#Relative Filter Curve created with the VISIR imaging detector and the VISIR calibration unit. #Author = Maximilian Haeberle Contact: max.haeberle18@gmail.com # #Filter = B117 #Central_Wavelength = 11.5143 #FWHM =0.9 # #Minimum_Wavelength = 9.966 #Maximum_Wavelength = 12.966 #Wavelength Step = 0.0120001 # #Exposure information #DIT = 0.0054173 #NDIT = 50 #NABBA = 2 # #Data Analysis Information #Zeroth Order = 192 #Normalization factor=14962.1 #Aperture r0= 9.0 #Annulus rA1= 28.53 #Annulus rA2= 33.93 #Mean of first background file = 19305.203125 # #encvalue wavelength transmission transmission_error 8497.0 9.966 0.014996 0.0137876 8507.0 9.978 0.00378361 0.0137876 8517.0 9.99 0.0159413 0.0137876 8527.0 10.002 -0.00959004 0.0137876 8537.0 10.014 0.00231022 0.0137876 8547.0 10.026 0.0148076 0.0137876 8557.0 10.038 0.018592 0.0137876 8567.0 10.05 -0.0249705 0.0137876 8577.0 10.062 -0.019289 0.0137876 8587.0 10.074 0.00705817 0.0137876 8597.0 10.086 0.00493147 0.0137876 8607.0 10.098 0.00707837 0.0137876 8617.0 10.11 -0.0159915 0.0137876 8627.0 10.122 -0.0131733 0.0137876 8637.0 10.134 -0.00285364 0.0137876 8647.0 10.146 -0.0070413 0.0137876 8657.0 10.158 0.0285818 0.0137876 8667.0 10.17 0.00697211 0.0137876 8677.0 10.182 0.00649968 0.0137876 8687.0 10.194 -0.00759289 0.0137876 8697.0 10.206 0.00492954 0.0137876 8707.0 10.218 0.029877 0.0137876 8717.0 10.23 -0.000641809 0.0137876 8727.0 10.242 -0.0108518 0.0137876 8737.0 10.254 0.0131 0.0137876 8747.0 10.266 0.015033 0.0137876 8757.0 10.278 0.00905461 0.0137876 8767.0 10.29 0.00292384 0.0137876 8777.0 10.302 0.00355747 0.0137876 8787.0 10.314 -0.00055482 0.0137876 8797.0 10.326 0.0151651 0.0137876 8807.0 10.338 -0.00308905 0.0137876 8817.0 10.35 -0.00144171 0.0137876 8827.0 10.362 -0.0140078 0.0137876 8837.0 10.374 0.00300949 0.0137876 8847.0 10.386 0.00981792 0.0137876 8857.0 10.398 0.0183211 0.0137876 8867.0 10.41 0.011841 0.0137876 8877.0 10.422 0.00856734 0.0137876 8887.0 10.434 0.0159404 0.0137876 8897.0 10.446 0.00357268 0.0137876 8907.0 10.458 0.00643036 0.0137876 8917.0 10.47 0.0129092 0.0137876 8927.0 10.482 0.0343746 0.0137876 8937.0 10.494 0.035179 0.0137876 8947.0 10.506 0.0194254 0.0137876 8957.0 10.518 0.0294277 0.0137876 8967.0 10.53 0.0184296 0.0137876 8977.0 10.542 -0.00476871 0.0137876 8987.0 10.554 0.0253896 0.0137876 8997.0 10.566 0.0117598 0.0137876 9007.0 10.578 0.0253225 0.0137876 9017.0 10.59 0.0302733 0.0137876 9027.0 10.602 0.0573439 0.0137876 9037.0 10.614 0.0354271 0.0137876 9047.0 10.626 0.0287785 0.0137876 9057.0 10.638 0.00947116 0.0137876 9067.0 10.65 0.0216206 0.0137876 9077.0 10.662 0.0550335 0.0137876 9087.0 10.674 0.0467645 0.0137876 9097.0 10.686 0.0674411 0.0137876 9107.0 10.698 0.0658235 0.0137876 9117.0 10.71 0.0401089 0.0137876 9127.0 10.722 0.0458437 0.0137876 9137.0 10.734 0.0738178 0.0137876 9147.0 10.746 0.0687943 0.0137876 9157.0 10.758 0.0566787 0.0137876 9167.0 10.77 0.0636738 0.0137876 9177.0 10.782 0.0603727 0.0137876 9187.0 10.794 0.0660111 0.0137876 9197.0 10.806 0.074345 0.0137876 9207.0 