mirror sites: PL (internal link) HQ     [?]

Calibration completeness monitor

 

[all links are internal]             [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of "ago" time information]
CAL | HC | refs | QC
CALCHECKER
  HOME | HELP
  sl icon ALL INSTRUMENTS
ERIS
QC links:
CAL
ERIS calChecker: calibration completeness monitor (CAL4CAL)
Last update: 2025-09-05T00:46:17 (UT)
[?]
  Paranal date*: 2025-09-04         muc04 [?]   server: www.hq.eso.org PL
HELP ASSOC-RULES DETAILS
Last header: ERIS. 2025-09-04T20:15:24.109.hdr
transfer     ngas    [?]
  *Date on this monitor changes at 21:00 UT. Refresh frequency: 1/2hr day and night
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
Long-term calibrations and maintenance complete overview | how to execute     [?]
type of calibration validity (days) age (days) evaluation
IFS_EFFICIENCY_J_low30 27.0soft REMINDER: next 12 day(s)
NIX_EFFICIENCY_J_13mas30 30.1REMINDER: take as soon as possible
NIX_EFFICIENCY_H_13mas30 30.1REMINDER: take as soon as possible
NIX_EFFICIENCY_Ks_13mas30 30.1REMINDER: take as soon as possible
NIX_EFFICIENCY_J_27mas30 30.1REMINDER: take as soon as possible
NIX_EFFICIENCY_H_27mas30 30.1REMINDER: take as soon as possible
NIX_EFFICIENCY_Ks_27mas30 30.0REMINDER: take as soon as possible
NIX_EFFICIENCY_Short-Lp_13mas30 27.1soft REMINDER: next 11 day(s)
NIX_EFFICIENCY_Lp_13mas30 27.1soft REMINDER: next 11 day(s)
NIX_EFFICIENCY_Mp_13mas30 27.1soft REMINDER: next 11 day(s)
NIX_Astrometry_13mas-JHK90 90.0REMINDER: take as soon as possible
NIX_Astrometry_27mas-JHK90 90.0REMINDER: take as soon as possible
NIX_Astrometry_13mas-LM90 90.0REMINDER: take as soon as possible
ERIS news: The long term calibrations section is under development.

       

HELP | Q&A | ASSOC-RULES   history... | contact   monitors: DataTransferMonitor | BandWidth
  science  .   cal4cal  .    [?]     Product availability depends on the data transfer to Garching and the archive access there (check the "transfer" and "ngas" flags above).
  daytime calibs:   pending
DATE*:   [?]
[color if science data acquired]
2025-08-29
VM
24
report | NLT
2025-08-30

report | NLT
2025-08-31
VM
10
report | NLT
2025-09-01

report | NLT
2025-09-02

report | NLT
2025-09-03

report | NLT
2025-09-04

no data | NLT
LOST?
[not applicable
for 'cal4cal']
Calibration action?     [?]
[take these data types ...
Setup:
... for these setups]
r...
Raw CAL displays:     [?]
raw raw raw raw raw raw no CAL raw files      
P...
CAL product quality:     [?]
products products products products products products no CAL products      
Data types: Setup:        
FLAT 25mas_K_middle_10.0s_1  
 
ok
 
 
 
    all ok  
25mas_K_short_10.0s_1  
 
 
 
ok
 
    all ok  
100mas_K_middle_5.0s_1  
 
ok
 
 
 
    all ok  
100mas_K_short_5.0s_1  
 
 
 
ok
 
    all ok  
250mas_H_long_5.0s_1 ok
 
ok
 
 
 
    all ok  
250mas_H_short_5.0s_1 ok
 
ok
 
 
 
    all ok  
250mas_J_long_5.0s_1 ok
 
ok
 
 
 
    all ok  
250mas_J_short_5.0s_1 ok
 
ok
 
 
 
    all ok  
250mas_K_long_5.0s_1 ok
 
ok
 
 
 
    all ok  
250mas_K_low_5.0s_1 ok
 
ok
 
 
 
    all ok  
250mas_K_middle_5.0s_1  
 
ok
 
 
 
