Slit positions in the ISAAC focal plane
The true positions of the slits on the detector are recorded in the following tables. Users can use theses table to determine exactly where the slitwas during acquisition. The tilt is given in terms of the position angle of the slit on the sky when the rotator angle is zero.
Observations from Feb 02 2010 - present
Observations from Aug 20 2009 - Feb 2010
Observations from May 06 2008 - Aug 2009
Observations from May 14 2005 - May 2008
Observations from Jan 27 2004 - April 1 2005
Observations from March 27 2003 - Jan 27 2004
| Slit | Filter | Objective (Arm) | X center | Ycenter | Width | Length | Tilt |
| 0.3 |
SZ |
S2 (SW) |
513.5 |
512.5 |
2 |
813 |
0.55 |
| 0.3 |
H |
S2 (SW) |
513.7 |
512.5 |
2 |
813 |
0.55 |
| 0.3 |
NB_1.06 |
S2 (SW) |
513.8 |
513.0 |
2 |
813 |
0.55 |
| 0.3 |
NB_1.08 | S2 (SW) |
514.1 |
513.0 |
2 |
813 |
0.55 |
| 0.3 |
NB_1.64 |
S2 (SW) |
513.8 |
513.0 |
2 |
813 |
0.55 |
| 0.3 |
NB_2.29 |
S2 (SW) |
513.7 |
512.5 |
2 |
813 |
0.55 |
| 0.3 |
NB_2.09 & NB_2.13 |
S2 (SW) |
514.0 |
512.0 |
2 |
813 |
0.55 |
| 0.3 |
All other filters |
S2 (SW) |
514.0 |
513.0 |
2 |
813 |
0.55 |
| 0.6 |
SZ |
S2 (SW) |
514.8 |
515.0 |
4 |
813 |
0.55 |
| 0.6 |
H |
S2 (SW) |
514.0 |
514.5 |
4 |
813 |
0.55 |
| 0.6 |
NB_1.06 |
S2 (SW) |
514.1 |
515.0 |
4 |
813 |
0.55 |
| 0.6 |
NB_1.08 |
S2 (SW) |
514.4 |
515.0 |
4 |
813 |
0.55 |
| 0.6 |
NB_1.64 |
S2 (SW) |
514.1 |
515.0 |
4 |
813 |
0.55 |
| 0.6 |
NB_2.29 |
S2 (SW) |
514.0 |
514.5 |
4 |
813 |
0.55 |
| 0.6 |
NB_2.09 & NB_2.13 |
S2 (SW) |
514.3 |
514.0 |
4 |
813 |
0.55 |
| 0.6 |
All other filters |
S2 (SW) |
514.3 |
515.0 |
4 |
813 |
0.55 |
| 0.8 |
SZ |
S2 (SW) |
517.0 |
510.5 |
5.4 |
814 |
0.55 |
| 0.8 |
H |
S2 (SW) |
516.2 |
510.0 |
5.4 |
814 |
0.55 |
| 0.8 |
NB_1.06 |
S2 (SW) |
516.3 |
510.5 |
5.4 |
814 |
0.55 |
| 0.8 |
NB_1.08 |
S2 (SW) |
516.6 |
510.5 |
5.4 |
814 |
0.55 |
| 0.8 |
NB_1.64 |
S2 (SW) |
516.3 |
510.5 |
5.4 |
814 |
0.55 |
| 0.8 |
NB_2.29 |
S2 (SW) |
516.2 |
510.0 |
5.4 |
814 |
0.55 |
| 0.8 |
NB_2.09 & NB_2.13 |
S2 (SW) |
516.5 |
509.5 |
5.4 |
814 |
0.55 |
| 0.8 |
All other filters |
S2 (SW) |
516.5 |
510.5 |
5.4 |
814 |
0.55 |
| 1.0 |
SZ |
S2 (SW) |
515.0 |
517.5 |
6.8 |
812 |
0.55 |
| 1.0 |
H |
S2 (SW) |
514.2 |
517.0 |
6.8 |
812 |
0.55 |
| 1.0 |
NB_1.06 |
S2 (SW) |
514.3 |
517.5 |
6.8 |
812 |
0.55 |
| 1.0 |
NB_1.08 |
S2 (SW) |
514.6 |
517.5 |
6.8 |
812 |
0.55 |
| 1.0 |
NB_1.64 |
S2 (SW) |
514.3 |
517.5 |
6.8 |
812 |
0.55 |
| 1.0 |
NB_2.29 |
S2 (SW) |
514.2 |
517.0 |
6.8 |
812 |
0.55 |
| 1.0 |
NB_2.09 & NB_2.13 |
S2 (SW) |
514.5 |
516.5 |
6.8 |
812 |
0.55 |
| 1.0 |
All other filters |
S2 (SW) |
514.5 |
517.5 |
6.8 |
812 |
0.55 |
| 1.5 |
All filters |
S2 (SW) |
515.0 |
515.5 |
10.2 |
812 |
0.55 |
| 2.0 |
All filters |
S2 (SW) |
515.0 |
515.5 |
13.6 |
812 |
0.55 |
| 0.3 |
NB_3.21 |
L2 (LW) |
509.1 |
516.0 |
2 |
817 |
0.32 |
| 0.3 |
NB_3.28 |
L2 (LW) |
509.1 |
516.0 |
2 |
817 |
0.32 |
| 0.3 |
NB_3.80 |
L2 (LW) |
510.7 |
515.5 |
2 |
817 |
0.32 |
| 0.3 |
NB_4.07 |
L2 (LW) |
510.1 |
515.0 |
2 |
817 |
0.32 |
| 0.3 |
L |
L2 (LW) |
510.1 |
517.5 |
2 |
817 |
0.32 |
| 0.3 |
M_NB |
