# wave V1simple V2simple V3simple V4simple # 3300 0.0513595 0.169149 0.0861379 0.193311 3305.27 0.0494858 0.0926245 0.161303 0.0145748 3310.54 0.134724 0.106237 0.112033 0.116737 3315.82 0.0475898 0.234616 0.0309223 0.0485815 3321.09 0.085306 0.218827 0.037653 0.154309 3326.36 0.178429 -0.00941301 0.00913964 0.0406543 3331.63 0.0986362 -0.0779162 0.0566523 0.0135827 3336.9 -0.0111302 0.0386868 0.0839302 0.113145 3342.18 -0.0158265 0.158561 0.123949 0.243869 3347.45 0.0973907 0.140628 0.108467 0.168401 3352.72 0.0948526 0.0819233 0.0842403 0.142129 3357.99 -0.011442 -0.0297601 0.0216953 -0.0340162 3363.26 0.129712 0.333222 0.121162 0.0342036 3368.54 0.0676428 0.116131 0.107197 0.0620337 3373.81 -0.0156895 0.209305 0.117018 0.116216 3379.08 0.0111461 0.0380702 0.0829686 0.21247 3384.35 0.0158003 -0.0747675 0.125975 0.135275 3389.62 0.122301 -0.0120646 0.0257742 0.0930427 3394.9 0.0843255 0.15678 -0.0475805 0.135844 3400.17 0.0754015 -0.0147086 0.134564 0.0324347 3405.44 0.0866372 -0.0363893 0.114396 0.179659 3410.71 0.0964896 0.00553833 0.054685 0.0708973 3415.98 0.0364349 0.0300771 0.0124658 -0.103927 3421.26 0.0752925 0.113422 0.101375 -0.0554168 3426.53 0.0685443 -0.0270875 0.224545 0.0960908 3431.8 0.00483933 0.0739961 0.203991 0.0484295 3437.07 0.016591 0.131021 0.0968839 0.0061655 3442.34 0.134292 0.152105 0.0386556 0.104162 3447.62 0.126328 0.0606478 0.0629399 0.104066 3452.89 0.133208 0.077604 0.106112 0.168578 3458.16 0.117758 0.198034 0.169377 0.131124 3463.43 0.0773832 0.0368646 0.0699162 0.154516 3468.71 -0.0477554 0.159842 0.0703049 0.14347 3473.98 0.110057 0.0592302 0.0356586 0.112317 3479.25 0.0823559 -0.019136 0.0703719 0.101178 3484.52 0.0607663 0.107687 0.129227 0.145464 3489.79 0.0277431 0.0442914 0.0335846 0.134489 3495.07 0.0323778 0.0291846 0.0504257 0.167122 3500.34 0.0840747 0.0440675 -0.0164125 0.120769 3505.61 0.11837 0.104995 0.0340595 0.0358539 3510.88 0.0324431 0.136759 0.0251732 0.0667605 3516.15 0.0502355 0.045831 0.0623464 -0.0112605 3521.43 0.0918213 -0.0249758 0.0292387 0.0851155 3526.7 0.10788 0.164473 0.138125 0.101636 3531.97 0.027533 0.17742 0.0710296 -0.04529 3537.24 0.0468601 0.0946792 0.0321803 0.011812 3542.51 0.0531317 0.0686338 0.0725557 0.112903 3547.79 0.0605535 0.0896039 0.0288417 0.0656326 3553.06 0.0120619 0.131136 -0.0230476 0.0612188 3558.33 0.14949 0.0317827 0.0957557 0.148865 3563.6 0.0787747 0.0576695 0.0417636 0.160202 3568.87 0.0080221 0.118864 0.120433 0.0854944 3574.15 0.0621356 0.0828707 0.049145 0.0415379 3579.42 0.111681 -0.018378 0.0339795 0.0455339 3584.69 0.10523 0.0783192 0.103008 0.0735789 3589.96 0.000602036 0.0585453 0.0979684 0.0621544 3595.23 0.00881866 0.0872386 0.0743352 -0.0316258 3600.51 0.105444 0.11339 0.0585471 0.0552463 3605.78 0.0697887 0.0323815 0.0595711 0.0714191 3611.05 -0.0302984 0.0481314 0.0759683 0.0924343 3616.32 0.053621 0.0663672 0.045055 0.0675227 3621.59 0.0693104 0.0819298 0.00609024 0.0312731 3626.87 0.0659401 0.077333 0.0173705 0.0518983 3632.14 -0.00326034 0.0597587 0.0278284 0.0488303 3637.41 0.00813841 0.0864352 0.0105628 0.0742277 3642.68 -0.0115004 0.0313315 0.0540009 0.058495 3647.95 0.0272326 0.085598 0.0824051 0.0531549 3653.23 0.0625481 0.0872901 0.0676212 0.0546201 3658.5 0.0569141 0.0517494 0.0436819 0.0825162 3663.77 0.0404172 0.0212205 0.0473001 0.0455416 3669.04 0.0547481 -0.00712515 0.0477973 0.0506385 3674.31 0.0357166 0.0206213 0.0566457 0.0776893 3679.59 -0.015277 0.030909 0.0531322 0.0368764 3684.86 0.012548 -0.00868777 0.0456371 0.0197461 3690.13 0.0643399 0.00864465 0.0975478 0.00760396 3695.4 0.0751977 0.00951752 0.0296315 0.0293212 3700.67 0.0697508 0.0406528 0.0149589 0.0650007 3705.95 0.0274078 0.0218524 0.0279721 0.0392246 3711.22 0.0309583 0.00212587 0.0419078 0.0347119 3716.49 0.0522953 0.0323578 0.0230529 0.00713196 3721.76 0.0673922 0.0337634 0.036652 0.0364313 3727.03 0.0739596 0.00393488 0.0650737 0.0436998 3732.31 0.0227083 0.0251617 0.0256886 0.0539601 3737.58 0.00577749 0.0175342 0.00396174 0.0210087 3742.85 0.034585 0.08583 0.00938629 0.0309311 3748.12 0.0202132 0.0260478 0.0403557 0.0235859 3753.4 -0.0035343 0.010767 0.02287 0.0213551 3758.67 0.0183967 0.0309969 0.0311539 0.0460621 3763.94 0.0199081 0.000661617 0.0196059 0.0266157 3769.21 -0.0159618 0.0264414 0.0238544 0.0369051 3774.48 -0.000992658 0.0515697 0.0400995 0.0469182 3779.76 0.0213248 0.015013 0.0259958 0.0260061 