Paranal: Important recent changes regarding instrumentation and facilities

This section describes important changes which took place or are expected during the three priods preceding the Period of the call.

UT instruments and facilities

UT1 - Antu

  • KMOS:
    • KMOS is hosting public surveys over 3 years, since P116. This will increase pressure on UT1, due to the reduced amount of open time available.
  • FORS2:
    • As of P117, the Imaging (IMG) observations will no longer be accompanied by a standard field observation. The photometric calibration for the broadband filters b_high, v_HIGH, R_SPECIAL, and I_BESS shall be performed using Gaia stars in the field of view, which can be checked by the users using the functionality now available in the ObsPrep. In case that there are no Gaia stars available (~ 10% of pointings), then a standard field observation will be performed by the observatory. For any other filters where photometry is not possible using GAIA, the users are expected to provide their own STD field observations attached to the science OB in the form of a concatenation. For this purpose, STD field OBs used by observatory in the past, are now available to all users, in P2. Additionally, because of a change in the FORS2 calibration plan, users should also be aware that absolute photometry down to the 3% level is no longer feasible. Furthermore, only extinction values will be possible to compute, using the standard fields or the Gaia stars.

UT2 - Kueyen

  • FLAMES:
    • UVES fibre 3 on plate 2 has been taken out of service as it got damaged.

UT3 - Melipal

UT4 - Yepun

  • MUSE:
    • Astronomers are encouraged to use the MUSE Wide Field Mode with Adaptive Optics, because it is more efficient and suitable than non-AO for most science cases. Until now, a large fraction of MUSE observations were taken in Wide Field Mode without Adaptive Optics (NOAO). While the NOAO mode is essential for programmes gathering information over the 582 - 597 nm wavelength which is otherwise blocked by the Na Notch filter, the benefits of AO are many-fold. Not only the operations at the telescope are routine, but importantly seeing is improved in any observing conditions (poor seeing, light cirrus, high wind speed) while proven to be more stable during long exposure times. In case no Natural Guide Star is available, the so-called Tip-Tilt free mode uses the telescope field stabilisation still providing a significant improvement on image quality. As a result, shorter exposure times are required in AO mode to reach equivalent image quality.
  • HAWK-I:
    • The HAWK-I calibration plan does no longer include the observation of 2MASS touchstone fields for photometric calibration. If a photometric accuracy < 0.05-0.1 mag is required, users must request special calibrations in their proposals and include this time to the total time request.

Incoherent combined focus

  • ESPRESSO:
    • The LFC has been put back in operations and offered for scientific use on Nov. 2025. In addition, OBs requesting its use have been added to the ESPRESSO observing queue. Details about the recent activities and performance of the LFC can be found in the latest version of the user manual.

Visitor focus

  • The UT1 Nasmyth A focus is not available for Visitor Instruments, due to the installation of the field corrector lens for MOONS.
  • Potential users of a visitor focus are requested to consult the VLT Visitor Instruments page.

VLTI instruments and facilities

General:

  • For new users to VLTI needing assistance to prepare their VLTI proposals, the community supported VLTI Expertise Centres - disseminated throughout Europe - can offer in-depth support. They also offer support for advanced data reduction and interpretation.
  • Monitoring Programme proposals on the VLTI-ATs and VLTI-UTs are accepted for both GRAVITY and for MATISSE.

VLTI-UTs:

  • In P118. after analysis of the LGS-VIS commissioning data, the limiting magnitude of 17 mag is only offered in the 30%,  or lower, tubulence categories. It is fixed at 15.5 mag otherwise.

VLTI-ATs:

  • ESO will continue a scheme to optimise operations for aperture synthesis with the VLTI. This scheme only applies to service mode proposals using ATs with PIONIER, GRAVITY and MATISSE. The reader is referred to the Period 117 VLTI manual for further details.

Instruments

  • One VLTI visitor focus (VISITOR 1) is available. Potential users are requested to consult the VLTI Visitor Instrument page.
  • GRAVITY is offered on all AT configurations as well as on all four UTs with the GPAO adaptive optics system (NGS_VIS and the off-axis NGS_IR) in Service and Visitor modes.
    • ESO invites proposals with the goal of performing astrometric measurements (see, e.g., the following articles: Gravity collaboration, 2017 A&A 602, A94 and The Messenger 170, 10). Proposers who need help with the preparation of GRAVITY astrometric observations are invited to contact the ESO Helpdesk well in advance of the deadline.
    • For the GRAVITY dual-field wide mode at the limit of system performance, in particular for crowded fields or embedded objects, it is recommended to confirm positions and magnitudes of AO-guide and fringe tracking stars in images with sufficient angular resolution, not relying purely on catalogs. Such images might also be provided as additional finding charts. We are in the process of further characterizing the performance of the GRAVITY-wide mode as a function of separation of the FT star and the atmospheric conditions. Note that the offered maximum separation of 30 arcsec distance may be optimistic unless the weather is excellent and both the FT and SC stars are bright. With more typical conditions, the maximum separation may be somewhat smaller. A performance estimation tool for this mode is currently under development by the JMMC.
    • in P118 the GRAVITY Dark Hole Mode is offered. Dark Hole provides access to increased contrast between the fringe tracking and science objects for dual-field on-axis observations by reducing (nulling) excess flux from the bright fringe tracking object at the science object position. The mode is offered for small separations of 60-200 mas. It was developed for exoplanet observations, but may also benefit other science cases.
    • An optics upgrade is planned for the first quarter of 2028, and the VLTI operations will be halted for several weeks.
  • MATISSE is offered on the UTs (supported by the visible GPAO AO system) and on all the ATs configurations in Service and Visitor modes.
    • MATISSE with the UTs is offered with UT/GPAO for natural guide stars in visible light in both standalone and GRA4MAT modes.
    • MATISSE is fully available in the GRA4MAT mode with the ATs and UTs, including chopping. The HIGH+ mode is only available with GRA4MAT. The GRA4MAT limiting magnitude at the UTs has been improved to K<11mag for the fringe tracking object.
  • PIONIER PIONIER is offered on all ATs configuration in both service and visitor mode. See the overview or overheads pages.
    • The cooling pump of the detector is currently not performing, and the temperature sensor of the detector is not functional. This situation may affects the performance of the instrument. While a spare for the pump has been identified, the temperature sensor problem remains. A direct consequence of the instrument status is that no Large nor Monitoring Programs are offered for Period 114.
  •  ASGARD (Visiting Instrument):  All the remaining ASGARD modules (NOTT and BIFROST-HR) should be integrated and partially commissioned by the beginning of P118, including operation on UTs.  A fraction of the ASGARD observing time is open to the community, pending successful review of the observing proposals by the OPC/DPR. A preliminary coordination with the ASGARD consortium is mandatory. Interested users can contact the consortium through the  ASGARD website