#Relative Filter Curve created with the VISIR imaging detector and the VISIR calibration unit. #Author = Maximilian Haeberle Contact: max.haeberle18@gmail.com # #Filter = PAH2_2 #Central_Wavelength = 11.6844 #FWHM =0.372 # #Minimum_Wavelength = 10.9668 #Maximum_Wavelength = 12.4668 #Wavelength Step = 0.0120001 # #Exposure information #DIT = 0.017002 #NDIT = 50 #NABBA = 2 # #Data Analysis Information #Zeroth Order = 192 #Normalization factor=22918.7 #Aperture r0= 9.0 #Annulus rA1= 28.53 #Annulus rA2= 33.93 #Mean of first background file = 19161.8027344 # #encvalue wavelength transmission transmission_error 9331.0 10.9668 -0.00352946 0.00835972 9341.0 10.9788 -0.00489464 0.00835972 9351.0 10.9908 0.00312696 0.00835972 9361.0 11.0028 0.00227828 0.00835972 9371.0 11.0148 0.00263817 0.00835972 9381.0 11.0268 0.0165118 0.00835972 9391.0 11.0388 0.00409535 0.00835972 9401.0 11.0508 -0.00225774 0.00835972 9411.0 11.0628 -0.000849715 0.00835972 9421.0 11.0748 0.00416893 0.00835972 9431.0 11.0868 0.0118504 0.00835972 9441.0 11.0988 0.00227612 0.00835972 9451.0 11.1108 -0.000894202 0.00835972 9461.0 11.1228 0.00766345 0.00835972 9471.0 11.1348 -0.00766511 0.00835972 9481.0 11.1468 0.00802281 0.00835972 9491.0 11.1588 -0.0163972 0.00835972 9501.0 11.1708 0.00266002 0.00835972 9511.0 11.1828 -0.00104171 0.00835972 9521.0 11.1948 -0.000542404 0.00835972 9531.0 11.2068 -0.00469972 0.00835972 9541.0 11.2188 0.0115514 0.00835972 9551.0 11.2308 0.0194878 0.00835972 9561.0 11.2428 0.00589444 0.00835972 9571.0 11.2548 0.0120765 0.00835972 9581.0 11.2668 0.00583751 0.00835972 9591.0 11.2788 0.0092278 0.00835972 9601.0 11.2908 0.00335777 0.00835972 9611.0 11.3028 0.0111679 0.00835972 9621.0 11.3148 0.0212876 0.00835972 9631.0 11.3268 0.0276203 0.00835972 9641.0 11.3388 0.0154404 0.00835972 9651.0 11.3508 0.017717 0.00835972 9661.0 11.3628 0.0114491 0.00835972 9671.0 11.3748 0.0238695 0.00835972 9681.0 11.3868 0.0332373 0.00835972 9691.0 11.3988 0.0579097 0.00835972 9701.0 11.4108 0.0797507 0.00835972 9711.0 11.4228 0.0853218 0.00835972 9721.0 11.4348 0.103174 0.00835972 9731.0 11.4468 0.138261 0.00835972 9741.0 11.4588 0.194974 0.00835972 9751.0 11.4708 0.243576 0.00835972 9761.0 11.4828 0.3204 0.00835972 9771.0 11.4948 0.414486 0.00835972 9781.0 11.5068 0.530493 0.00835972 9791.0 11.5188 0.656659 0.00835972 9801.0 11.5308 0.77512 0.00835972 9811.0 11.5428 0.841808 0.00835972 9821.0 11.5548 0.91642 0.00835972 9831.0 11.5668 0.967659 0.00835972 9841.0 11.5788 0.996333 0.00835972 9851.0 11.5908 0.993494 0.00835972 9861.0 11.6028 0.981186 0.00835972 9871.0 11.6148 1.0 0.00835972 9881.0 11.6268 0.964001 0.00835972 9891.0 11.6388 0.990504 0.00835972 9901.0 11.6508 0.983455 0.00835972 9911.0 11.6628 0.98089 0.00835972 9921.0 11.6748 0.983399 0.00835972 9931.0 11.6868 0.979494 0.00835972 9941.0 11.6988 0.988109 0.00835972 9951.0 11.7108 0.955403 0.00835972 9961.0 11.7228 0.945277 0.00835972 9971.0 11.7348 0.940415 0.00835972 9981.0 11.7468 0.902269 0.00835972 9991.0 11.7588 0.899486 0.00835972 10001.0 11.7708 0.885501 0.00835972 10011.0 11.7828 0.881263 0.00835972 10021.0 11.7948 0.882943 0.00835972 10031.0 11.8068 0.867688 0.00835972 10041.0 11.8188 0.84708 0.00835972 10051.0 11.8308 0.800038 0.00835972 10061.0 11.8428 0.769011 0.00835972 10071.0 11.8548 0.680371 0.00835972 10081.0 11.8668 0.568052 0.00835972 10091.0 11.8788 0.464446 0.00835972 10101.0 11.8908 0.377574 0.00835972 10111.0 11.9028 0.277673 0.00835972 10121.0 11.9148 0.203246 0.00835972 10131.0 11.9268 0.138673 0.00835972 10141.0 11.9388 0.0967568 0.00835972 10151.0 11.9508 0.0852834 0.00835972 10161.0 11.9628 0.0556051 0.00835972 10171.0 11.9748 0.0418684 0.00835972 10181.0 11.9868 0.0216437 0.00835972 10191.0 11.9988 0.000434203 0.00835972 10201.0 12.0108 0.0242014 0.00835972 10211.0 12.0228 0.0160665 0.00835972 10221.0 12.0348 -0.00357217 0.00835972 10231.0 12.0468 0.000345616 0.00835972 10241.0 12.0588 0.00127531 0.00835972 10251.0 12.0708 -0.00254051 0.00835972 10261.0 12.0828 -0.0033349 0.00835972 10271.0 12.0948 -0.000563584 0.00835972 10281.0 12.1068 -0.00106886 0.00835972 10291.0 12.1188 0.0144929 0.00835972 10301.0 12.1308 0.00462524 0.00835972 10311.0 12.1428 -0.000987971 0.00835972 10321.0 12.1548 -0.00536014 0.00835972 10331.0 12.1668 0.0154983 0.00835972 10341.0 12.1788 0.00281509 0.00835972 10351.0 12.1908 -0.00406452 0.00835972 10361.0 12.2028 0.00363708 0.00835972 10371.0 12.2148 -0.0108462 0.00835972 10381.0 12.2268 0.00685252 0.00835972 10391.0 12.2388 0.0134152 0.00835972 10401.0 12.2508 -0.00877886 0.00835972 10411.0 12.2628 -0.00509179 0.00835972 10421.0 12.2748 0.00704046 0.00835972 10431.0 12.2868 0.0149444 0.00835972 10441.0 12.2988 0.0179866 0.00835972 10451.0 12.3108 0.00898709 0.00835972 10461.0 12.3228 0.00472531 0.00835972 10471.0 12.3348 -0.00623908 0.00835972 10481.0 12.3468 0.000748324 0.00835972 10491.0 12.3588 -0.000536319 0.00835972 10501.0 12.3708 -0.00437985 0.00835972 10511.0 12.3828 0.0123631 0.00835972 10521.0 12.3948 -0.000137563 0.00835972 10531.0 12.4068 0.0174879 0.00835972 10541.0 12.4188 -0.0026773 0.00835972 10551.0 12.4308 -0.0106687 0.00835972 10561.0 12.4428 -0.00423396 0.00835972 10571.0 12.4548 0.00944685 0.00835972 10581.0 12.4668 0.00486395 0.00835972