3785.03 -0.00371377 0.020563 0.00365254 0.00736992 3790.3 0.00906848 0.0606017 0.0157029 0.0129321 3795.57 0.0213761 0.0245566 0.0126782 0.0159728 3800.84 0.0267833 0.0443478 0.0263146 0.0362542 3806.12 0.0444299 0.0183291 0.0465919 0.0394626 3811.39 0.0130941 0.039339 0.0347108 0.0160007 3816.66 0.0151759 0.0100991 0.0227673 0.0135169 3821.93 0.0336319 0.0180551 0.039744 0.0227405 3827.2 0.0323362 0.00299952 0.017 0.0218564 3832.48 0.0205431 0.00939765 0.00884316 0.0259094 3837.75 0.00876748 0.0187203 0.0127617 0.0144046 3843.02 0.00879291 0.0135878 0.00227177 0.0164386 3848.29 0.00810286 0.00151832 0.000958248 0.00997382 3853.56 -0.000958918 -0.00541128 0.00392094 0.012022 3858.84 -0.00130835 0.00374528 0.0109941 0.0114727 3864.11 0.0244532 0.00147205 0.0258919 0.00381316 3869.38 0.0256577 0.0201866 0.0142933 0.032062 3874.65 0.0170337 0.0152702 -0.00326023 0.0337942 3879.92 0.0176111 0.0138324 0.0103931 0.0100313 3885.2 0.0121534 0.0228561 0.0207959 -0.00228913 3890.47 0.01851 0.0143846 0.00602671 0.0049712 3895.74 0.00239336 0.011085 0.00818643 0.0141118 3901.01 0.00026438 0.00779533 0.01068 0.0153011 3906.28 0.0131158 0.0165147 0.0108392 0.0209884 3911.56 0.0200969 0.019914 0.0193804 0.0184949 3916.83 0.0149179 0.0240202 0.0180033 0.0111807 3922.1 0.0165989 0.0119774 0.00554913 0.00690811 3927.37 0.0114332 0.0117991 0.00216355 0.00798228 3932.64 0.0166085 0.0155619 0.00778691 0.0019406 3937.92 0.0100221 0.0099652 0.0124623 -0.0011146 3943.19 0.00485285 0.00304109 0.00854939 0.00708795 3948.46 0.00931879 0.0093353 0.0023604 0.00885324 3953.73 0.0090981 0.00675965 0.00448072 0.00977277 3959 0.013004 0.0119104 0.00237537 0.00466072 3964.28 0.0081606 0.0112495 -0.00198198 0.00957579 3969.55 0.0079583 0.00504132 0.00524321 -0.00296926 3974.82 0.00135888 0.0103581 0.00617664 -0.00222856 3980.09 0.0120096 0.0121273 0.00425706 0.00353197 3985.36 0.0112455 0.00657859 0.00552346 0.00454449 3990.64 0.00237064 0.00356651 0.00941489 0.000301212 3995.91 0.0016049 0.000251599 0.00563238 -0.00280225 4001.18 0.00600356 0.00420452 0.00329947 0.00223064 4006.45 0.00391465 0.0057366 0.00549414 0.00565914 4011.72 0.0105512 0.00411007 0.00276709 0.000868588 4017 0.00943537 0.00218018 0.00541717 0.00260739 4022.27 0.00560619 0.00184004 0.00301811 0.00549854 4027.54 -0.00180378 0.00339723 0.00298727 0.00855975 4032.81 -0.000707977 0.00528452 0.00625165 0.0054404 4038.09 0.00430464 0.0057454 0.00609347 0.00171072 4043.36 0.00573541 0.00387403 -0.000606751 0.00288611 4048.63 0.00489633 -0.00258105 0.00100385 0.00188294 4053.9 0.00413715 -0.000621732 0.00205512 0.00104383 4059.17 0.000476806 0.000201179 0.00127688 0.000740861 4064.45 0.00333193 0.00115662 0.00207759 0.00332125 4069.72 0.00715732 0.00369958 0.00220898 0.0059583 4074.99 0.00294462 0.00281318 0.00110794 0.00460651 4080.26 -0.000526422 0.00365122 0.00202594 0.0061597 4085.53 0.00142172 0.00241685 0.00102801 0.00104069 4090.81 -7.55912e-05 0.00247928 0.00164742 0.000229638 4096.08 0.00297579 0.00220936 0.00442107 0.0014662 4101.35 0.00249813 0.00585182 0.00156263 0.00205049 4106.62 0.00191777 0.00404998 0.00223854 0.00111418 4111.89 0.00105797 0.00182305 0.00233144 0.00234665 4117.17 0.00548653 0.00348508 0.00184409 0.000839022 4122.44 0.00506778 0.00160447 0.00341988 0.00176277 4127.71 0.00321554 -0.00170803 0.00174193 0.00282786 4132.98 0.00363293 0.00131111 0.00154031 0.00287749 4138.25 0.00180619 0.000675261 0.00294181 0.00250619 4143.53 0.00302167 0.00210193 0.00236108 0.00341351 4148.8 0.0025947 0.00173141 0.00227092 0.00220921 4154.07 0.00188848 0.00290992 0.00121977 0.000673912 4159.34 0.00126153 0.000671637 0.00283789 0.00272703 4164.61 0.00163621 0.00204479 0.00160742 0.00203276 4169.89 0.00220521 0.00345352 0.000553377 0.00231182 4175.16 0.00395924 0.00252494 0.000690734 0.00152022 4180.43 0.00277852 0.00130943 -4.77321e-05 0.000801033 4185.7 0.00283179 0.00218587 0.00255673 0.00123447 4190.97 0.00292508 0.00295599 0.00235075 0.0011134 4196.25 0.00223557 0.00123827 0.000585608 0.00226207 4201.52 0.00303754 0.00285895 0.00180243 0.0014408 4206.79 0.00293169 0.00406803 0.00175199 0.000277936 4212.06 0.00243749 0.00218684 0.000879603 0.000655759 4217.33 0.00300945 0.000371033 0.000736047 0.00234342 4222.61 0.00142611 0.000601247 0.000384232 0.00153176 4227.88 9.36376e-05 0.00169046 0.000549611 0.000837004 4233.15 0.00083774 0.000618484 0.00129018 0.000854058 