L2 (LW) |
506.9 |
515.5 |
2 |
817 |
0.32 |
| 0.3 |
J+Block |
L2 (LW) |
509.2 |
516.5 |
2 |
817 |
0.32 |
| 0.3 |
H |
L2 (LW) |
509.6 |
517.0 |
2 |
817 |
0.32 |
| 0.3 |
Ks |
L2 (LW) |
509.2 |
516.0 |
2 |
817 |
0.32 |
| 0.6 |
NB_3.21 |
L2 (LW) |
509.5 |
517.5 |
4 |
816 |
0.32 |
| 0.6 |
NB_3.28 |
L2 (LW) |
509.5 |
517.5 |
4 |
816 |
0.32 |
| 0.6 |
NB_3.80 |
L2 (LW) |
511.1 |
518.0 |
4 |
816 |
0.32 |
| 0.6 |
NB_4.07 |
L2 (LW) |
510.5 |
516.5 |
4 |
816 |
0.32 |
| 0.6 |
L |
L2 (LW) |
510.5 |
519.0 |
4 |
816 |
0.32 |
| 0.6 |
M_NB |
L2 (LW) |
507.3 |
517.0 |
4 |
816 |
0.32 |
| 0.6 |
J+Block |
L2 (LW) |
509.6 |
518.0 |
4 |
816 |
0.32 |
| 0.6 |
H |
L2 (LW) |
510.0 |
518.5 |
4 |
816 |
0.32 |
| 0.6 |
Ks |
L2 (LW) |
509.6 |
517.5 |
4 |
816 |
0.32 |
| 0.8 |
NB_3.21 |
L2 (LW) |
511.7 |
513.0 |
5.4 |
817 |
0.32 |
| 0.8 |
NB_3.28 |
L2 (LW) |
511.7 |
513.0 |
5.4 |
817 |
0.32 |
| 0.8 |
NB_3.80 |
L2 (LW) |
513.3 |
513.5 |
5.4 |
817 |
0.32 |
| 0.8 |
NB_4.07 |
L2 (LW) |
512.7 |
512.0 |
5.4 |
817 |
0.32 |
| 0.8 |
L |
L2 (LW) |
512.7 |
514.5 |
5.4 |
817 |
0.32 |
| 0.8 |
M_NB |
L2 (LW) |
509.5 |
512.5 |
5.4 |
817 |
0.32 |
| 0.8 |
J+Block |
L2 (LW) |
511.8 |
513.5 |
5.4 |
817 |
0.32 |
| 0.8 |
H |
L2 (LW) |
512.2 |
514.0 |
5.4 |
817 |
0.32 |
| 0.8 |
Ks |
L2 (LW) |
511.8 |
513.0 |
5.4 |
817 |
0.32 |
| 1.0 |
NB_3.21 |
L2 (LW) |
509.6 |
519.5 |
6.8 |
816 |
0.32 |
| 1.0 |
NB_3.28 |
L2 (LW) |
509.6 |
519.5 |
6.8 |
816 |
0.32 |
| 1.0 |
NB_3.80 |
L2 (LW) |
511.3 |
520.0 |
6.8 |
816 |
0.32 |
| 1.0 |
NB_4.07 |
L2 (LW) |
510.6 |
518.5 |
6.8 |
816 |
0.32 |
| 1.0 |
L |
L2 (LW) |
510.6 |
521.0 |
6.8 |
816 |
0.32 |
| 1.0 |
M_NB |
L2 (LW) |
507.4 |
519.0 |
6.8 |
816 |
0.32 |
| 1.0 |
J+Block |
L2 (LW) |
509.7 |
520.0 |
6.8 |
816 |
0.32 |
| 1.0 |
H |
L2 (LW) |
510.1 |
520.5 |
6.8 |
816 |
0.32 |
| 1.0 |
Ks |
L2 (LW) |
509.7 |
519.5 |
6.8 |
816 |
0.32 |
| 1.5 |
NB_3.21 |
L2 (LW) |
510.4 |
508.5 |
10.2 |
816 |
0.32 |
| 1.5 |
NB_3.28 |
L2 (LW) |
510.4 |
508.5 |
10.2 |
816 |
0.32 |
| 1.5 |
NB_3.80 |
L2 (LW) |
512.1 |
508.5 |
10.2 |
816 |
0.32 |
| 1.5 |
NB_4.07 |
L2 (LW) |
511.4 |
507.5 |
10.2 |
816 |
0.32 |
| 1.5 |
L |
L2 (LW) |
511.4 |
510.0 |
10.2 |
816 |
0.32 |
| 1.5 |
M_NB |
L2 (LW) |
508.2 |
508.0 |
10.2 |
816 |
0.32 |
| 1.5 |
J+Block |
L2 (LW) |
510.5 |
509.0 |
10.2 |
816 |
0.32 |
| 1.5 |
H |
L2 (LW) |
510.9 |
509.5 |
10.2 |
816 |
0.32 |
| 1.5 |
Ks |
L2 (LW) |
510.5 |
508.5 |
10.2 |
816 |
0.32 |
| 2.0 |
NB_3.21 |
L2 (LW) |
510.2 |
518.0 |
13.6 |
815 |
0.32 |
| 2.0 |
NB_3.28 |
L2 (LW) |
510.2 |
518.0 |
13.6 |
815 |
0.32 |
| 2.0 |
NB_3.80 |
L2 (LW) |
511.8 |
519.0 |
13.6 |
815 |
0.32 |
| 2.0 |
NB_4.07 |
L2 (LW) |
511.2 |
517.0 |
13.6 |
815 |
0.32 |
| 2.0 |
L |
L2 (LW) |
511.2 |
519.5 |
13.6 |
815 |
0.32 |
| 2.0 |
M_NB |
L2 (LW) |
508.0 |
517.5 |
13.6 |
815 |
0.32 |
| 2.0 |
J+Block |
L2 (LW) |
510.3 |
518.5 |
13.6 |
815 |
0.32 |
| 2.0 |
H |
L2 (LW) |
510.7 |
519.0 |
13.6 |
815 |
0.32 |
| 2.0 |
Ks |
L2 (LW) |
510.3 |
518.0 |
13.6 |
815 |
0.32 |
Observations from June 25 2002 - March 26 2003
| Slit | Filter | Objective (Arm) | X center | Ycenter | Width | Length | Tilt |
| 0.3 |
SZ |
S2 (SW) |
513.5 |
512.5 |
2 |
813 |