    all ok  
250mas_K_short_5.0s_1 ok
 
ok
 
ok
 
    all ok  
WAVE 25mas_K_middle  
 
ok
 
 
 
    all ok  
25mas_K_short  
 
 
 
ok
 
    all ok  
100mas_K_middle  
 
ok
 
 
 
    all ok  
100mas_K_short  
 
 
 
ok
 
    all ok  
250mas_H_long ok
 
ok
 
 
 
    all ok  
250mas_H_short ok
 
ok
 
 
 
    all ok  
250mas_J_long ok
 
ok
 
 
 
    all ok  
250mas_J_short ok
 
ok
 
 
 
    all ok  
250mas_K_long ok
 
ok
 
 
 
    all ok  
250mas_K_low ok
 
ok
 
 
 
    all ok  
250mas_K_middle  
 
ok
 
 
 
    all ok  
250mas_K_short ok
 
ok
 
ok
 
    all ok  
STD 250mas_H_long_4.0s_1 ok
 
 
 
 
 
    all ok  
250mas_H_long_5.0s_1  
 
ok
 
 
 
    all ok  
250mas_H_short_3.0s_1 ok
 
ok
 
 
 
    all ok  
250mas_J_long_3.0s_1 ok
 
ok
 
 
 
    all ok  
250mas_J_short_2.0s_1 ok
 
 
 
 
 
    all ok  
250mas_J_short_3.0s_1  
 
ok
 
 
 
    all ok  
250mas_K_long_7.0s_1 ok
 
 
 
 
 
    all ok  
250mas_K_long_8.0s_1  
 
ok
 
 
 
    all ok  
250mas_K_short_4.0s_1 ok
 
 
 
 
 
    all ok  
250mas_K_short_5.0s_1  
 
ok
 
 
 
    all ok  
NIX_FLAT 27mas-JHK_Br-g_SLOW_5.0s_1  
ok
 
 
 
 
    all ok  
27mas-JHK_Fe-II_SLOW_5.0s_1  
ok
 
 
 
 
    all ok  
27mas-JHK_H2-1-0S_SLOW_5.0s_1  
ok
 
 
 
 
    all ok  
27mas-JHK_H2-cont_SLOW_5.0s_1  
ok
 
 
 
 
    all ok  
27mas-JHK_H_SLOW_5.0s_1  
ok
 
 
 
 
    all ok  
27mas-JHK_IB-2.42_SLOW_5.0s_1  
ok
 
 
 
 
    all ok  
27mas-JHK_IB-2.48_SLOW_5.0s_1  
ok
 
 
 
 
    all ok  
27mas-JHK_J_SLOW_5.0s_1  
ok
 
 
 
 
    all ok  
27mas-JHK_K-peak_SLOW_5.0s_1  
ok
 
 
 
 
    all ok  
27mas-JHK_Ks_SLOW_5.0s_1  
ok
 
 
 
 
    all ok  
27mas-JHK_Pa-b_SLOW_5.0s_1  
ok
 
 
 
 
    all ok  
 
INFORMATION SPECIFIC TO ERIS           [?]
The following keys are used to define a ERIS/IFU science setup:

INS3.SPXW.NAME pixel scale
INS3.SPGW.NAME grating wheel
DET.SEQ1.DIT DIT
DET.NDIT NDIT

The following keys are used to define a ERIS/NIX science setup:

DET.READ.CURNAME
DET.SEQ1.DIT DIT
DET.NDIT NDIT
INS2.NXFW.NAME filter wheel
INS2.NXCW.NAME Camera wheel
Matching is done only on the Filter and Camera wheel values

for _LONG setup, we use :

INS2.NXFW.NAME: L-Broad, Mp, Short-Lp, Lp

for _LONG_Bra setup, we use :

INS2.NXFW.NAME: Br-a, Br-a-cont
For this _LONG_Bra, there is no SKY FLAT

for _SHORT setup, we use all the other filters:

CONFIGURATION           [?]
Number of days scanned: 7
Range of days for the issue memory (configured): 21
Range of days for the calibration memory (issue memory plus longest validity): 51
Days in the calibration&issue memory:
*Date on this monitor changes at: 21:00 UT
powered by QC [calChecker v4.6.8]   increm