4238.42 0.00086544 0.000983982 0.00166882 0.00093778 4243.69 0.00211063 0.00207923 0.0018168 0.000691891 4248.97 0.00211206 0.00185068 0.000745393 0.00218568 4254.24 0.00112899 0.001289 -0.00016867 0.00103995 4259.51 0.000819649 0.00104273 0.00276161 0.000260841 4264.78 -0.000408924 0.00199265 0.00157036 0.000916515 4270.05 0.002011 0.00193623 0.00138984 0.0012904 4275.33 0.00158877 0.00139298 0.000681967 0.00174328 4280.6 0.00161733 0.00113075 0.00077865 0.000917133 4285.87 0.00148243 0.00154923 0.00055519 0.00114272 4291.14 -0.000792808 0.00112516 0.000321816 0.00198983 4296.41 -0.00157768 0.00276901 0.000430121 0.00230432 4301.69 -0.000906087 0.00208033 0.000946345 0.00216475 4306.96 0.00141342 0.000380718 0.00118689 0.00204783 4312.23 0.000441695 -3.61763e-05 0.00172649 0.00173826 4317.5 0.000912275 0.00182667 0.00153847 0.000779044 4322.78 0.000777463 0.00166314 0.000771501 0.000269416 4328.05 0.00125794 0.00130603 0.00125491 0.00057017 4333.32 0.00133085 0.00010891 0.00112673 0.00136355 4338.59 0.00141623 0.00115532 0.000589856 0.000768101 4343.86 0.00185025 0.0015437 0.00103622 0.00087546 4349.14 0.00190567 0.000774144 0.00113634 0.00120786 4354.41 0.00180582 0.000998693 0.00076639 0.000887941 4359.68 0.00114101 0.00102833 -0.000319756 0.000711256 4364.95 0.000888104 0.00108623 -0.000410866 0.00178423 4370.22 0.00189217 0.000732568 0.00111929 -0.00027996 4375.5 0.002303 0.000287565 0.00146044 0.00197842 4380.77 0.000968447 0.000597215 0.00135999 0.00219879 4386.04 0.000214261 0.00110337 0.00137817 0.00145518 4391.31 0.00154682 0.0015071 0.00110968 0.00165221 4396.58 0.00138955 0.00010917 0.000544131 0.000479295 4401.86 0.000321807 0.00135864 6.30964e-05 0.00118074 4407.13 0.00134982 0.00130198 0.00130977 0.00174315 4412.4 0.000521314 0.000770354 0.000214391 0.000975042 4417.67 0.00148906 0.0011452 -1.47769e-05 0.000306777 4422.94 0.00193398 0.000694243 0.000634642 0.000627091 4428.22 0.00149635 0.000241415 0.000258191 0.00159039 4433.49 0.000853086 0.00090361 0.00112918 0.00181611 4438.76 0.000791319 0.00159516 0.00117147 0.00127443 4444.03 0.000589986 0.000635517 0.000597401 0.000682166 4449.3 -1.54294e-05 0.000810666 0.000580811 0.00103048 4454.58 0.000741984 0.000979422 9.77783e-06 0.00116442 4459.85 0.000853649 0.00100134 -7.76367e-05 0.00122369 4465.12 0.000667296 0.000303369 0.000277877 0.000619683 4470.39 -3.22564e-05 0.00132818 0.00153698 0.000552472 4475.66 0.000338479 0.00074707 0.00026673 0.00068318 4480.94 0.00130802 0.00146641 0.000399436 0.00133262 4486.21 -0.000228368 0.000995905 0.00137152 0.00123524 4491.48 0.000282689 0.000903425 0.0014647 0.000670888 4496.75 0.0002523 0.00134089 0.00054735 0.000926428 4502.02 0.00147954 0.00130669 0.000659439 0.000492022 4507.3 0.000995622 0.000897522 0.000376855 0.000574005 4512.57 0.000927671 0.00132456 0.000737478 0.0014065 4517.84 0.00079514 0.000851259 0.00126045 0.00121169 4523.11 0.00123235 0.000379382 0.000990504 0.00134304 4528.38 0.00124382 0.00123247 0.000618175 0.00136874 4533.66 0.00072965 0.000661998 0.000539041 0.00113739 4538.93 0.00106114 0.000582243 0.000708565 0.000823869 4544.2 0.0014707 0.000987996 0.000707573 0.000598172 4549.47 0.00132006 0.0010998 0.0005296 0.000561986 4554.74 0.000616707 0.00118339 0.000517047 0.00137645 4560.02 0.00132803 0.000922521 0.000668956 0.00080476 4565.29 0.00142414 0.000844446 0.0012957 0.000843227 4570.56 0.00116371 0.000835312 0.00127616 0.000305742 4575.83 0.000514984 0.000895304 0.000654428 0.000751978 4581.1 0.000778956 0.00101422 0.000550637 0.00144181 4586.38 0.000929617 0.00170544 0.00056135 0.000534891 4591.65 0.000829347 0.00146012 0.000491765 0.0013214 4596.92 0.00118504 0.00117832 0.000674905 0.00128231 4602.19 0.000475212 0.000531926 0.00105053 0.000636595 4607.47 -5.66114e-05 0.000869844 0.000596995 -0.000207508 4612.74 0.000983722 0.000831992 0.000531314 0.000464783 4618.01 0.000471455 0.000588691 0.000643132 0.000613527 4623.28 0.000466124 0.000197485 0.000634984 0.000966428 4628.55 0.00113497 -0.000146273 0.000494532 0.00070367 4633.83 0.000848032 0.000679653 0.000279763 0.0013421 4639.1 0.000904018 0.000743527 0.000488964 0.000840966 4644.37 0.000847522 0.000421302 0.000917898 0.000813679 4649.64 0.001419 0.000711797 0.000915675 0.00123635 4654.91 0.00137646 0.000318427 0.000619937 0.000813922 4660.19 0.000672845 0.000333205 0.000972037 0.000764342 4665.46 0.000688517 