0.55 |
| 0.3 |
H |
S2 (SW) |
513.7 |
512.5 |
2 |
813 |
0.55 |
| 0.3 |
NB_1.06 |
S2 (SW) |
513.8 |
513.0 |
2 |
813 |
0.55 |
| 0.3 |
NB_1.08 | S2 (SW) |
514.1 |
513.0 |
2 |
813 |
0.55 |
| 0.3 |
NB_1.64 |
S2 (SW) |
513.8 |
513.0 |
2 |
813 |
0.55 |
| 0.3 |
NB_2.29 |
S2 (SW) |
513.7 |
512.5 |
2 |
813 |
0.55 |
| 0.3 |
NB_2.09 & NB_2.13 |
S2 (SW) |
514.0 |
512.0 |
2 |
813 |
0.55 |
| 0.3 |
All other filters |
S2 (SW) |
514.0 |
513.0 |
2 |
813 |
0.55 |
| 0.6 |
SZ |
S2 (SW) |
514.8 |
515.0 |
4 |
813 |
0.55 |
| 0.6 |
H |
S2 (SW) |
514.0 |
514.5 |
4 |
813 |
0.55 |
| 0.6 |
NB_1.06 |
S2 (SW) |
514.1 |
515.0 |
4 |
813 |
0.55 |
| 0.6 |
NB_1.08 |
S2 (SW) |
514.4 |
515.0 |
4 |
813 |
0.55 |
| 0.6 |
NB_1.64 |
S2 (SW) |
514.1 |
515.0 |
4 |
813 |
0.55 |
| 0.6 |
NB_2.29 |
S2 (SW) |
514.0 |
514.5 |
4 |
813 |
0.55 |
| 0.6 |
NB_2.09 & NB_2.13 |
S2 (SW) |
514.3 |
514.0 |
4 |
813 |
0.55 |
| 0.6 |
All other filters |
S2 (SW) |
514.3 |
515.0 |
4 |
813 |
0.55 |
| 1.0 |
SZ |
S2 (SW) |
515.0 |
517.5 |
6.8 |
812 |
0.55 |
| 1.0 |
H |
S2 (SW) |
514.2 |
517.0 |
6.8 |
812 |
0.55 |
| 1.0 |
NB_1.06 |
S2 (SW) |
514.3 |
517.5 |
6.8 |
812 |
0.55 |
| 1.0 |
NB_1.08 |
S2 (SW) |
514.6 |
517.5 |
6.8 |
812 |
0.55 |
| 1.0 |
NB_1.64 |
S2 (SW) |
514.3 |
517.5 |
6.8 |
812 |
0.55 |
| 1.0 |
NB_2.29 |
S2 (SW) |
514.2 |
517.0 |
6.8 |
812 |
0.55 |
| 1.0 |
NB_2.09 & NB_2.13 |
S2 (SW) |
514.5 |
516.5 |
6.8 |
812 |
0.55 |
| 1.0 |
All other filters |
S2 (SW) |
514.5 |
517.5 |
6.8 |
812 |
0.55 |
| 2.0 |
All filters |
S2 (SW) |
515.0 |
515.5 |
13.6 |
812 |
0.55 |
| 0.3 |
NB_3.21 |
L2 (LW) |
509.1 |
516.0 |
2 |
817 |
0.23 |
| 0.3 |
NB_3.28 |
L2 (LW) |
509.1 |
516.0 |
2 |
817 |
0.23 |
| 0.3 |
NB_4.07 |
L2 (LW) |
510.1 |
515.0 |
2 |
815 |
0.23 |
| 0.3 |
L |
L2 (LW) |
510.1 |
517.5 |
2 |
815 |
0.23 |
| 0.3 |
M_NB |
L2 (LW) |
506.9 |
515.5 |
2 |
815 |
0.23 |
| 0.3 |
J+Block |
L2 (LW) |
509.2 |
516.5 |
2 |
815 |
0.23 |
| 0.3 |
H |
L2 (LW) |
509.6 |
517.0 |
2 |
815 |
0.23 |
| 0.3 |
Ks |
L2 (LW) |
509.2 |
516.0 |
2 |
815 |
0.23 |
| 0.6 |
NB_3.21 |
L2 (LW) |
509.5 |
517.5 |
4 |
816 |
0.23 |
| 0.6 |
NB_3.28 |
L2 (LW) |
509.5 |
517.5 |
4 |
816 |
0.23 |
| 0.6 |
NB_4.07 |
L2 (LW) |
510.5 |
516.5 |
4 |
816 |
0.23 |
| 0.6 |
L |
L2 (LW) |
510.5 |
519.0 |
4 |
816 |
0.23 |
| 0.6 |
M_NB |
L2 (LW) |
507.3 |
517.0 |
4 |
816 |
0.23 |
| 0.6 |
J+Block |
L2 (LW) |
509.6 |
518.0 |
4 |
816 |
0.23 |
| 0.6 |
H |
L2 (LW) |
510.0 |
518.5 |
4 |
816 |
0.23 |
| 0.6 |
Ks |
L2 (LW) |
509.6 |
517.5 |
4 |
816 |
0.23 |
| 1.0 |
NB_3.21 |
L2 (LW) |
509.6 |
519.5 |
6.8 |
816 |
0.23 |
| 1.0 |
NB_3.28 |
L2 (LW) |
509.6 |
519.5 |
6.8 |
816 |
0.23 |
| 1.0 |
NB_4.07 |
L2 (LW) |
510.6 |
518.5 |
6.8 |
816 |
0.23 |
| 1.0 |
L |
L2 (LW) |
510.6 |
521.0 |
6.8 |
816 |
0.23 |
| 1.0 |
M_NB |
L2 (LW) |
507.4 |
519.0 |
6.8 |
816 |
0.23 |
| 1.0 |
J+Block |
L2 (LW) |
509.7 |
520.0 |
6.8 |
816 |
0.23 |
| 1.0 |
H |
L2 (LW) |
510.1 |
520.5 |
6.8 |
816 |
0.23 |
| 1.0 |
Ks |
L2 (LW) |
509.7 |
519.5 |
6.8 |
816 |
0.23 |
| 2.0 |
NB_3.21 |
L2 (LW) |
510.2 |
518.0 |
13.6 |
815 |
0.23 |
| 2.0 |
NB_3.28 |
L2 (LW) |
510.2 |
518.0 |
13.6 |
815 |
0.23 |
| 2.0 |
NB_4.07 |
L2 (LW) |
511.2 |
517.0 |
