#Relative Filter Curve created with the VISIR imaging detector and the VISIR calibration unit. #Author = Maximilian Haeberle Contact: max.haeberle18@gmail.com # #Filter = J122 #Central_Wavelength = 11.9261 #FWHM =0.516 # #Minimum_Wavelength = 10.9668 #Maximum_Wavelength = 12.9588 #Wavelength Step = 0.0120001 # #Exposure information #DIT = 0.0105569 #NDIT = 50 #NABBA = 2 # #Data Analysis Information #Zeroth Order = 192 #Normalization factor=14092.3 #Aperture r0= 9.0 #Annulus rA1= 28.53 #Annulus rA2= 33.93 #Mean of first background file = 19088.1894531 # #encvalue wavelength transmission transmission_error 9331.0 10.9668 0.00711421 0.0125732 9341.0 10.9788 -0.00812761 0.0125732 9351.0 10.9908 0.00133718 0.0125732 9361.0 11.0028 0.00464502 0.0125732 9371.0 11.0148 0.0233691 0.0125732 9381.0 11.0268 -0.0172862 0.0125732 9391.0 11.0388 -0.00371832 0.0125732 9401.0 11.0508 -0.0264508 0.0125732 9411.0 11.0628 0.00107383 0.0125732 9421.0 11.0748 -0.00254656 0.0125732 9431.0 11.0868 0.0150211 0.0125732 9441.0 11.0988 0.025756 0.0125732 9451.0 11.1108 0.00120722 0.0125732 9461.0 11.1228 0.00736666 0.0125732 9471.0 11.1348 -0.00550146 0.0125732 9481.0 11.1468 0.00615837 0.0125732 9491.0 11.1588 0.0227964 0.0125732 9501.0 11.1708 0.0130523 0.0125732 9511.0 11.1828 0.0169719 0.0125732 9521.0 11.1948 -0.00406435 0.0125732 9531.0 11.2068 0.00231247 0.0125732 9541.0 11.2188 0.00553148 0.0125732 9551.0 11.2308 0.00708867 0.0125732 9561.0 11.2428 -0.0124304 0.0125732 9571.0 11.2548 0.00127031 0.0125732 9581.0 11.2668 0.0157697 0.0125732 9591.0 11.2788 0.00296489 0.0125732 9601.0 11.2908 0.0125779 0.0125732 9611.0 11.3028 0.0102865 0.0125732 9621.0 11.3148 0.0236239 0.0125732 9631.0 11.3268 0.0295908 0.0125732 9641.0 11.3388 0.0053241 0.0125732 9651.0 11.3508 0.0189754 0.0125732 9661.0 11.3628 -0.00294828 0.0125732 9671.0 11.3748 0.01234 0.0125732 9681.0 11.3868 0.0174841 0.0125732 9691.0 11.3988 0.00515527 0.0125732 9701.0 11.4108 0.0144406 0.0125732 9711.0 11.4228 0.0112094 0.0125732 9721.0 11.4348 -0.0138482 0.0125732 9731.0 11.4468 0.029569 0.0125732 9741.0 11.4588 0.0417923 0.0125732 9751.0 11.4708 -0.00563264 0.0125732 9761.0 11.4828 0.0209754 0.0125732 9771.0 11.4948 0.0677119 0.0125732 9781.0 11.5068 0.0341655 0.0125732 9791.0 11.5188 0.0636367 0.0125732 9801.0 11.5308 0.0519195 0.0125732 9811.0 11.5428 0.0869782 0.0125732 9821.0 11.5548 0.107722 0.0125732 9831.0 11.5668 0.120247 0.0125732 9841.0 11.5788 0.127903 0.0125732 9851.0 11.5908 0.142716 0.0125732 9861.0 11.6028 0.178102 0.0125732 9871.0 11.6148 0.225129 0.0125732 9881.0 11.6268 0.25864 0.0125732 9891.0 11.6388 0.317747 0.0125732 9901.0 11.6508 0.377626 0.0125732 9911.0 11.6628 0.424813 0.0125732 9921.0 11.6748 0.495832 0.0125732 9931.0 11.6868 0.555031 0.0125732 9941.0 11.6988 0.631894 0.0125732 9951.0 11.7108 0.68369 0.0125732 9961.0 11.7228 0.767559 0.0125732 9971.0 11.7348 0.810801 0.0125732 9981.0 11.7468 0.857584 0.0125732 9991.0 11.7588 0.925862 0.0125732 10001.0 11.7708 0.956065 0.0125732 10011.0 11.7828 0.975115 0.0125732 10021.0 11.7948 0.999165 0.0125732 10031.0 11.8068 0.996351 0.0125732 10041.0 11.8188 0.998515 0.0125732 10051.0 11.8308 0.982745 0.0125732 10061.0 11.8428 1.0 0.0125732 10071.0 11.8548 0.996319 0.0125732 10081.0 11.8668 0.932688 0.0125732 10091.0 