0.000426425 0.000817697 0.000642001 4670.73 0.0010218 0.00078148 0.0008946 0.00110734 4676 0.0012954 0.000867728 0.000759204 0.000702196 4681.27 0.000959125 8.22206e-05 0.000886965 0.000755707 4686.55 0.000756329 0.000479316 0.00110588 0.00098678 4691.82 0.000825603 0.000714493 0.000922354 0.00061524 4697.09 0.00119506 0.000862784 0.000650475 0.000724808 4702.36 0.000913595 0.000521716 0.00120486 0.000825535 4707.63 0.00122005 0.0003121 0.000914382 0.000723712 4712.91 0.00119787 0.00121164 0.000547712 0.0010182 4718.18 0.00021557 0.000899723 0.000353647 0.00102853 4723.45 4.44017e-05 0.000170311 0.000696905 0.000553911 4728.72 0.000913537 0.000479217 0.000704943 0.000894932 4733.99 0.00113214 0.00149424 0.0017282 0.00114305 4739.27 0.000593449 0.00119635 0.00169527 0.00149887 4744.54 0.00091611 0.000977 0.00207335 0.00175408 4749.81 0.00122031 0.000893732 0.00257265 0.00222677 4755.08 0.000737184 0.000481486 0.00304725 0.00259118 4760.35 0.00114046 0.000718072 0.00301676 0.00340421 4765.63 0.000799087 0.00124769 0.00383367 0.00411371 4770.9 0.000714958 0.00079725 0.0039774 0.00602576 4776.17 0.0014129 0.00085695 0.00363486 0.00720348 4781.44 0.000679406 0.00098051 0.00326965 0.00780812 4786.71 0.00078454 0.000979345 0.00358596 0.00810251 4791.99 0.000958041 0.00117925 0.00358205 0.00834157 4797.26 0.000445623 0.000896685 0.00392554 0.00825456 4802.53 0.00025717 0.000778472 0.00397507 0.00844577 4807.8 0.000778524 0.00108409 0.00357439 0.00875691 4813.07 0.00120096 0.00132478 0.00425269 0.00868831 4818.35 0.00142211 0.00109009 0.00375266 0.00857736 4823.62 0.00155852 0.000897982 0.00410121 0.00845341 4828.89 0.00135303 0.00151661 0.00434537 0.00866365 4834.16 0.00155077 0.00194759 0.00515174 0.00854352 4839.43 0.00186465 0.00249097 0.00545594 0.00877635 4844.71 0.00322586 0.00277459 0.00664512 0.00922139 4849.98 0.00345838 0.00313111 0.00724781 0.0096247 4855.25 0.00452723 0.00428078 0.00889469 0.010241 4860.52 0.0059954 0.00661857 0.0108307 0.0104682 4865.79 0.00748183 0.00848784 0.0131344 0.0114186 4871.07 0.0104826 0.010332 0.0161158 0.0126557 4876.34 0.0136013 0.0135009 0.0197632 0.0140443 4881.61 0.0168436 0.0170611 0.0247137 0.0163138 4886.88 0.0213538 0.0214817 0.0311077 0.0190459 4892.16 0.0255942 0.0255952 0.0372795 0.0219187 4897.43 0.0304822 0.0321168 0.0445621 0.0265118 4902.7 0.0355498 0.0394802 0.0525334 0.0324039 4907.97 0.0412683 0.0468324 0.0617561 0.0397224 4913.24 0.0489721 0.0540938 0.0726234 0.0480842 4918.52 0.0552377 0.0652724 0.0817277 0.0566585 4923.79 0.0644799 0.0744236 0.0933926 0.0652832 4929.06 0.0751842 0.0885561 0.108154 0.0760973 4934.33 0.088451 0.0990661 0.123432 0.0875985 4939.6 0.103957 0.111839 0.135395 0.0998242 4944.88 0.11642 0.127178 0.152794 0.112093 4950.15 0.129654 0.141689 0.172477 0.126481 4955.42 0.142361 0.156897 0.18954 0.143818 4960.69 0.155554 0.173309 0.206052 0.15928 4965.96 0.17056 0.192116 0.223707 0.175295 4971.24 0.185777 0.209012 0.239138 0.191709 4976.51 0.20299 0.227166 0.259599 0.212047 4981.78 0.220406 0.245891 0.281764 0.232277 4987.05 0.241091 0.263586 0.299735 0.248634 4992.32 0.262722 0.2807 0.320421 0.26816 4997.6 0.281069 0.298317 0.343636 0.288669 5002.87 0.298812 0.320331 0.36171 0.309235 5008.14 0.31795 0.342284 0.378666 0.328243 5013.41 0.333898 0.361154 0.398532 0.346749 5018.68 0.347626 0.380465 0.415838 0.36602 5023.96 0.363919 0.399467 0.434252 0.381276 5029.23 0.379662 0.416506 0.454403 0.399347 5034.5 0.399294 0.438406 0.471798 0.417105 5039.77 0.417917 0.454099 0.487748 0.436537 5045.04 0.435077 0.473758 0.505211 0.45428 5050.32 0.457114 0.489657 0.52348 0.467262 5055.59 0.475017 0.507612 0.54204 0.487795 5060.86 0.494129 0.519375 0.55406 0.506109 5066.13 0.509217 0.533935 0.565929 0.522675 5071.4 0.523829 0.548706 0.580485 0.541503 5076.68 0.539951 0.560014 0.595335 0.556764 5081.95 0.558149 0.574853 0.606998 0.568719 5087.22 0.574984 0.590077 0.623285 0.580286 5092.49 0.588419 0.600534 0.633442 0.5946 5097.76 0.610064 0.610527 0.642628 0.607923 5103.04 0.623738 0.623769 0.655842 0.618764 5108.31 0.631351 0.637259 0.668927 0.625707 5113.58 0.639419 0.649012 0.67867 0.632572 5118.85 0.649045 0.66098 0.689602 0.643279 5124.12 0.661794 0.671845 0.699293 0.652357 5129.4 0.671384 0.683356 0.706586 0.662307 5134.67 0.678275 0.695576 0.713263 0.66542 5139.94 0.690522 0.703966 0.720261 0.672761 5145.21 0.704294 0.710748 0.730733 