13.6 |
815 |
0.23 |
| 2.0 |
L |
L2 (LW) |
511.2 |
519.5 |
13.6 |
815 |
0.23 |
| 2.0 |
M_NB |
L2 (LW) |
508.0 |
517.5 |
13.6 |
815 |
0.23 |
| 2.0 |
J+Block |
L2 (LW) |
510.3 |
518.5 |
13.6 |
815 |
0.23 |
| 2.0 |
H |
L2 (LW) |
510.7 |
519.0 |
13.6 |
815 |
0.23 |
| 2.0 |
Ks |
L2 (LW) |
510.3 |
518.0 |
13.6 |
815 |
0.23 |
Observations from April 22 - June 24 2002
| Slit | Filter | Objective (Arm) | X center | Ycenter | Width | Length | Tilt |
| 0.3 |
H |
S2 (SW) |
520.3 |
509.5 |
2 |
812 |
0.55 |
| 0.3 |
J |
S2 (SW) |
521.0 |
512.0 |
2 |
812 |
0.55 |
| 0.3 |
SZ |
S2 (SW) |
521.0 |
509.5 |
2 |
812 |
0.55 |
| 0.3 |
NB_1.06 |
S2 (SW) |
520.3 |
509.5 |
2 |
812 |
0.55 |
| 0.3 |
NB_2.29 |
S2 (SW) |
520.3 |
509.5 |
2 |
812 |
0.55 |
| 0.3 |
NB_1.64 |
S2 (SW) |
520.3 |
509.5 |
2 |
812 |
0.55 |
| 0.3 |
All other filters |
S2 (SW) |
520.7 |
509.5 |
2 |
812 |
0.55 |
| 0.6 |
H |
S2 (SW) |
520..8 |
512.0 |
4 |
813 |
0.55 |
| 0.6 |
J |
S2 (SW) |
521.0 |
512.0 |
4 |
813 |
0.55 |
| 0.6 |
SZ |
S2 (SW) |
521.5 |
512.0 |
4 |
813 |
0.55 |
| 0.6 |
NB_1.06 |
S2 (SW) |
520.8 |
512.0 |
4 |
813 |
0.55 |
| 0.6 |
NB_2.29 |
S2 (SW) |
520.8 |
512.0 |
4 |
813 |
0.55 |
| 0.6 |
NB_1.64 |
S2 (SW) |
520.8 |
512.0 |
4 |
813 |
0.55 |
| 0.6 |
All other filters |
S2 (SW) |
521.2 |
512.0 |
4 |
813 |
0.55 |
| 1.0 |
H |
S2 (SW) |
520.9 |
516.0 |
6.8 |
813 |
0.55 |
| 1.0 |
J |
S2 (SW) |
521.1 |
516.0 |
6.8 |
813 |
0.55 |
| 1.0 |
SZ |
S2 (SW) |
521.6 |
516.0 |
6.8 |
813 |
0.55 |
| 1.0 |
NB_1.06 |
S2 (SW) |
520.9 |
516.0 |
6.8 |
813 |
0.55 |
| 1.0 |
NB_2.29 |
S2 (SW) |
521.6 |
516.0 |
6.8 |
813 |
0.55 |
| 1.0 |
NB_1.64 |
S2 (SW) |
521.6 |
516.0 |
6.8 |
813 |
0.55 |
| 1.0 |
All other filters |
S2 (SW) |
520.8 |
512.0 |
6.8 |
813 |
0.55 |
| 2.0 |
All filters |
S2 (SW) |
521.9 |
513.0 |
6.8 |
813 |
0.55 |
| 0.3 |
NB_3.21 |
L2 (LW) |
510.6 |
515.5 |
2 |
815 |
0.16 |
| 0.3 |
NB_3.28 |
L2 (LW) |
510.6 |
515.5 |
2 |
815 |
0.16 |
| 0.3 |
NB_3.80 |
L2 (LW) |
512.3 |
515.5 |
2 |
815 |
0.16 |
| 0.3 |
NB_4.07 |
L2 (LW) |
511.6 |
515.5 |
2 |
815 |
0.16 |
| 0.3 |
L |
L2 (LW) |
511.5 |
515.5 |
2 |
815 |
0.16 |
| 0.3 |
M_NB |
L2 (LW) |
508.5 |
515.5 |
2 |
815 |
0.16 |
| 0.3 |
J+Block |
L2 (LW) |
511.0 |
515.5 |
2 |
815 |
0.16 |
| 0.3 |
H |
L2 (LW) |
511.5 |
515.5 |
2 |
815 |
0.16 |
| 0.3 |
Ks |
L2 (LW) |
510.7 |
515.5 |
2 |
815 |
0.16 |
| 0.6 |
NB_3.21 |
L2 (LW) |
511.1 |
516.0 |
4 |
815 |
0.16 |
| 0.6 |
NB_3.28 |
L2 (LW) |
511.1 |
516.0 |
4 |
815 |
0.16 |
| 0.6 |
NB_3.80 |
L2 (LW) |
512.8 |
516.0 |
4 |
815 |
0.16 |
| 0.6 |
NB_4.07 |
L2 (LW) |
512.1 |
516.0 |
4 |
815 |
0.16 |
| 0.6 |
L |
L2 (LW) |
512.0 |
516.0 |
4 |
815 |
0.16 |
| 0.6 |
M_NB |
L2 (LW) |
509.0 |
516.0 |
4 |
815 |
0.16 |
| 0.6 |
J+Block |
L2 (LW) |
511.5 |
516.0 |
4 |
815 |
0.16 |
| 0.6 |
H |
L2 (LW) |
512.0 |
516.0 |
4 |
815 |
0.16 |
| 0.6 |
Ks |
L2 (LW) |
511.2 |
516.0 |
4 |
815 |
0.16 |
| 1.0 |
NB_3.21 |
L2 (LW) |
511.2 |
520.0 |
6.8 |
815 |
0.16 |
| 1.0 |
NB_3.28 |
L2 (LW) |
511.2 |
520.0 |
6.8 |
815 |
0.16 |
| 1.0 |
NB_3.80 |
L2 (LW) |
512.9 |
520.0 |
6.8 |
815 |
0.16 |
| 1.0 |
NB_4.07 |
L2 (LW) |
512.2 |
520.0 |
6.8 |
815 |
0.16 |
| 1.0 |
L |
L2 (LW) |
512.1 |
