
SAO245532 18 32 08 -59 27 42 F9 8.884 0.005 8.612 0.006 8.567 0.005        
HD188112 19 54 31 -28 20 22 B9V 10.708 0.006 10.787 0.005 10.860 0.017        
HD202964 21 20 21 -38 24 16 F3V 8.652 0.005 8.323 0.005 8.280 0.012        
HD207288 21 48 18 -17 37 00 G8V 8.838 0.005 8.394 0.005 8.329 0.005        
HD210427 22 10 48 -26 53 00 G1V 9.306 0.021 8.975 0.022 8.917 0.016 8.946 0.021    
HD210863 22 13 26 -08 13 46 G0 8.615 0.013 8.299 0.005 8.260 0.005        
HD211131 22 15 30 -29 07 00 G8V 8.535 0.009 8.061 0.010 8.000 0.025        
HD212874 22 27 19 +04 02 51 A2 9.092 0.005 8.928 0.005 8.908 0.006        
HD214497 22 38 48 -14 48 00 F6V 9.259 0.018 8.973 0.007 8.937 0.005        
HD218814 23 11 42 -56 47 23 A6V 9.367 0.010 9.265 0.005 9.246 0.005        
HD221462 23 32 27 -24 55 55 G3V 8.643 0.016 8.295 0.009 8.250 0.005        

LCO/Palomar NICMOS IR photometric standards.See Persson et al. 1998, AJ, 116, 2475.

Name HST  RA (J2000)  DEC (J2000)  J  Err J  H  Err H  K  Err K  Ks  Err Ks 
9103  S294-D  00:33:15.2  -39:24:10  10.932  0.006  10.657  0.004  10.596  0.005  10.594  0.004 
9104  S754-C  01:03:15.8  -04:20:44  11.045  0.005  10.750  0.005  10.693  0.010  10.695  0.005 
9105  P530-D  02:33:32.1  06:25:38  11.309  0.010  10.975  0.006  10.897  0.006  10.910  0.005 
9111  S361-D  04:49:54.6  -35:11:17  11.246  0.006  11.031  0.006  10.992  0.033  10.980  0.006 
9113  S252-D  05:10:25.6  -44:52:46  11.059  0.005  10.776  0.005  10.708  0.034  10.713  0.005 
9125  S005-D  07:19:38.6  -84:35:06  10.885  0.007  10.598  0.006  10.514  0.013  10.522  0.008 
9129  S209-D  08:01:15.4  -50:19:33  10.914  0.007  10.585  0.006  10.487  0.021  10.496  0.009 
9137  S372-S  09:15:50.5  -36:32:34  11.153  0.007  10.891  0.007  10.830  0.019  10.836  0.010 
9138  S852-C  09:41:35.8  00:33:12  11.354  0.006  11.041  0.006  10.981  0.015  10.982  0.008 
9141  S708-D  09:48:56.4  -10:30:32  11.081  0.008  10.775  0.008  10.715  0.035  10.718  0.010 
9154  S008-D  14:23:45.5  -84:09:58  11.232  0.007  10.990  0.007  10.904  0.009  10.915  0.008 
9157  S273-E  14:56:51.9  -44:49:14  11.341  0.007  10.924  0.005  10.851  0.004  10.849  0.004 
9160  S870-T  15:39:03.5  00:14:54  10.914  0.008  10.701  0.008  10.649  0.010  10.659  0.009 
9170  S875-C  17:27:22.2  -00:19:25  11.132  0.005  10.835  0.005  10.739  0.006  10.744  0.005 
9173  S024-D  18:18:46.2  -80:06:58  11.039  0.007  10.778  0.007  10.693  0.009  10.711  0.008 
9178  S808-C  19:01:55.4  -04:29:12  10.966  0.007  10.658  0.008  10.566  0.014  10.575  0.008