0.674184 5150.48 0.722278 0.717667 0.739812 0.680898 5155.76 0.738062 0.725288 0.746321 0.688277 5161.03 0.744287 0.739874 0.756474 0.696566 5166.3 0.74926 0.746233 0.762428 0.706183 5171.57 0.754217 0.748425 0.770725 0.712035 5176.85 0.758896 0.759304 0.779103 0.721673 5182.12 0.763736 0.764016 0.782514 0.730089 5187.39 0.76737 0.764917 0.782948 0.738662 5192.66 0.770591 0.770866 0.79069 0.743536 5197.93 0.771953 0.776535 0.796024 0.74936 5203.21 0.779344 0.787855 0.796629 0.757602 5208.48 0.788255 0.788045 0.804968 0.763742 5213.75 0.790937 0.788106 0.809445 0.764068 5219.02 0.796932 0.791756 0.808669 0.771335 5224.29 0.799384 0.795226 0.818253 0.774559 5229.57 0.801604 0.800729 0.822015 0.778824 5234.84 0.802434 0.803844 0.821819 0.781762 5240.11 0.806709 0.805539 0.82428 0.782977 5245.38 0.803063 0.80864 0.827335 0.795326 5250.65 0.803988 0.815128 0.83494 0.795438 5255.93 0.8093 0.81881 0.834668 0.796696 5261.2 0.813258 0.813549 0.838062 0.806589 5266.47 0.820721 0.815778 0.842114 0.81002 5271.74 0.82263 0.822926 0.846484 0.820264 5277.01 0.822304 0.827321 0.848162 0.822378 5282.29 0.824325 0.82698 0.846818 0.824684 5287.56 0.827093 0.827562 0.852653 0.832152 5292.83 0.829516 0.829913 0.853535 0.825657 5298.1 0.83691 0.832136 0.855375 0.831469 5303.37 0.836882 0.835948 0.858787 0.834777 5308.65 0.843489 0.836746 0.863236 0.833579 5313.92 0.842463 0.840509 0.863843 0.831082 5319.19 0.848901 0.84221 0.866826 0.833144 5324.46 0.855568 0.846203 0.875406 0.832955 5329.73 0.855944 0.851111 0.880759 0.831703 5335.01 0.857209 0.855357 0.881091 0.836941 5340.28 0.859075 0.859316 0.875235 0.840689 5345.55 0.862838 0.861337 0.879098 0.842322 5350.82 0.862722 0.864467 0.885489 0.841884 5356.09 0.867073 0.868864 0.888094 0.843199 5361.37 0.871365 0.870939 0.888748 0.850524 5366.64 0.873335 0.871956 0.891606 0.851773 5371.91 0.879023 0.876749 0.895119 0.85056 5377.18 0.882771 0.881027 0.900347 0.851455 5382.45 0.888213 0.87829 0.903611 0.856321 5387.73 0.89249 0.874169 0.900697 0.858858 5393 0.891089 0.877555 0.90124 0.863571 5398.27 0.888894 0.876714 0.904107 0.867919 5403.54 0.890916 0.885604 0.904359 0.872237 5408.81 0.888651 0.884512 0.903228 0.873879 5414.09 0.887629 0.88393 0.90593 0.873107 5419.36 0.889191 0.884731 0.906999 0.874425 5424.63 0.891319 0.883078 0.906443 0.874915 5429.9 0.893938 0.884415 0.908424 0.874876 5435.17 0.888374 0.887704 0.91266 0.876792 5440.45 0.894657 0.890325 0.917326 0.881166 5445.72 0.895479 0.887928 0.912004 0.881786 5450.99 0.896963 0.888294 0.910258 0.881891 5456.26 0.895895 0.882739 0.911343 0.880254 5461.54 0.891344 0.884185 0.910722 0.879095 5466.81 0.890454 0.885157 0.906023 0.883849 5472.08 0.88948 0.8912 0.904429 0.883018 5477.35 0.890229 0.889359 0.908815 0.881459 5482.62 0.890665 0.892358 0.910319 0.879942 5487.9 0.885351 0.892787 0.904214 0.880496 5493.17 0.885337 0.891542 0.907856 0.879854 5498.44 0.885442 0.890271 0.909334 0.882973 5503.71 0.882723 0.88841 0.910544 0.887027 5508.98 0.88413 0.890384 0.909106 0.882202 5514.26 0.882874 0.890744 0.910756 0.882496 5519.53 0.880461 0.892501 0.910501 0.883654 5524.8 0.881327 0.892979 0.907289 0.880323 5530.07 0.881166 0.892994 0.912473 0.878003 5535.34 0.882535 0.894232 0.911937 0.879841 5540.62 0.886383 0.89097 0.910065 0.878796 5545.89 0.886883 0.895068 0.911583 0.881664 5551.16 0.886657 0.899529 0.91651 0.880553 5556.43 0.889166 0.898822 0.917979 0.876808 5561.7 0.88924 0.893341 0.914049 0.875277 5566.98 0.886766 0.893538 0.913764 0.876638 5572.25 0.888444 0.89565 0.913777 0.876429 5577.52 0.890301 0.892277 0.91374 0.876526 5582.79 0.891398 0.893204 0.912159 0.874063 5588.06 0.889399 0.891118 0.910475 0.871063 5593.34 0.889046 0.887689 0.913278 0.874205 5598.61 0.891791 0.891972 0.912418 0.87714 5603.88 0.89358 0.896231 0.906598 0.879153 5609.15 0.890402 0.894445 0.910843 0.876234 5614.42 0.886173 0.894388 0.91085 0.876791 5619.7 0.888322 0.894469 0.908028 0.876167 5624.97 0.891196 0.891038 0.908514 0.870127 5630.24 0.898962 0.894103 0.911729 0.870525 5635.51 0.89786 0.89174 0.913389 0.867844 5640.78 0.893899 0.887655 0.913458 0.865233 5646.06 0.895206 0.888015 0.911695 0.86485 5651.33 0.896394 0.887136 0.906492 0.867277 5656.6 0.895297 0.88075 0.910274 0.867934 5661.87 0.895278 0.879424 0.908166 0.864463 5667.14 0.896328 0.881107 0.902211 0.866471 5672.42 0.893396 0.881289 0.902578 0.869879 5677.69 0.89294 0.879797 