520.0 |
6.8 |
815 |
0.16 |
| 1.0 |
M_NB |
L2 (LW) |
509.1 |
520.0 |
6.8 |
815 |
0.16 |
| 1.0 |
J+Block |
L2 (LW) |
511.6 |
520.0 |
6.8 |
815 |
0.16 |
| 1.0 |
H |
L2 (LW) |
512.1 |
510.0 |
6.8 |
815 |
0.16 |
| 1.0 |
Ks |
L2 (LW) |
511.3 |
520.0 |
6.8 |
815 |
0.16 |
| 2.0 |
NB_3.21 |
L2 (LW) |
511.8 |
518.0 |
13.6 |
815 |
0.16 |
| 2.0 |
NB_3.28 |
L2 (LW) |
511.8 |
518.0 |
13.6 |
815 |
0.16 |
| 2.0 |
NB_3.80 |
L2 (LW) |
513.5 |
518.0 |
13.6 |
815 |
0.16 |
| 2.0 |
NB_4.07 |
L2 (LW) |
512.8 |
518.0 |
13.6 |
815 |
0.16 |
| 2.0 |
L |
L2 (LW) |
512.7 |
518.0 |
13.6 |
815 |
0.16 |
| 2.0 |
M_NB |
L2 (LW) |
509.7 |
518.0 |
13.6 |
815 |
0.16 |
| 2.0 |
J+Block |
L2 (LW) |
512.2 |
518.0 |
13.6 |
815 |
0.16 |
| 2.0 |
H |
L2 (LW) |
512.7 |
518.0 |
13.6 |
815 |
0.16 |
| 2.0 |
Ks |
L2 (LW) |
511.9 |
518.0 |
13.6 |
815 |
0.16 |
Observations from March 14 - April 21 2002.
| Slit | Filter | Objective (Arm) | X center | Ycenter | Width | Length | Tilt |
| 0.3 | H | S2 (SW) | 520.3 | 495.5 | 2 | 813 | 0.55 |
| 0.3 | J | S2 (SW) | 520.5 | 495.5 | 2 | 813 | 0.55 |
| 0.3 | SZ | S2 (SW) | 521.0 | 495.5 | 2 | 813 | 0.55 |
| 0.3 | NB_1.06 | S2 (SW) | 520.3 | 495.5 | 2 | 813 | 0.55 |
| 0.3 | NB_2.29 | S2 (SW) | 520.3 | 495.5 | 2 | 813 | 0.55 |
| 0.3 | NB_1.64 | S2 (SW) | 520.3 | 495.5 | 2 | 813 | 0.55 |
| 0.3 | All other filters | S2 (SW) | 520.7 | 495.5 | 2 | 813 | 0.55 |
| 0.6 | H | S2 (SW) | 520.8 | 496 | 4 | 813 | 0.55 |
| 0.6 | J | S2 (SW) | 521.0 | 496 | 4 | 813 | 0.55 |
| 0.6 | SZ | S2 (SW) | 521.5 | 496 | 4 | 813 | 0.55 |
| 0.6 | NB_1.06 | S2 (SW) | 520.8 | 496 | 4 | 813 | 0.55 |
| 0.6 | NB_2.29 | S2 (SW) | 520.8 | 496 | 4 | 813 | 0.55 |
| 0.6 | NB_1.64 | S2 (SW) | 520.8 | 496 | 4 | 813 | 0.55 |
| 0.6 | All other filters | S2 (SW) | 521.2 | 496 | 4 | 813 | 0.55 |
| 1.0 | H | S2 (SW) | 520.9 | 501 | 6.8 | 813 | 0.55 |
| 1.0 | J | S2 (SW) | 521.1 | 501 | 6.8 | 813 | 0.55 |
| 1.0 | SZ | S2 (SW) | 521.6 | 501 | 6.8 | 813 | 0.55 |
| 1.0 | NB_1.06 | S2 (SW) | 520.9 | 501 | 6.8 | 813 | 0.55 |
| 1.0 | NB_2.29 | S2 (SW) | 521.6 | 501 | 6.8 | 813 | 0.55 |
| 1.0 | NB_1.64 | S2 (SW) | 521.6 | 501 | 6.8 | 813 | 0.55 |
| 1.0 | All other filters | S2 (SW) | 521.3 | 501 | 6.8 | 813 | 0.55 |
| 2.0 | All filters | S2 (SW) | 521.9 | 499 | 13.6 | 811 | 0.55 |
| 0.3 | NB_3.21 | L2 (LW) | 510.6 | 506.5 | 2 | 817 | 0.16 |
| 0.3 | NB_3.28 | L2 (LW) | 510.6 | 506.5 | 2 | 817 | 0.16 |
| 0.3 | NB_3.80 | L2 (LW) | 512.3 | 506.5 | 2 | 817 | 0.16 |
| 0.3 | NB_4.07 | L2 (LW) | 511.6 | 505.5 | 2 | 817 | 0.16 |
| 0.3 | L | L2 (LW) | 511.5 | 506 | 2 | 818 | 0.16 |
| 0.3 | NB_M | L2 (LW) | 508.5 | 506 | 2 | 818 | 0.16 |
| 0.3 | J+Block | L2 (LW) | 511.0 | 507 | 2 | 819 | 0.16 |
| 0.3 | H | L2 (LW) | 511.5 | 507.5 | 2 | 817 | 0.16 |
| 0.3 | Ks | L2 (LW) | 510.7 | 506.5 | 2 | 817 | 0.16 |
| 0.6 | NB_3.21 | L2 (LW) | 511.1 | 507 | 4 | 817 | 0.16 |
| 0.6 | NB_3.28 | L2 (LW) | 511.1 | 507 | 4 | 817 | 0.16 |
| 0.6 | NB_3.80 | L2 (LW) | 512.8 | 507 | 4 | 817 | 0.16 |
| 0.6 | NB_4.07 | L2 (LW) | 512.1 | 507 | 4 | 817 | 0.16 |
| 0.6 | L | L2 (LW) | 512.0 | 507 | 4 | 817 | 0.16 |
| 0.6 | NB_M | L2 (LW) | 509.0 | 507 | 4 | 817 | 0.16 |
