CRIRES Calibration Standard Stars Ralf Siebenmorgen 24-07-03 Huges Sana 23-08-07 Florian Rodler 17-01-2025 Band: M (only) From: Hipparcos Main Catalogue Limits: Dec < +30deg, Stars G0 or ealier with V < 4.8mag according to CRIRES sensitivity estimates (Moorwood et al., SPIE2002) *: According to SIMBAD ------------------------------------------------------------------------------------------------------------ Full _RAJ2000 _DEJ2000 HIP Vmag B-V Bmag Vmag Jmag Hmag Kmag SpType* "h:m:s" "d:m:s" mag mag mag* mag* mag* mag* mag* ------------------------------------------------------------------------------------------------------------ 1 00 03 44.390 -17 20 09.56 301 4.55 -0.047 4.503 4.543 4.151 4.610 4.564 B9IVn 2 00 08 23.259 +29 05 25.56 677 2.07 -0.038 1.950 2.060 2.129 2.287 2.223 B8IVmnp... 3 00 20 04.260 -64 52 29.25 1599 4.23 0.576 4.810 4.200 -99.999 -99.999 -99.999 F9V 4 00 26 12.202 -43 40 47.39 2072 3.93 0.175 4.110 3.900 3.739 3.585 3.590 A7V 5 00 31 24.981 -48 48 12.65 2472 4.76 0.018 4.790 4.770 4.668 4.771 4.700 A0V 6 00 31 32.667 -62 57 29.58 2484 4.36 -0.064 4.290 4.335 -99.999 -99.999 -99.999 B9V 7 00 31 33.468 -62 57 56.02 2487 4.53 0.147 4.649 4.514 -99.999 -99.999 -99.999 A2V+... 8 00 43 21.238 -57 27 47.02 3405 4.36 0.024 4.362 4.365 4.160 4.354 4.308 A0IV 9 01 15 46.161 -68 52 33.34 5896 4.25 0.480 4.730 4.250 -99.999 -99.999 -99.999 F6IV 10 01 19 27.995 +27 15 50.61 6193 4.74 0.032 4.800 4.752 4.854 4.599 4.536 A3V 11 01 49 35.103 -10 41 11.08 8497 4.66 0.333 4.981 4.664 3.656 3.470 3.872 F3III 12 01 53 04.908 +29 34 43.79 8796 3.42 0.488 3.900 3.410 2.406 2.182 2.274 F6IV 13 01 53 31.814 +19 17 37.87 8832 3.88 -0.047 3.840 3.880 -99.999 -99.999 -99.999 A0 14 01 54 38.409 +20 48 28.93 8903 2.64 0.165 2.770 2.640 2.340 2.351 2.270 A5V 15 01 57 55.717 +23 35 45.82 9153 4.79 0.290 5.047 4.776 -99.999 -99.999 -99.999 F0V 16 01 58 46.194 -61 34 11.49 9236 2.86 0.290 3.140 2.900 2.124 1.927 1.861 F0V 17 02 02 02.820 +02 45 49.53 9487 3.82 0.024 3.840 3.820 -99.999 -99.999 -99.999 A2 18 02 21 44.943 -68 39 33.91 11001 4.08 0.034 4.122 4.081 4.083 3.984 3.957 A3V 19 02 28 09.542 +08 27 36.19 11484 4.30 -0.053 4.242 4.277 4.696 4.563 4.392 B9III 20 02 32 05.228 -15 14 40.84 11783 4.74 0.454 5.151 4.745 3.834 3.525 3.473 F5V 21 02 39 35.361 -68 16 01.01 12394 4.12 -0.061 4.060 4.106 4.443 4.433 4.254 B9V 22 02 39 47.993 -42 53 30.01 12413 4.74 0.061 4.810 4.750 -99.999 -99.999 -99.999 A2V 23 02 43 18.039 +03 14 08.95 12706 3.47 0.093 3.560 3.470 -99.999 -99.999 -99.999 A3V 24 02 44 56.542 +10 06 50.93 12828 4.27 0.311 4.580 4.200 3.658 3.439 3.463 F0IV 25 02 45 06.185 -18 34 21.23 12843 4.47 0.481 4.950 4.500 3.486 3.236 3.249 F5/F6V 26 02 49 59.032 +27 15 37.83 13209 3.61 -0.100 3.515 3.606 3.657 3.803 3.864 B8Vn 27 02 58 15.675 -40 18 16.82 13847 2.88 0.128 3.030 2.900 -99.999 -99.999 -99.999 A4III+... 