XSHOOTER trending system: HEALTH CHECK report
Last update: 2026-04-17T10:39:03 (UT)
[enable javascript for displaying time difference!]
General news:
NOTE: The Health Check and calChecker services have been moved to qcFlow. These pages are only maintained for comparison
and will be removed in 2026.
XSHOOTER news:
Report news:
Plot?
Symb?
Source *
Average ?
Thresholds ?
N_ data
QC1 parameter
Data downloads
Remarks
method
value
unit
method
value
1
QC1DB
MEDIAN
0.21
NONE
none
56
eff2
this |
last_yr |
all
Relative efficiency for VIS arm, range 7450A - 7560A
1
◊ QC1DB
none
NONE
none
0
eff2
this |
last_yr |
all
EFFMON template, data acquired under photometric conditions
2
QC1DB
MEDIAN
6.02e+04
ADU
none
56
counts2
this |
last_yr |
all
median star counts in VIS arm, range 7450A - 7560A
3
QC1DB
none
NONE
none
56
med_eff_0
this |
last_yr |
all
Chromatic efficiency plot for VIS arm ; the values trended in plot are marked. The plot is constituted from the following wavelength ranges: 9900A
3
QC1DB
none
NONE
none
56
med_eff_1
this |
last_yr |
all
9530A
3
QC1DB
none
NONE
none
56
med_eff_2
this |
last_yr |
all
8900A
3
QC1DB
none
NONE
none
56
med_eff_3
this |
last_yr |
all
8570A
3
QC1DB
none
NONE
none
0
med_eff_4
this |
last_yr |
all
8140A
3
QC1DB
none
NONE
none
56
med_eff_5
this |
last_yr |
all
7760A
3
QC1DB
none
NONE
none
56
med_eff_6
this |
last_yr |
all
7400A
3
QC1DB
none
NONE
none
56
med_eff_7
this |
last_yr |
all
7080A
3
QC1DB
none
NONE
none
56
med_eff_8
this |
last_yr |
all
67890
3
QC1DB
none
NONE
none
56
med_eff_9
this |
last_yr |
all
6520A
3
QC1DB
none
NONE
none
56
med_eff_10
this |
last_yr |
all
6270A
3
QC1DB
none
NONE
none
56
med_eff_11
this |
last_yr |
all
6030A
3
QC1DB
none
NONE
none
56
med_eff_12
this |
last_yr |
all
5820A
3
QC1DB
none
NONE
none
56
med_eff_13
this |
last_yr |
all
5620A
3
QC1DB
none
NONE
none
56
med_eff_14
this |
last_yr |
all
5340A
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1 scores: not implemented
data source: xshooter_fluxeff (QC1 database)
dataset: (numbers below apply to this dataset) eff2
median: 0.21 NONE
thresholds: none
N_data plotted: 56
[click plot for closeup]
Plot 2 scores: not implemented
data source: xshooter_fluxeff (QC1 database)
dataset: counts2
median: 6.02e+04 ADU
thresholds: none
N_data plotted: 56
[click plot for closeup]
Plot 3 scores: not implemented
data source: xshooter_fluxeff (QC1 database)
dataset: (numbers below apply to this dataset) med_eff_0
average: none
thresholds: none
N_data plotted: 56
[click plot for closeup]
This plot
This plot shows the efficiency per echelle order.
The efficiency is obtained from flux standard stars
acquired with a 5 arcsec wide slit.
The different count rates in Plot No. 2 originate from the
different magnitutes within the set of used flux standard stars.
General information
Click on any of the plots to see a close-up version .
The latest date is indicated on top of the plot.
If configured,
data points belonging to the latest date are specially marked
statistical averages are indicated by a solid line, and thresholds by broken lines
outliers are marked by a red asterisk. They are defined as data points outside the
threshold lines
"aliens" (= data points outside the plot Y limits) are marked by a red arrow (↑ or ↓ )
you can download the data for each parameter set if the 'Data downloads' link shows up