| 0.6 | J+Block | L2 (LW) | 511.5 | 507 | 4 | 817 | 0.16 |
| 0.6 | H | L2 (LW) | 512.0 | 507 | 4 | 817 | 0.16 |
| 0.6 | Ks | L2 (LW) | 511.2 | 507 | 4 | 817 | 0.16 |
| 1.0 | NB_3.21 | L2 (LW) | 511.2 | 511 | 6.8 | 816 | 0.16 |
| 1.0 | NB_3.28 | L2 (LW) | 511.2 | 511 | 6.8 | 816 | 0.16 |
| 1.0 | NB_3.80 | L2 (LW) | 512.9 | 507 | 6.8 | 817 | 0.16 |
| 1.0 | NB_4.07 | L2 (LW) | 512.2 | 511 | 6.8 | 816 | 0.16 |
| 1.0 | L | L2 (LW) | 512.1 | 511 | 6.8 | 816 | 0.16 |
| 1.0 | NB_M | L2 (LW) | 509.1 | 511 | 6.8 | 816 | 0.16 |
| 1.0 | J+Block | L2 (LW) | 511.6 | 511 | 6.8 | 816 | 0.16 |
| 1.0 | H | L2 (LW) | 512.1 | 511 | 6.8 | 816 | 0.16 |
| 1.0 | Ks | L2 (LW) | 511.3 | 511 | 6.8 | 816 | 0.16 |
| 2.0 | NB_3.21 | L2 (LW) | 511.8 | 509 | 13.6 | 815 | 0.16 |
| 2.0 | NB_3.28 | L2 (LW) | 511.8 | 509 | 13.6 | 815 | 0.16 |
| 2.0 | NB_3.80 | L2 (LW) | 513.5 | 509 | 13.6 | 815 | 0.16 |
| 2.0 | NB_4.07 | L2 (LW) | 512.8 | 509 | 13.6 | 815 | 0.16 |
| 2.0 | L | L2 (LW) | 512.7 | 508 | 13.6 | 815 | 0.16 |
| 2.0 | NB_M | L2 (LW) | 509.7 | 509 | 13.6 | 815 | 0.16 |
| 2.0 | J+Block | L2 (LW) | 512.2 | 509 | 13.6 | 815 | 0.16 |
| 2.0 | H | L2 (LW) | 512.7 | 509 | 13.6 | 815 | 0.16 |
| 2.0 | Ks | L2 (LW) | 511.9 | 509 | 13.6 | 815 | 0.16 |
Observations taken between October 14th 2001 - March 13, 2002
| Slit | Filter | Objective (Arm) | X center | Ycenter | Width | Length | Tilt |
| 0.3 | H | S2 (SW) | 520.3 | 495.5 | 2 | 814 | 0.55 |
| 0.3 | J | S2 (SW) | 520.5 | 495.5 | 2 | 814 | 0.55 |
| 0.3 | SZ | S2 (SW) | 521.1 | 495.5 | 2 | 814 | 0.55 |
| 0.3 | NB_1.06 | S2 (SW) | 520.3 | 495.5 | 2 | 814 | 0.55 |
| 0.3 | NB_2.29 | S2 (SW) | 520.3 | 495.5 | 2 | 814 | 0.55 |
| 0.3 | NB_1.64 | S2 (SW) | 520.3 | 495.5 | 2 | 814 | 0.55 |
| 0.3 | All other filters | S2 (SW) | 520.6 | 495.5 | 2 | 814 | 0.55 |
| 0.6 | H | S2 (SW) | 520.8 | 497 | 4 | 813 | 0.55 |
| 0.6 | J | S2 (SW) | 521 | 497 | 4 | 813 | 0.55 |
| 0.6 | SZ | S2 (SW) | 521.6 | 497 | 4 | 813 | 0.55 |
| 0.6 | NB_1.06 | S2 (SW) | 520.8 | 497 | 4 | 813 | 0.55 |
| 0.6 | NB_2.29 | S2 (SW) | 520.8 | 497 | 4 | 813 | 0.55 |
| 0.6 | NB_1.64 | S2 (SW) | 520.8 | 497 | 4 | 813 | 0.55 |
| 0.6 | All other filters | S2 (SW) | 521.1 | 497 | 4 | 813 | 0.55 |
| 1.0 | H | S2 (SW) | 521.6 | 500 | 6.8 | 813 | 0.55 |
| 1.0 | J | S2 (SW) | 521.8 | 500 | 6.8 | 813 | 0.55 |
| 1.0 | SZ | S2 (SW) | 522.5 | 500 | 6.8 | 813 | 0.55 |
| 1.0 | NB_1.06 | S2 (SW) | 521.6 | 500 | 6.8 | 813 | 0.55 |
| 1.0 | NB_2.29 | S2 (SW) | 521.6 | 500 | 6.8 | 813 | 0.55 |
| 1.0 | NB_1.64 | S2 (SW) | 521.6 | 500 | 6.8 | 813 | 0.55 |
| 1.0 | All other filters | S2 (SW) | 521.9 | 500 | 6.8 | 813 | 0.55 |
| 2.0 | All filters | S2 (SW) | 522.0 | 498 | 13.6 | 811 | 0.55 |
| 0.3 | NB_3.21 | L2 (LW) | 528.7 | 508 | 2 | 817 | 0.66 |
| 0.3 | NB_3.28 | L2 (LW) | 528.7 | 508 | 2 | 817 | 0.66 |
| 0.3 | NB_4.07 | L2 (LW) | 529.8 | 508 | 2 | 817 | 0.66 |
| 0.3 | L | L2 (LW) | 529.8 | 508 | 2 | 817 | 0.66 |
| 0.3 | NB_M | L2 (LW) | 526.9 | 508 | 2 | 818 | 0.66 |
| 0.3 | J+Block | L2 (LW) | 529.1 | 508 | 2 | 817 | 0.66 |
| 0.3 | H | L2 (LW) | 529.5 | 508 | 2 | 817 | 0.66 |
| 0.3 | Ks | L2 (LW) | 528.9 | 508 | 2 | 817 | 0.66 |