10.818 0.0698949 0.0137876 9217.0 10.83 0.0809686 0.0137876 9227.0 10.842 0.0875027 0.0137876 9237.0 10.854 0.0809971 0.0137876 9247.0 10.866 0.077179 0.0137876 9257.0 10.878 0.0982512 0.0137876 9267.0 10.89 0.104455 0.0137876 9277.0 10.902 0.102032 0.0137876 9287.0 10.914 0.100262 0.0137876 9297.0 10.926 0.127577 0.0137876 9307.0 10.938 0.12324 0.0137876 9317.0 10.95 0.154163 0.0137876 9327.0 10.962 0.172542 0.0137876 9337.0 10.974 0.161083 0.0137876 9347.0 10.986 0.211556 0.0137876 9357.0 10.998 0.231544 0.0137876 9367.0 11.01 0.242501 0.0137876 9377.0 11.022 0.287637 0.0137876 9387.0 11.034 0.322238 0.0137876 9397.0 11.046 0.32807 0.0137876 9407.0 11.058 0.377382 0.0137876 9417.0 11.07 0.42914 0.0137876 9427.0 11.082 0.498914 0.0137876 9437.0 11.094 0.55653 0.0137876 9447.0 11.106 0.586049 0.0137876 9457.0 11.118 0.651626 0.0137876 9467.0 11.13 0.714539 0.0137876 9477.0 11.142 0.755982 0.0137876 9487.0 11.154 0.806625 0.0137876 9497.0 11.166 0.866838 0.0137876 9507.0 11.178 0.895421 0.0137876 9517.0 11.19 0.92812 0.0137876 9527.0 11.202 0.9443 0.0137876 9537.0 11.214 0.987181 0.0137876 9547.0 11.226 0.990196 0.0137876 9557.0 11.238 0.973791 0.0137876 9567.0 11.25 0.989402 0.0137876 9577.0 11.262 0.986527 0.0137876 9587.0 11.274 1.0 0.0137876 9597.0 11.286 0.979076 0.0137876 9607.0 11.298 0.957353 0.0137876 9617.0 11.31 0.946003 0.0137876 9627.0 11.322 0.933763 0.0137876 9637.0 11.334 0.925101 0.0137876 9647.0 11.346 0.917628 0.0137876 9657.0 11.358 0.903618 0.0137876 9667.0 11.37 0.899557 0.0137876 9677.0 11.382 0.878556 0.0137876 9687.0 11.394 0.869346 0.0137876 9697.0 11.406 0.88404 0.0137876 9707.0 11.418 0.869013 0.0137876 9717.0 11.43 0.858422 0.0137876 9727.0 11.442 0.859316 0.0137876 9737.0 11.454 0.84382 0.0137876 9747.0 11.466 0.836327 0.0137876 9757.0 11.478 0.82618 0.0137876 9767.0 11.49 0.82481 0.0137876 9777.0 11.502 0.795792 0.0137876 9787.0 11.514 0.81938 0.0137876 9797.0 11.526 0.82436 0.0137876 9807.0 11.538 0.81043 0.0137876 9817.0 11.55 0.801543 0.0137876 9827.0 11.562 0.797848 0.0137876 9837.0 11.574 0.814394 0.0137876 9847.0 11.586 0.774595 0.0137876 9857.0 11.598 0.796079 0.0137876 9867.0 11.61 0.801339 0.0137876 9877.0 11.622 0.784595 0.0137876 9887.0 11.634 0.813591 0.0137876 9897.0 11.646 0.785429 0.0137876 9907.0 11.658 0.779171 0.0137876 9917.0 11.67 0.75242 0.0137876 9927.0 11.682 0.783235 0.0137876 9937.0 11.694 0.783431 0.0137876 9947.0 11.706 0.752369 0.0137876 9957.0 11.718 0.754925 0.0137876 9967.0 11.73 0.741224 0.0137876 9977.0 11.742 0.748981 0.0137876 9987.0 11.754 0.728902 0.0137876 9997.0 11.766 0.733566 0.0137876 10007.0 11.778 0.723098 0.0137876 10017.0 11.79 0.710576 0.0137876 10027.0 11.802 0.707806 0.0137876 10037.0 11.814 0.711965 0.0137876 10047.0 11.826 0.6907 0.0137876 10057.0 11.838 0.68029 0.0137876 10067.0 11.85 0.681368 0.0137876 10077.0 11.862 0.666273 0.0137876 10087.0 11.874 0.659735 0.0137876 10097.0 11.886 0.6566 0.0137876 10107.0 11.898 0.629808 0.0137876 10117.0 11.91 0.612579 0.0137876 10127.0 11.922 0.611485 0.0137876 