mirror sites: PL (internal link) HQ     [?]

Calibration completeness monitor

 

[all links are internal]             [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of "ago" time information]
CAL | HC | refs | QC
CALCHECKER
  HOME | HELP
  sl icon ALL INSTRUMENTS
OMEGACAM
QC links:
CAL
OMEGACAM calChecker: calibration completeness monitor
Last update: 2026-05-07T09:11:45 (UT)
[?]
  Paranal date*: 2026-05-06         muc06 [?]   server: www.hq.eso.org PL
HELP ASSOC-RULES DETAILS
Last header: OMEGA. 2026-05-07T08:48:01.938.hdr
transfer     ngas    [?]
  *Date on this monitor changes at 21:00 UT. Refresh frequency: 1/2hr day and night
General news: NOTE: The Health Check and calChecker services have been moved to qcFlow. These pages are only maintained for comparison and will be removed in 2026.
Long-term calibrations and maintenance complete overview | how to execute     [?]
type of calibration validity (days) age (days) evaluation
STD_ZEROPOINT_ugriSDSS7 8.4REMINDER: take as soon as possible
OMEGACAM news:

       

HELP | Q&A | ASSOC-RULES   history... | contact   monitors: DataTransferMonitor | BandWidth
  science  .   cal4cal  .    [?]     Product availability depends on the data transfer to Garching and the archive access there (check the "transfer" and "ngas" flags above).
  daytime calibs:   pending
DATE*:   [?]
[color if science data acquired]
2026-04-30
VM
142
report | NLT
2026-05-01
VM
106
report | NLT
2026-05-02
VM
104
report | NLT
2026-05-03
VM
106
report | NLT
2026-05-04
VM
115
report | NLT
2026-05-05
VM
29
report | NLT
2026-05-06
102
no data | NLT
LOST?
[may require OB
grade review]
Calibration action?     [?]
[take these data types ...
Setup:
... for these setups]
r...
Raw CAL displays:     [?]
raw raw raw raw raw raw no CAL raw files      
P...
CAL product quality:     [?]
products products products products products products no CAL products      
Data types: Setup:        
SCIENCE NB_659 ok
ok
ok
ok
ok
 
nok
[daycals not yet started]
  STD NB_659
g_SDSS ok
ok
LOST
[not yet analyzed]
ok
ok
 
nok
[daycals not yet started]
STD STD g_SDSS
i_SDSS ok
ok
LOST
[not yet analyzed]
ok
ok
LOST
[not yet analyzed]
nok
[daycals not yet started]
STD STD i_SDSS
r_SDSS ok
ok
LOST
[not yet analyzed]
ok
ok
LOST
[not yet analyzed]
nok
[daycals not yet started]
STD STD r_SDSS
u_SDSS ok
ok
LOST
[not yet analyzed]
ok
ok
 
nok
[daycals not yet started]
STD STD u_SDSS
z_SDSS ok
ok
LOST
[not yet analyzed]
ok
ok
 
nok
[daycals not yet started]
STD STD z_SDSS
 
INFORMATION SPECIFIC TO OMEGACAM           [?]
The following keys are used to define a SCIENCE OmegaCAM setup:

INS.FILT1.NAME
availabe filters:    u_SDSS / g_SDSS / r_SDSS / i_SDSS / z_SDSS / u_g_r_i_SDSS
                               B_JOHN / V_JOHN / v_STRM / H_ALPHA / opaque
                               NB_454_494_533_575 / NB_617_710_755_817 / NB_852_861_869_878

CONFIGURATION           [?]
Number of days scanned: 7
Range of days for the issue memory (configured): 20
Range of days for the calibration memory (issue memory plus longest validity): 27
Days in the calibration&issue memory:
*Date on this monitor changes at: 21:00 UT
powered by QC [calChecker v4.6.8]   increm