0.899189 0.87228 5682.96 0.890908 0.875924 0.899589 0.874881 5688.23 0.888879 0.874953 0.900602 0.875655 5693.5 0.888215 0.880573 0.900436 0.876193 5698.78 0.886169 0.878655 0.898957 0.875243 5704.05 0.886769 0.878942 0.898635 0.876749 5709.32 0.887508 0.883418 0.903598 0.879452 5714.59 0.886586 0.882424 0.901029 0.875755 5719.86 0.885395 0.881905 0.898544 0.872243 5725.14 0.885354 0.878516 0.896179 0.872945 5730.41 0.886982 0.878524 0.898243 0.870097 5735.68 0.885632 0.878448 0.893443 0.865549 5740.95 0.883312 0.874169 0.890443 0.865138 5746.23 0.88194 0.870548 0.890716 0.860602 5751.5 0.880629 0.871542 0.887929 0.859336 5756.77 0.877819 0.870671 0.886069 0.854689 5762.04 0.875487 0.86657 0.882128 0.851734 5767.31 0.874425 0.867055 0.883073 0.84774 5772.59 0.870559 0.864065 0.877269 0.845595 5777.86 0.870474 0.856352 0.872425 0.840175 5783.13 0.86759 0.85311 0.871155 0.833199 5788.4 0.865146 0.853423 0.86694 0.82756 5793.67 0.86632 0.852474 0.870666 0.822058 5798.95 0.860511 0.845956 0.866014 0.816467 5804.22 0.857338 0.843711 0.863214 0.80898 5809.49 0.856858 0.843917 0.860004 0.79981 5814.76 0.859512 0.843422 0.859013 0.799442 5820.03 0.85446 0.838958 0.85476 0.801964 5825.31 0.853463 0.829665 0.844294 0.795447 5830.58 0.846854 0.824639 0.830225 0.790338 5835.85 0.835778 0.811294 0.81072 0.790746 5841.12 0.818071 0.785712 0.788114 0.792895 5846.39 0.797414 0.763245 0.75696 0.790509 5851.67 0.77228 0.73854 0.728156 0.783366 5856.94 0.742992 0.705144 0.697188 0.774427 5862.21 0.713845 0.670849 0.662423 0.758525 5867.48 0.680948 0.637646 0.628086 0.741971 5872.75 0.648846 0.604217 0.594243 0.722613 5878.03 0.613947 0.572598 0.56093 0.694972 5883.3 0.579753 0.536052 0.526475 0.665204 5888.57 0.547364 0.504813 0.490924 0.637746 5893.84 0.514199 0.471017 0.45675 0.611493 5899.11 0.481768 0.438397 0.424105 0.582059 5904.39 0.448054 0.407609 0.391812 0.553185 5909.66 0.414367 0.376313 0.359477 0.524202 5914.93 0.383002 0.346048 0.32634 0.492745 5920.2 0.351503 0.315506 0.295142 0.465566 5925.47 0.318256 0.284243 0.263469 0.43698 5930.75 0.287438 0.254275 0.231045 0.406261 5936.02 0.255804 0.222086 0.199763 0.377213 5941.29 0.221246 0.19099 0.166733 0.34755 5946.56 0.186437 0.158025 0.133545 0.316685 5951.83 0.151905 0.125522 0.104402 0.286916 5957.11 0.12082 0.0968665 0.0784683 0.255295 5962.38 0.0927999 0.0721277 0.0575535 0.222281 5967.65 0.0702635 0.0522885 0.0417795 0.190465 5972.92 0.0523716 0.0375439 0.03049 0.157834 5978.19 0.0387604 0.0276301 0.022334 0.126165 5983.47 0.0295135 0.0206475 0.0166701 0.0992194 5988.74 0.0227007 0.0153688 0.0132645 0.07636 5994.01 0.0172717 0.0117979 0.0104276 0.0577411 5999.28 0.0137262 0.00916501 0.0081298 0.0438612 6004.55 0.0109015 0.00745606 0.00685491 0.0331885 6009.83 0.00864293 0.00606872 0.00546992 0.0255976 6015.1 0.00681052 0.00498615 0.0044563 0.0199398 6020.37 0.00597626 0.00422429 0.0038713 0.0159079 6025.64 0.00488145 0.00321143 0.00332157 0.0129663 6030.92 0.00392903 0.00267264 0.0026559 0.0100122 6036.19 0.00339109 0.00231937 0.00210071 0.00786176 6041.46 0.00278666 0.00197092 0.00178607 0.00641348 6046.73 0.00226028 0.00180946 0.00160912 0.00553143 6052 0.00184911 0.00161231 0.00141267 0.00452045 6057.28 0.00160145 0.00139933 0.00116015 0.00362554 6062.55 0.00141365 0.00110407 0.00100338 0.00306852 6067.82 0.00127035 0.000874334 0.000867906 0.00252391 6073.09 0.00105926 0.000746303 0.000745288 0.00202815 6078.36 0.000957636 0.000622947 0.000664953 0.00173173 6083.64 0.000821101 0.000597167 0.00065315 0.00153668 6088.91 0.000670963 0.000720122 0.000674778 0.00141835 6094.18 0.000539262 0.000569851 0.000528721 0.00128966 6099.45 0.000502765 0.000459054 0.000380842 0.00100771 6104.72 0.00043333 0.000484644 0.000356664 0.000843566 6110 0.000352799 0.000491294 0.000406361 0.000806063 6115.27 0.000424779 0.000372605 0.000389319 0.000738527 6120.54 0.000473291 0.000427374 0.000333033 0.000646553 6125.81 0.000453007 0.000378422 0.000293974 0.000634201 6131.08 0.00035626 0.000367673 0.000332003 0.000532882 6136.36 0.000372208 0.00035063 0.000238919 0.000552336 6141.63 0.000373877 0.000273817 0.00028626 0.000479265 6146.9 0.000311538 0.000404552 0.00036459 0.000420108 6152.17 0.000245657 0.000321994 0.000335887 0.000456981 6157.44 0.000337489 0.000235999 0.000158704 0.000292888 6162.72 0.000300946 0.000303507 0.000154582 0.000310081 6167.99 0.000346343 0.00030602 