28 02 59 12.726 +21 20 25.54 13914 4.63 0.048 4.710 4.660 -99.999 -99.999 -99.999 A2V+... 29 03 02 23.500 -23 37 28.10 14146 4.08 0.163 4.256 4.096 3.657 3.539 3.573 A4V 30 03 12 04.528 -28 59 15.43 14879 3.80 0.543 4.360 3.850 -99.999 -99.999 -99.999 F8IV 31 03 27 10.153 +09 43 57.65 16083 3.73 -0.082 3.663 3.727 3.622 3.738 3.779 B9Vn 32 03 29 22.678 -62 56 15.10 16245 4.71 0.410 5.100 4.710 -99.999 -99.999 -99.999 F5IV-V 33 03 30 37.058 -05 04 30.52 16341 4.74 -0.092 4.642 4.727 5.282 4.960 4.886 B9Vs 34 03 36 52.383 +00 24 05.98 16852 4.29 0.575 4.860 4.280 3.194 2.916 2.835 F9IV-V 35 03 45 49.607 +24 22 03.89 17573 3.87 -0.063 3.812 3.871 4.059 4.122 3.986 B8III 36 --- removed due to emission lines 37 03 46 50.888 -23 14 59.00 17651 4.22 0.434 4.650 4.200 3.609 3.393 3.353 F4V 38 --- removed due to emission lines 39 03 48 35.879 -37 37 12.56 17797 4.30 -0.038 4.250 4.260 -99.999 -99.999 -99.999 A1IVs 40 03 49 09.743 +24 03 12.30 17847 3.62 -0.070 3.540 3.620 3.800 3.864 3.879 B8III 41 04 00 40.816 +12 29 25.25 18724 3.41 -0.099 3.310 3.408 3.572 3.650 3.650 B3V+... 42 04 03 09.380 +05 59 21.50 18907 3.91 0.032 3.943 3.898 3.752 3.842 3.783 A1V 43 04 11 51.940 -06 50 15.29 19587 4.04 0.327 4.353 4.040 3.428 3.250 3.214 F2II-III 44 04 15 32.057 +08 53 32.49 19860 4.27 -0.054 4.214 4.280 4.684 4.413 4.433 B3IV 45 04 16 01.586 -51 29 11.93 19893 4.26 0.312 4.550 4.200 3.683 3.469 3.514 F4III 46 04 25 22.165 +22 17 37.95 20635 4.21 0.136 4.353 4.210 4.093 4.064 4.077 A7IV-V 47 04 25 29.384 +17 55 40.48 20648 4.30 0.049 4.366 4.311 4.338 4.381 4.098 A2IV 48 04 26 18.464 +22 48 48.90 20711 4.28 0.263 4.545 4.293 3.859 3.793 3.761 A8Vn 49 04 26 20.741 +15 37 05.75 20713 4.48 0.262 4.727 4.490 4.167 3.954 4.028 F0V 50 04 28 39.741 +15 52 15.18 20894 3.40 0.179 3.595 3.409 2.994 2.997 2.880 A7III 51 04 30 33.633 +16 11 38.45 21029 4.78 0.170 4.952 4.773 4.773 4.677 4.364 A6IV 52 04 33 50.918 +14 50 39.93 21273 4.65 0.255 4.886 4.657 4.311 4.288 4.074 A8V 53 04 33 59.778 -55 02 41.91 21281 3.30 -0.079 3.180 3.256 -99.999 -99.999 -99.999 A0IIIs... 54 04 35 39.260 +10 09 38.84 21402 4.25 0.184 4.418 4.251 3.702 3.883 3.693 A5m 55 04 38 09.462 +12 30 39.02 21589 4.27 0.122 4.399 4.271 4.117 4.078 4.105 A6V 56 04 39 16.502 +15 55 04.72 21683 4.67 0.147 4.832 4.675 4.682 4.547 4.229 A5Vn 57 04 40 33.713 -41 51 49.51 21770 4.44 0.342 4.759 4.456 -99.999 -99.999 -99.999 F2V 58 04 49 50.411 +06 57 40.59 22449 3.19 0.484 3.640 3.190 1.984 1.757 1.600 F6V 59 04 50 36.722 +08 54 00.63 22509 4.35 0.010 4.372 4.353 3.825 4.208 4.166 A1Vn 60 04 52 53.670 -05 27 09.70 22701 4.36 0.257 4.640 4.400 3.965 3.686 3.724 F4III+... 