ISAAC is an infrared (1 - 5 μm) imager and spectrograph mounted on the Nasmyth A focus of UT3. It has two independent arms, one equipped with a 1024 x 1024 Hawaii Rockwell array and the other with a1024 x 1024 InSb Aladdin array from Santa Barbara Research Center. The Hawaii arm is used at short wavelengths (1 - 2.5μm). The Aladdin arm is used predominantly at long wavelengths (3 -5 μm) but is also available for short wavelength imaging with broadband filters. Below we summarize in two tables the operational modes and predicted performance of ISAAC. Those tables are intended as a quick feasibility references only: proposers should refer to the detailed information (e.g. User's Manual, Exposure Time Calculator).All instrument modes are offered in both Visitor Mode and in Service Mode).
Imaging Modes
| Instrument Mode | Scale | FOV | limit magnitude | 
|---|---|---|---|
| (''/pixel) | (squared '') | ||
| SW Imaging[1] | 0.148 | 152 x 152 | J=24, H=23, Ks=22 | 
| SW Polarimetry[2] | 0.148 | 3 x 20 x 150[2] | J=23, H=22, Ks=21 | 
| LW Imaging | 0.071 | 73 x 73 | L~16, M_NB ~ 13 | 
| LW Imaging 3.21, 3.28μm | 0.148 | 152 x 152 | L ~16 | 
[2] In polarimetry the FOV consists of three non-overlapping strips each of 20 x 150 arcsec^2.
The limit magnitudes in the table are the J (1.25μm), H(1.65μm), Ks (2.2μm), and L (3.8μm) background limited magnitudes for a point source which would give a S/N of 5 in one hour of typical background conditions and a seeing FWHM of 0.65''. In addition to the standard J, H, Ks, and L broadband filters, ISAAC is equipped with a wide selection of narrow bands (typically =0.015μm) filters. It is not possible to observe with ISAAC with user supplied filters.
Spectroscopic Modes
| Instrument Mode | λ/Δλ | Scale | limit magnitude range | 
|---|---|---|---|
| (''/pixel) | |||
| SW LRes Spectroscopy | 500 | 0.147 | 18-20.5 | 
| SW MRes Spectroscopy | 3000 | 0.147 | 17.5-19.5 | 
| LW LRes Spectroscopy | 500 | 0.147 | 11-14 | 
| LW MRes Spectroscopy | 2000 | 0.147 | 10-13 | 
The limit magnitudes given in the above table are the short wavelength (SW) and long wavelength (LW) magnitudes of a point source spectrum which would give a S/N of 5 per resolution element in the continuum in one hour under typical background conditions, seeing FWHMof 0.65'', and using a 1.0'' slit. Limits on IR spectroscopic capabilities vary strongly with wavelength due to the absorption/emission spectrum of the atmosphere, the range of limit magnitudes given in the table reflects this variation.