11.8788 0.969644 0.0125732 10101.0 11.8908 0.935929 0.0125732 10111.0 11.9028 0.904753 0.0125732 10121.0 11.9148 0.908937 0.0125732 10131.0 11.9268 0.941136 0.0125732 10141.0 11.9388 0.923455 0.0125732 10151.0 11.9508 0.875452 0.0125732 10161.0 11.9628 0.880741 0.0125732 10171.0 11.9748 0.90189 0.0125732 10181.0 11.9868 0.865916 0.0125732 10191.0 11.9988 0.826427 0.0125732 10201.0 12.0108 0.839769 0.0125732 10211.0 12.0228 0.810604 0.0125732 10221.0 12.0348 0.785744 0.0125732 10231.0 12.0468 0.797067 0.0125732 10241.0 12.0588 0.820498 0.0125732 10251.0 12.0708 0.799639 0.0125732 10261.0 12.0828 0.745438 0.0125732 10271.0 12.0948 0.764118 0.0125732 10281.0 12.1068 0.766873 0.0125732 10291.0 12.1188 0.747123 0.0125732 10301.0 12.1308 0.705752 0.0125732 10311.0 12.1428 0.724272 0.0125732 10321.0 12.1548 0.663649 0.0125732 10331.0 12.1668 0.610176 0.0125732 10341.0 12.1788 0.567094 0.0125732 10351.0 12.1908 0.531465 0.0125732 10361.0 12.2028 0.463914 0.0125732 10371.0 12.2148 0.402404 0.0125732 10381.0 12.2268 0.344858 0.0125732 10391.0 12.2388 0.305702 0.0125732 10401.0 12.2508 0.252861 0.0125732 10411.0 12.2628 0.207481 0.0125732 10421.0 12.2748 0.165779 0.0125732 10431.0 12.2868 0.145675 0.0125732 10441.0 12.2988 0.137198 0.0125732 10451.0 12.3108 0.106416 0.0125732 10461.0 12.3228 0.0860497 0.0125732 10471.0 12.3348 0.077127 0.0125732 10481.0 12.3468 0.0795356 0.0125732 10491.0 12.3588 0.0280227 0.0125732 10501.0 12.3708 0.0611652 0.0125732 10511.0 12.3828 0.0338115 0.0125732 10521.0 12.3948 0.0355284 0.0125732 10531.0 12.4068 0.00562232 0.0125732 10541.0 12.4188 0.0226555 0.0125732 10551.0 12.4308 0.000941453 0.0125732 10561.0 12.4428 0.0107546 0.0125732 10571.0 12.4548 0.0257303 0.0125732 10581.0 12.4668 0.0234326 0.0125732 10591.0 12.4788 -0.00262821 0.0125732 10601.0 12.4908 -0.00744826 0.0125732 10611.0 12.5028 0.00795315 0.0125732 10621.0 12.5148 0.000762493 0.0125732 10631.0 12.5268 -0.00569197 0.0125732 10641.0 12.5388 0.0322405 0.0125732 10651.0 12.5508 0.0223096 0.0125732 10661.0 12.5628 0.007384 0.0125732 10671.0 12.5748 -0.0220415 0.0125732 10681.0 12.5868 0.00970245 0.0125732 10691.0 12.5988 0.00316293 0.0125732 10701.0 12.6108 0.00517777 0.0125732 10711.0 12.6228 0.00124362 0.0125732 10721.0 12.6348 0.0165077 0.0125732 10731.0 12.6468 -0.00556487 0.0125732 10741.0 12.6588 -0.00105001 0.0125732 10751.0 12.6708 0.00626155 0.0125732 10761.0 12.6828 -5.80648e-05 0.0125732 10771.0 12.6948 0.00838049 0.0125732 10781.0 12.7068 -0.00591663 0.0125732 10791.0 12.7188 -0.00714783 0.0125732 10801.0 12.7308 0.00609173 0.0125732 10811.0 12.7428 0.00249077 0.0125732 10821.0 12.7548 -0.0081091 0.0125732 10831.0 12.7668 -0.00126138 0.0125732 10841.0 12.7788 -0.00278496 0.0125732 10851.0 12.7908 0.0297984 0.0125732 10861.0 12.8028 -0.0174964 0.0125732 10871.0 12.8148 -0.0110379 0.0125732 10881.0 12.8268 -0.00947665 0.0125732 10891.0 12.8388 0.0087386 0.0125732 10901.0 12.8508 0.0148767 0.0125732 10911.0 12.8628 -0.012542 0.0125732 10921.0 12.8748 -0.0117159 0.0125732 10931.0 12.8868 0.00654614 0.0125732 10941.0 12.8988 -0.00347002 0.0125732 10951.0 12.9108 0.0275159 0.0125732 10961.0 12.9228 -0.00701975 0.0125732 10971.0 12.9348 0.00650934 0.0125732 10981.0 12.9468 -0.00695452 0.0125732 10991.0 12.9588 -0.0175021 0.0125732