61 04 54 53.728 +10 09 03.00 22845 4.64 0.085 4.737 4.656 4.846 4.517 4.416 A0V 62 04 59 55.737 -12 32 14.70 23231 4.78 0.267 5.033 4.782 4.035 4.132 4.005 F0V 63 05 03 05.747 +21 35 23.86 23497 4.62 0.155 4.781 4.626 -99.999 -99.999 -99.999 A7V 64 05 04 34.150 +15 24 14.78 23607 4.65 -0.064 4.613 4.663 -99.999 -99.999 4.738 A0sp... 65 05 05 30.656 -57 28 21.73 23693 4.71 0.526 5.193 4.720 3.701 3.407 3.371 F7V 66 05 07 50.985 -05 05 11.21 23875 2.78 0.161 2.920 2.790 2.470 2.439 2.397 A3III 67 05 12 17.902 -11 52 09.19 24244 4.45 -0.099 4.366 4.457 -99.999 -99.999 -99.999 B8V 68 05 13 13.878 -12 56 28.65 24327 4.36 -0.094 4.327 4.421 4.418 4.590 4.556 B7V 69 05 14 32.272 -08 12 05.91 24436 0.18 -0.030 0.090 0.120 0.206 0.176 0.213 B8Iab: 70 05 20 26.918 -21 14 23.15 24927 4.70 -0.048 4.684 4.729 4.268 4.837 4.753 A0V 71 05 32 43.816 -17 49 20.24 25985 2.58 0.211 2.817 2.597 2.030 1.857 1.756 F0Ib 72 05 38 53.083 -07 12 46.18 26563 4.77 0.139 4.930 4.800 4.694 4.545 4.420 A4V 73 --- removed due to emission lines 74 05 44 27.790 -22 26 54.18 27072 3.59 0.481 4.070 3.600 -99.999 -99.999 2.420 F7V 75 05 44 46.379 -65 44 07.89 27100 4.34 0.217 4.560 4.350 4.051 3.813 3.840 A7V 76 05 46 57.341 -14 49 19.02 27288 3.55 0.104 3.655 3.545 3.390 3.314 3.286 A2Vann 77 05 47 17.088 -51 03 59.45 27321 3.85 0.171 4.029 3.861 -99.999 -99.999 -99.999 A5V 78 05 53 19.646 +27 36 44.14 27830 4.56 -0.008 4.549 4.557 4.789 4.734 4.487 A0V 79 05 56 24.293 -14 10 03.72 28103 3.71 0.337 4.022 3.719 3.063 2.985 2.993 F1V 80 06 02 22.999 +09 38 50.20 28614 4.12 0.170 4.290 4.130 -99.999 -99.999 -99.999 A2V 81 --- removed due to strong emission lines 82 06 06 09.324 -14 56 06.92 28910 4.67 0.046 4.714 4.669 4.743 4.593 4.523 A0V 83 06 23 46.085 +04 35 34.31 30419 4.39 0.215 4.593 4.414 -99.999 -99.999 -99.999 A5IV 84 06 23 57.110 -52 41 44.38 30438 -0.62 0.164 -0.570 -0.720 -1.169 -1.280 -1.304 F0II 85 06 32 54.227 +07 19 58.67 31216 4.47 0.023 4.502 4.504 4.531 4.410 4.301 A0Ib 86 06 34 58.580 -52 58 32.19 31407 4.35 -0.021 4.370 4.400 4.302 4.222 4.218 A0II 87 06 35 03.388 -22 57 53.25 31416 4.54 -0.035 4.490 4.500 4.735 4.634 4.498 A0III 88 06 37 42.701 +16 23 57.31 31681 1.93 0.001 1.930 1.900 1.729 1.836 1.917 A0IV 89 06 45 08.917 -16 42 58.02 32349 -1.44 0.009 -1.460 -1.470 -99.999 -99.999 -99.999 A1V 90 06 45 17.365 +12 53 44.13 32362 3.35 0.443 3.790 3.400 1.996 1.811 1.688 F5IV 91 06 48 11.452 -61 56 29.01 32607 3.24 0.225 3.480 3.300 2.766 2.607 2.570 A7IV 92 06 54 38.636 +13 10 40.18 33202 4.73 0.321 4.982 4.706 -99.999 -99.999 -99.999 F0Vp 93 06 55 37.431 -20 08 11.39 33302 4.66 0.374 5.019 4.687 4.144 3.872 3.945 F2IV/V 94 06 56 08.225 -17 03 15.27 33347 4.36 -0.063 4.312 4.385 4.704 4.619 4.540 B3Ib/II 95 07 03 01.473 -23 49 59.85 33977 3.02 -0.077 2.940 3.000 3.334 3.275 3.342 B3Ia 96 07 11 51.860 -00 29 33.95 34769 4.15 -0.005 4.140 4.150 4.038 3.943 3.898 A2V 97 07 12 33.625 -46 45 33.50 34834 4.49 0.324 4.795 4.502 3.500 3.298 3.320 F0IV 98 07 14 38.141 -48 16 18.94 35020 4.75 -0.091 4.667 4.744 4.965 4.981 4.915 B8.5V 99 07 18 05.579 +16 32 25.38 35350 3.58 0.106 3.692 3.581 3.540 3.495 3.535 A3V 100 07 18 18.393 -36 44 02.26 35363 4.65 -0.099 4.580 4.700 4.462 4.666 4.516 B2V+... 