0.000262026 0.000334634 6173.26 0.000223267 0.000337392 0.000151407 0.000341367 6178.53 8.24867e-05 0.000319424 0.000170089 0.000315961 6183.8 0.000240649 0.000259731 0.000193177 0.00032512 6189.08 0.000258721 0.000206254 0.000141282 0.000247068 6194.35 0.000115504 0.00021435 0.000216768 0.000185099 6199.62 0.000216992 0.000269459 0.000181718 0.000237908 6204.89 0.000240578 0.00019588 0.000197077 0.00025189 6210.16 0.00013847 0.000189666 0.000272981 0.000240691 6215.44 0.000197133 0.000240764 0.000161323 0.000236126 6220.71 0.000226508 0.000168273 0.00026361 0.000206902 6225.98 0.000276221 0.000121666 0.00026798 0.000165288 6231.25 0.000172788 0.000255971 0.000187138 0.000180605 6236.52 0.000178671 0.000227924 0.000156827 0.00017953 6241.8 0.000186526 0.00013086 0.000134168 0.000250585 6247.07 0.000175622 0.000136207 0.000135351 0.000250536 6252.34 0.000178427 0.000227067 0.000127574 0.000157807 6257.61 0.00018263 0.000200319 0.000136784 0.000152608 6262.88 0.000176022 5.89945e-05 0.000133104 0.000128284 6268.16 0.00011584 5.67923e-05 0.000218686 8.30832e-05 6273.43 0.00012581 0.000102767 0.000250208 8.6037e-05 6278.7 0.0001476 0.000202859 0.000207597 0.0001394 6283.97 7.81121e-05 0.000185865 0.000230704 0.000105104 6289.24 6.0215e-05 0.000143529 0.000224872 9.64841e-05 6294.52 0.000171736 0.000159957 9.72274e-05 0.000160281 6299.79 0.000174713 0.000173255 6.11452e-05 0.000153945 6305.06 9.63059e-05 0.000183203 6.68984e-05 0.000144535 6310.33 5.62707e-05 0.000183412 0.000108554 0.000167354 6315.61 4.76901e-05 0.000123973 0.000130821 0.000175236 6320.88 0.000157482 0.000136008 0.000195254 0.000173077 6326.15 3.54023e-05 7.60384e-05 9.93842e-05 0.000120402 6331.42 1.29587e-05 9.44785e-05 0.000130491 4.48483e-05 6336.69 1.51778e-05 6.12557e-05 6.17716e-05 8.12798e-05 6341.97 8.88964e-05 0.000100356 8.46079e-05 7.06818e-05 6347.24 6.69698e-05 0.000139103 0.00019598 0.00012197 6352.51 0.000146858 3.80514e-05 0.000194958 9.00656e-05 6357.78 6.06493e-05 4.6223e-05 8.14412e-05 0.000151782 6363.05 9.97028e-05 0.000115308 7.66837e-05 0.000110555 6368.33 0.000216072 8.88489e-05 9.8875e-05 0.000108868 6373.6 0.000115992 4.35736e-05 0.000135934 0.000123459 6378.87 9.66899e-05 0.000190596 5.92985e-05 6.98918e-05 6384.14 0.000165855 0.000125113 3.33447e-05 4.78822e-05 6389.41 6.35554e-05 7.58026e-05 7.76728e-05 0.00010072 6394.69 8.41358e-05 0.000152491 0.000117995 7.93309e-05 6399.96 0.000119387 5.85803e-05 5.40199e-05 7.24739e-05 6405.23 4.11537e-05 8.44431e-06 -2.51078e-05 9.19771e-05 6410.5 0.000115322 9.2524e-05 5.55761e-05 8.37391e-05 6415.77 0.000225475 0.000101672 0.000130352 9.77734e-05 6421.05 0.000145415 3.6766e-05 0.000117016 5.15879e-05 6426.32 7.49143e-05 -1.57714e-05 0.000128909 4.26255e-05 6431.59 0.000105709 5.56699e-05 0.000157352 7.27861e-05 6436.86 0.000104311 0.000113694 0.000158883 2.8931e-05 6442.13 0.000123713 5.03695e-05 0.000147517 8.69877e-05 6447.41 3.1757e-05 3.30833e-05 0.000116049 0.000126569 6452.68 9.16294e-06 0.000106157 8.62753e-05 9.53432e-05 6457.95 0.000121285 9.3258e-05 6.0486e-05 5.98477e-05 6463.22 6.19926e-05 0.000130366 0.000118652 1.83493e-05 6468.49 1.40019e-05 0.000110418 6.79985e-05 4.43125e-05 6473.77 4.40578e-05 0.000118312 2.06849e-05 9.85164e-05 6479.04 0.000111451 0.000112528 6.72523e-05 9.17591e-05 6484.31 0.000155696 5.97056e-05 6.00413e-05 0.000112954 6489.58 0.000113849 4.86989e-05 6.97107e-05 6.4191e-05 6494.85 0.000110442 2.27968e-05 0.000105816 0.000115757 6500.13 6.36667e-05 1.4174e-05 0.000109997 4.79438e-05 6505.4 6.0559e-05 5.80898e-05 8.79529e-05 9.84455e-05 6510.67 0.000110869 4.99378e-05 9.97264e-05 0.000113152 6515.94 0.000109114 8.40428e-05 1.91903e-05 7.73897e-05 6521.21 0.000134822 0.000120966 5.47625e-05 5.40534e-05 6526.49 0.000100859 7.2283e-05 8.22806e-05 5.82014e-05 6531.76 7.86999e-05 0.000114876 0.000159591 2.72369e-05 6537.03 0.000113319 0.00011415 8.28934e-05 5.80211e-05 6542.3 0.000118858 8.61692e-05 6.33517e-05 7.61976e-05 6547.57 9.12142e-05 6.57012e-05 7.37073e-05 8.14728e-05 6552.85 8.42381e-05 5.62153e-05 3.70491e-05 6.10796e-05 6558.12 4.55715e-05 4.99191e-05 9.22896e-05 5.1489e-05 6563.39 1.18601e-05 0.00013138 0.000115294 7.58632e-05 6568.66 6.77896e-05 7.22427e-05 7.18358e-05 6.47955e-05 6573.93 6.11122e-05 8.19974e-05 7.50591e-05 5.32968e-05 6579.21 5.12959e-05 8.90264e-05 9.95627e-05 1.48598e-05 6584.48 7.9932e-05 5.37166e-05 