10137.0 11.934 0.586611 0.0137876 10147.0 11.946 0.564493 0.0137876 10157.0 11.958 0.548052 0.0137876 10167.0 11.97 0.563427 0.0137876 10177.0 11.982 0.528972 0.0137876 10187.0 11.994 0.476762 0.0137876 10197.0 12.006 0.470177 0.0137876 10207.0 12.018 0.467626 0.0137876 10217.0 12.03 0.408134 0.0137876 10227.0 12.042 0.371744 0.0137876 10237.0 12.054 0.354309 0.0137876 10247.0 12.066 0.357058 0.0137876 10257.0 12.078 0.292427 0.0137876 10267.0 12.09 0.250254 0.0137876 10277.0 12.102 0.226265 0.0137876 10287.0 12.114 0.236652 0.0137876 10297.0 12.126 0.228097 0.0137876 10307.0 12.138 0.18589 0.0137876 10317.0 12.15 0.178977 0.0137876 10327.0 12.162 0.147207 0.0137876 10337.0 12.174 0.145515 0.0137876 10347.0 12.186 0.120171 0.0137876 10357.0 12.198 0.123841 0.0137876 10367.0 12.21 0.107936 0.0137876 10377.0 12.222 0.0795669 0.0137876 10387.0 12.234 0.0706155 0.0137876 10397.0 12.246 0.0770368 0.0137876 10407.0 12.258 0.0642382 0.0137876 10417.0 12.27 0.0526365 0.0137876 10427.0 12.282 0.0472053 0.0137876 10437.0 12.294 0.048608 0.0137876 10447.0 12.306 0.0526209 0.0137876 10457.0 12.318 0.0195493 0.0137876 10467.0 12.33 0.0271525 0.0137876 10477.0 12.342 0.0113855 0.0137876 10487.0 12.354 0.0205301 0.0137876 10497.0 12.366 0.0309144 0.0137876 10507.0 12.378 0.045567 0.0137876 10517.0 12.39 0.014815 0.0137876 10527.0 12.402 0.0236382 0.0137876 10537.0 12.414 0.00733467 0.0137876 10547.0 12.426 0.0450808 0.0137876 10557.0 12.438 0.00679261 0.0137876 10567.0 12.45 0.00265763 0.0137876 10577.0 12.462 0.039245 0.0137876 10587.0 12.474 -0.00405536 0.0137876 10597.0 12.486 0.00729581 0.0137876 10607.0 12.498 0.00258716 0.0137876 10617.0 12.51 0.00362765 0.0137876 10627.0 12.522 0.010728 0.0137876 10637.0 12.534 0.0142093 0.0137876 10647.0 12.546 0.0204736 0.0137876 10657.0 12.558 0.00784941 0.0137876 10667.0 12.57 0.0020522 0.0137876 10677.0 12.582 -0.0071559 0.0137876 10687.0 12.594 0.034907 0.0137876 10697.0 12.606 0.000817769 0.0137876 10707.0 12.618 -0.000382186 0.0137876 10717.0 12.63 0.0236544 0.0137876 10727.0 12.642 0.0115913 0.0137876 10737.0 12.654 0.00143999 0.0137876 10747.0 12.666 0.00864771 0.0137876 10757.0 12.678 -0.00570909 0.0137876 10767.0 12.69 0.0148426 0.0137876 10777.0 12.702 0.0201898 0.0137876 10787.0 12.714 -0.00618745 0.0137876 10797.0 12.726 0.00936121 0.0137876 10807.0 12.738 -0.0150971 0.0137876 10817.0 12.75 -0.00502522 0.0137876 10827.0 12.762 0.00515437 0.0137876 10837.0 12.774 0.0156122 0.0137876 10847.0 12.786 0.0299108 0.0137876 10857.0 12.798 -0.0115497 0.0137876 10867.0 12.81 -0.00858744 0.0137876 10877.0 12.822 0.023599 0.0137876 10887.0 12.834 0.0078743 0.0137876 10897.0 12.846 0.00375421 0.0137876 10907.0 12.858 0.00839117 0.0137876 10917.0 12.87 0.0138127 0.0137876 10927.0 12.882 0.00945685 0.0137876 10937.0 12.894 0.00468288 0.0137876 10947.0 12.906 -0.000651156 0.0137876 10957.0 12.918 -0.0167189 0.0137876 10967.0 12.93 -0.00923113 0.0137876 10977.0 12.942 -0.0114773 0.0137876 10987.0 12.954 -0.0204876 0.0137876 10997.0 12.966 -0.0102158 0.0137876