| 0.6 | NB_3.21 | L2 (LW) | 529.1 | 507 | 4 | 817 | 0.66 |
| 0.6 | NB_3.28 | L2 (LW) | 529.1 | 507 | 4 | 817 | 0.66 |
| 0.6 | NB_4.07 | L2 (LW) | 530.2 | 507 | 4 | 817 | 0.66 |
| 0.6 | L | L2 (LW) | 530.2 | 507 | 4 | 817 | 0.66 |
| 0.6 | NB_M | L2 (LW) | 527.3 | 507 | 4 | 817 | 0.66 |
| 0.6 | J+Block | L2 (LW) | 529.5 | 507 | 4 | 817 | 0.66 |
| 0.6 | H | L2 (LW) | 529.9 | 507 | 4 | 817 | 0.66 |
| 0.6 | Ks | L2 (LW) | 529.3 | 507 | 4 | 817 | 0.66 |
| 1.0 | NB_3.21 | L2 (LW) | 529.7 | 511 | 6.8 | 816 | 0.66 |
| 1.0 | NB_3.28 | L2 (LW) | 529.7 | 511 | 6.8 | 816 | 0.66 |
| 1.0 | NB_4.07 | L2 (LW) | 530.8 | 511 | 6.8 | 816 | 0.66 |
| 1.0 | L | L2 (LW) | 530.8 | 511 | 6.8 | 816 | 0.66 |
| 1.0 | NB_M | L2 (LW) | 527.9 | 511 | 6.8 | 816 | 0.66 |
| 1.0 | J+Block | L2 (LW) | 530.1 | 511 | 6.8 | 816 | 0.66 |
| 1.0 | H | L2 (LW) | 530.5 | 511 | 6.8 | 816 | 0.66 |
| 1.0 | Ks | L2 (LW) | 529.9 | 511 | 6.8 | 816 | 0.66 |
| 2.0 | NB_3.21 | L2 (LW) | 529.8 | 509 | 13.6 | 815 | 0.66 |
| 2.0 | NB_3.28 | L2 (LW) | 529.8 | 509 | 13.6 | 815 | 0.66 |
| 2.0 | NB_4.07 | L2 (LW) | 530.9 | 509 | 13.6 | 815 | 0.66 |
| 2.0 | L | L2 (LW) | 530.9 | 508 | 13.6 | 815 | 0.66 |
| 2.0 | NB_M | L2 (LW) | 528.0 | 509 | 13.6 | 815 | 0.66 |
| 2.0 | J+Block | L2 (LW) | 530.2 | 509 | 13.6 | 815 | 0.66 |
| 2.0 | H | L2 (LW) | 530.6 | 509 | 13.6 | 815 | 0.66 |
| 2.0 | Ks | L2 (LW) | 530.0 | 509 | 13.6 | 815 | 0.66 |
Observations taken between August 20th - October 14th, 2001 (note thatthe table of slit positions that was sent out to service mode users is incorrect):
| Slit | Filter | Objective (Arm) | X center | Ycenter | Width | Length | Tilt |
| 0.3 | H | S2 (SW) | 520.6 | 494 | 2 | 813 | 0.55 |
| 0.3 | J | S2 (SW) | 520.7 | 494 | 2 | 813 | 0.55 |
| 0.3 | SZ | S2 (SW) | 521.3 | 494 | 2 | 813 | 0.55 |
| 0.3 | NB_1.06 | S2 (SW) | 520.6 | 494 | 2 | 813 | 0.55 |
| 0.3 | NB_2.29 | S2 (SW) | 520.7 | 494 | 2 | 813 | 0.55 |
| 0.3 | NB_1.64 | S2 (SW) | 520.6 | 494 | 2 | 813 | 0.55 |
| 0.3 | All other filters | S2 (SW) | 520.9 | 494 | 2 | 813 | 0.55 |
| 0.6 | H | S2 (SW) | 520.3 | 496 | 4 | 813 | 0.55 |
| 0.6 | J | S2 (SW) | 520.4 | 496 | 4 | 813 | 0.55 |
| 0.6 | SZ | S2 (SW) | 521.2 | 496 | 4 | 813 | 0.55 |
| 0.6 | NB_1.06 | S2 (SW) | 520.3 | 496 | 4 | 813 | 0.55 |
| 0.6 | NB_2.29 | S2 (SW) | 520.4 | 496 | 4 | 813 | 0.55 |
| 0.6 | NB_1.64 | S2 (SW) | 520.3 | 496 | 4 | 813 | 0.55 |
| 0.6 | All other filters | S2 (SW) | 520.6 | 496 | 4 | 813 | 0.55 |
| 1.0 | H | S2 (SW) | 519.9 | 496 | 6.8 | 813 | 0.55 |
| 1.0 | J | S2 (SW) | 520.0 | 496 | 6.8 | 813 | 0.55 |
| 1.0 | SZ | S2 (SW) | 520.6 | 496 | 6.8 | 813 | 0.55 |
| 1.0 | NB_1.06 | S2 (SW) | 519.9 | 496 | 6.8 | 813 | 0.55 |
| 1.0 | NB_2.29 | S2 (SW) | 520.0 | 496 | 6.8 | 813 | 0.55 |
| 1.0 | NB_1.64 | S2 (SW) | 519.9 | 496 | 6.8 | 813 | 0.55 |
| 1.0 | All other filters | S2 (SW) | 520.2 | 496 | 6.8 | 813 | 0.55 |
| 2.0 | All filters | S2 (SW) | 520.0 | 496 | 13.6 | 811 | 0.55 |
| 0.3 | NB_3.21 | L2 (LW) | 528.9 | 508 | 2 | 817 | 0.67 |
| 0.3 | NB_3.28 | L2 (LW) | 528.9 | 508 | 2 | 817 | 0.67 |
| 0.3 | NB_4.07 | L2 (LW) | 530.0 | 508 | 2 | 817 | 0.67 |