8.83868e-05 5.1669e-05 6589.75 1.27527e-05 8.27953e-05 1.92236e-05 0.000107583 6595.02 8.17639e-05 8.69249e-05 -6.60809e-06 4.95144e-05 6600.3 3.01954e-05 0.000123379 6.15544e-05 0.000108037 6605.57 8.64751e-05 5.29726e-05 2.99568e-05 1.36514e-05 6610.84 0.000154108 3.52295e-05 6.22279e-05 2.24769e-05 6616.11 7.91532e-05 3.68287e-05 6.86027e-05 -4.9288e-05 6621.38 2.23611e-05 5.17415e-05 -1.41694e-05 3.37292e-05 6626.66 0.00010515 -1.64635e-05 6.95889e-05 8.22614e-05 6631.93 9.7309e-05 3.43238e-05 0.000117979 2.05596e-05 6637.2 2.23801e-07 9.06596e-05 9.50992e-05 5.47196e-05 6642.47 5.22207e-05 0.000103049 -4.56022e-05 4.55336e-05 6647.74 7.16981e-05 7.65293e-05 2.56835e-05 6.16916e-06 6653.02 6.45355e-05 9.49372e-06 4.67919e-05 3.82995e-05 6658.29 4.79345e-05 2.12456e-05 -1.88783e-05 4.78336e-05 6663.56 2.429e-05 5.3412e-05 -1.62175e-05 3.26356e-05 6668.83 7.13858e-05 1.91944e-05 5.31457e-05 6.78694e-05 6674.1 0.000153238 5.37185e-05 3.57749e-05 3.46242e-05 6679.38 0.000129009 0.000118805 7.31938e-05 3.50046e-05 6684.65 4.99641e-05 3.75009e-05 0.000132586 6.69414e-05 6689.92 8.1192e-05 3.6845e-05 7.83138e-05 5.79881e-05 6695.19 8.93429e-05 4.54945e-05 7.93633e-05 6.86948e-06 6700.46 5.04478e-05 9.0426e-05 0.000100231 2.39388e-05 6705.74 9.21131e-05 0.000110971 7.89628e-05 6.98409e-05 6711.01 6.20534e-05 -5.40754e-06 5.96202e-05 6.17779e-05 6716.28 -4.14851e-05 4.30782e-05 2.40974e-05 9.01214e-05 6721.55 -1.66355e-07 7.38716e-05 5.20383e-05 0.000103851 6726.82 7.52667e-05 1.76634e-05 7.10084e-05 7.05694e-05 6732.1 -5.28531e-06 0.000119754 5.2098e-05 5.44364e-05 6737.37 4.48049e-05 1.97019e-06 9.57126e-05 3.70194e-05 6742.64 8.12984e-05 6.29684e-05 8.93528e-05 6.30356e-05 6747.91 9.86499e-05 4.88591e-05 6.99389e-05 7.01711e-05 6753.18 7.52145e-05 6.07512e-05 5.58431e-05 8.54863e-05 6758.46 0.000109218 6.81772e-05 5.65704e-05 7.45402e-05 6763.73 -2.55164e-05 6.43628e-05 7.4818e-05 7.34378e-05 6769 -2.84769e-05 4.67094e-05 7.27174e-05 0.000107941 6774.27 8.96948e-05 -7.90516e-06 7.28124e-05 3.28925e-05 6779.54 7.10621e-05 -1.45702e-05 2.56344e-05 9.781e-06 6784.82 7.69007e-05 2.25832e-07 2.17015e-05 3.57779e-05 6790.09 4.07635e-05 -1.56335e-05 1.08227e-05 4.80246e-05 6795.36 5.17499e-06 1.62055e-05 2.77333e-05 2.28109e-05 6800.63 6.79683e-05 6.22809e-05 8.23819e-05 6.0041e-05 6805.9 -1.5585e-05 6.16132e-05 7.11163e-05 5.04823e-05 6811.18 7.23215e-05 3.79002e-05 7.57716e-05 5.17793e-05 6816.45 7.14212e-05 5.70599e-05 7.07174e-05 4.72683e-05 6821.72 5.2706e-05 6.41437e-05 5.38102e-05 3.67071e-05 6826.99 0.00010447 1.50321e-05 2.1387e-05 1.16175e-05 6832.26 8.03973e-05 4.65887e-05 4.81429e-05 5.41435e-05 6837.54 5.77899e-05 6.51871e-05 5.12941e-05 2.50454e-06 6842.81 5.77615e-05 5.65564e-05 6.77596e-05 1.8469e-05 6848.08 9.06333e-05 2.66456e-05 5.76944e-05 3.74543e-05 6853.35 -1.71202e-05 3.2333e-05 3.94248e-05 2.28389e-05 6858.62 -6.27826e-05 1.72556e-05 3.76844e-05 6.52109e-05 6863.9 8.60021e-05 -6.52377e-06 1.23324e-05 6.96926e-05 6869.17 1.47839e-05 2.78549e-05 3.25769e-05 3.13118e-05 6874.44 7.99037e-06 -7.67744e-06 4.50411e-05 4.05253e-05 6879.71 0.000100635 6.84422e-05 2.61509e-05 7.65714e-05 6884.99 5.99493e-05 5.06232e-05 5.42537e-05 7.82041e-05 6890.26 0.000103155 -1.05781e-05 5.72377e-05 7.21633e-05 6895.53 4.28291e-06 3.91529e-05 5.18073e-05 2.74737e-05 6900.8 5.60335e-05 -7.34299e-06 5.66561e-05 -1.72759e-05 6906.07 5.17161e-05 5.70539e-06 1.9005e-05 -5.1987e-05 6911.35 2.48012e-05 3.10114e-05 3.76585e-05 -9.47401e-06 6916.62 0.00011213 6.42592e-05 7.56575e-05 1.18779e-05 6921.89 6.41932e-05 1.22013e-05 -7.03939e-06 3.92893e-05 6927.16 5.25834e-05 9.31618e-06 1.60715e-05 8.69414e-05 6932.43 9.727e-05 1.80906e-05 2.08832e-05 3.40344e-05 6937.71 -1.57726e-05 3.31837e-05 -9.42195e-06 4.47012e-05 6942.98 3.39535e-05 5.34844e-05 -1.421e-05 6.39499e-06 6948.25 4.53917e-05 7.17917e-05 4.42595e-05 2.34983e-05 6953.52 5.23229e-05 0.000114417 1.74921e-05 1.88049e-05 6958.79 8.77072e-05 8.90234e-05 1.12279e-05 -3.06461e-05 6964.07 9.43526e-05 3.90976e-05 2.44044e-05 8.21621e-05 6969.34 9.81469e-05 5.78954e-05 3.25402e-05 6.46545e-05 6974.61 3.69222e-05 8.43875e-05 1.53869e-05 7.07399e-06 6979.88 -2.03318e-05 4.72985e-05 1.4187e-05 -4.05251e-06 6985.15 3.88337e-05 8.03578e-06 3.69789e-06 3.77019e-05 6990.43 0.000103934 5.32238e-05 3.52815e-05 3.80681e-05 6995.7 3.42232e-05 5.43098e-05 5.59418e-05 4.14772e-05