| 0.3 | L | L2 (LW) | 529.9 | 508 | 2 | 817 | 0.67 |
| 0.3 | NB_M | L2 (LW) | 526.7 | 508 | 2 | 817 | 0.67 |
| 0.3 | J+Block | L2 (LW) | 529.1 | 508 | 2 | 817 | 0.67 |
| 0.3 | H | L2 (LW) | 529.4 | 508 | 2 | 817 | 0.67 |
| 0.3 | Ks | L2 (LW) | 528.9 | 508 | 2 | 817 | 0.67 |
| 0.6 | NB_3.21 | L2 (LW) | 528.5 | 507 | 4 | 817 | 0.67 |
| 0.6 | NB_3.28 | L2 (LW) | 528.5 | 507 | 4 | 817 | 0.67 |
| 0.6 | NB_4.07 | L2 (LW) | 529.6 | 507 | 4 | 817 | 0.67 |
| 0.6 | L | L2 (LW) | 529.5 | 507 | 4 | 817 | 0.67 |
| 0.6 | NB_M | L2 (LW) | 526.3 | 507 | 4 | 817 | 0.67 |
| 0.6 | J+Block | L2 (LW) | 528.7 | 507 | 4 | 817 | 0.67 |
| 0.6 | H | L2 (LW) | 529.0 | 507 | 4 | 817 | 0.67 |
| 0.6 | Ks | L2 (LW) | 528.5 | 507 | 4 | 817 | 0.67 |
| 1.0 | NB_3.21 | L2 (LW) | 528.4 | 511 | 6.8 | 816 | 0.67 |
| 1.0 | NB_3.28 | L2 (LW) | 528.4 | 511 | 6.8 | 816 | 0.67 |
| 1.0 | NB_4.07 | L2 (LW) | 529.7 | 511 | 6.8 | 816 | 0.67 |
| 1.0 | L | L2 (LW) | 529.4 | 511 | 6.8 | 816 | 0.67 |
| 1.0 | NB_M | L2 (LW) | 526.2 | 511 | 6.8 | 816 | 0.67 |
| 1.0 | J+Block | L2 (LW) | 528.6 | 511 | 6.8 | 816 | 0.67 |
| 1.0 | H | L2 (LW) | 528.9 | 511 | 6.8 | 816 | 0.67 |
| 1.0 | Ks | L2 (LW) | 528.4 | 511 | 6.8 | 816 | 0.67 |
| 2.0 | NB_3.21 | L2 (LW) | 528.2 | 509 | 13.6 | 815 | 0.67 |
| 2.0 | NB_3.28 | L2 (LW) | 528.2 | 509 | 13.6 | 815 | 0.67 |
| 2.0 | NB_4.07 | L2 (LW) | 529.3 | 509 | 13.6 | 815 | 0.67 |
| 2.0 | L | L2 (LW) | 528.3 | 509 | 13.6 | 815 | 0.67 |
| 2.0 | NB_M | L2 (LW) | 526.0 | 509 | 13.6 | 815 | 0.67 |
| 2.0 | J+Block | L2 (LW) | 528.4 | 509 | 13.6 | 815 | 0.67 |
| 2.0 | H | L2 (LW) | 528.7 | 509 | 13.6 | 815 | 0.67 |
| 2.0 | Ks | L2 (LW) | 528.2 | 509 | 13.6 | 815 | 0.67 |
Observations taken between April 1st and August 20th 2001.
| Slit | Filter | Objective (Arm) | X center | Ycenter | Width | Length | Tilt |
| 0.3 | H | S2 (SW) | 510.2 | 493 | 2 | 812 | 0.55 |
| 0.3 | J | S2 (SW) | 510.3 | 493 | 2 | 812 | 0.55 |
| 0.3 | SZ | S2 (SW) | 510.9 | 493 | 2 | 812 | 0.55 |
| 0.3 | NB_1.06 | S2 (SW) | 510.2 | 493 | 2 | 812 | 0.55 |
| 0.3 | NB_2.29 | S2 (SW) | 510.3 | 493 | 2 | 812 | 0.55 |
| 0.3 | NB_1.64 | S2 (SW) | 510.2 | 493 | 2 | 812 | 0.55 |
| 0.3 | All other filters | S2 (SW) | 510.5 | 493 | 2 | 812 | 0.55 |
| 0.6 | H | S2 (SW) | 509.9 | 493 | 4 | 812 | 0.55 |
| 0.6 | J | S2 (SW) | 510.0 | 493 | 4 | 812 | 0.55 |
| 0.6 | SZ | S2 (SW) | 510.8 | 493 | 4 | 812 | 0.55 |
| 0.6 | NB_1.06 | S2 (SW) | 509.9 | 493 | 4 | 812 | 0.55 |
| 0.6 | NB_2.29 | S2 (SW) | 510.0 | 493 | 4 | 812 | 0.55 |
| 0.6 | NB_1.64 | S2 (SW) | 509.9 | 493 | 4 | 812 | 0.55 |
| 0.6 | All other filters | S2 (SW) | 510.2 | 493 | 4 | 812 | 0.55 |
| 1.0 | H | S2 (SW) | 510.4 | 494.5 | 6.8 | 812 | 0.55 |
| 1.0 | J | S2 (SW) | 510.5 | 494.5 | 6.8 | 812 | 0.55 |
| 1.0 | SZ | S2 (SW) | 511.1 | 494.5 | 6.8 | 812 | 0.55 |
| 1.0 | NB_1.06 | S2 (SW) | 510.4 | 494.5 | 6.8 | 812 | 0.55 |
| 1.0 | NB_2.29 | S2 (SW) | 510.5 | 494.5 | 6.8 | 812 | 0.55 |
| 1.0 | NB_1.64 | S2 (SW) | 510.4 | 494.5 | 6.8 | 812 | 0.55 |
| 1.0 | All other filters | S2 (SW) | 510.7 | 494.5 | 6.8 | 812 | 0.55 |
| 2.0 | All filters | S2 (SW) | 510.5 | 496 | 13.6 | 811 | 0.55 |