101 07 20 07.378 +21 58 56.35 35550 3.50 0.374 3.870 3.530 -99.999 -99.999 -99.999 F0IV 102 07 24 05.703 -29 18 11.17 35904 2.45 -0.083 2.370 2.400 -99.999 -99.999 -99.999 B5Iab: 103 --- removed due to strong emission lines 104 07 34 03.180 -22 17 45.84 36795 4.44 0.521 4.934 4.458 3.703 3.318 3.355 F6V 105 07 37 22.110 -34 58 06.71 37096 4.53 -0.081 4.449 4.525 5.039 4.807 4.754 B8IV 106 07 38 18.046 -25 21 53.30 37173 4.69 -0.100 4.590 4.700 4.873 4.980 4.891 B8IV 107 07 39 18.118 +05 13 29.98 37279 0.40 0.432 0.740 0.340 -0.498 -0.666 -0.658 F5IV-V 108 07 43 48.469 -28 57 17.37 37677 3.94 0.160 4.120 3.978 3.550 3.156 2.463 A3Iab: 109 --- removed due to strong emission lines 110 07 57 40.106 -30 20 04.45 38901 4.76 0.151 4.927 4.789 4.706 4.479 4.218 A2Vv 111 07 59 52.051 -18 23 57.22 39095 4.61 0.087 4.698 4.613 4.579 4.357 4.309 A1V 112 08 07 32.649 -24 18 15.57 39757 2.83 0.458 3.240 2.810 2.171 2.084 2.022 F6IIp... 113 08 09 00.670 -61 18 08.75 39903 4.74 0.437 5.190 4.760 3.909 3.621 3.675 F5V 114 08 11 25.893 -42 59 14.20 40096 4.73 0.164 4.912 4.760 -99.999 -99.999 -99.999 A5Ib 115 08 12 12.726 +17 38 51.97 40167 4.67 0.531 5.200 4.670 -99.999 -99.999 -99.999 G0V 116 08 18 31.550 -76 55 11.00 40702 4.05 0.413 4.436 4.066 3.415 3.147 3.150 F5III 117 08 18 33.312 -36 39 33.44 40706 4.44 0.222 4.657 4.448 4.207 4.087 4.063 A7III 118 08 25 39.632 -03 54 23.13 41307 3.91 -0.012 3.880 3.900 4.117 4.090 4.079 A0V 119 08 37 38.633 -42 59 20.69 42312 4.11 0.109 4.245 4.141 3.848 3.659 3.703 A6II 120 08 37 39.366 +05 42 13.61 42313 4.14 0.003 4.157 4.137 4.147 4.126 4.033 A1Vnn 121 08 41 13.131 -47 19 01.65 42624 4.74 0.137 4.888 4.773 4.343 4.170 4.129 A5II 122 08 43 17.146 +21 28 06.60 42806 4.66 0.010 4.690 4.668 4.799 4.788 4.638 A1IV 123 08 44 42.226 -54 42 31.76 42913 1.93 0.043 2.000 1.950 1.777 1.762 1.719 A1V 124 08 46 01.644 -46 02 29.50 43023 3.87 0.015 3.906 3.894 3.682 3.554 3.626 A1III 125 08 48 25.971 +05 50 16.12 43234 4.35 -0.044 4.327 4.343 4.496 4.508 4.360 A0Vn 126 08 58 29.222 +11 51 27.72 44066 4.26 0.141 4.401 4.259 -99.999 -99.999 -99.999 A5m 127 09 02 26.796 -66 23 45.88 44382 4.00 0.145 4.155 4.004 3.911 3.741 3.883 A2.5IVm 128 09 13 11.975 -69 43 01.95 45238 1.67 0.070 1.680 1.700 1.493 1.500 1.487 A2IV 129 09 14 21.859 +02 18 51.41 45336 3.89 -0.060 3.820 3.880 3.455 4.040 3.943 B9.5V 130 09 15 45.080 -37 24 47.32 45448 4.63 0.473 5.054 4.638 -99.999 -99.999 -99.999 F5III 131 09 17 05.407 -59 16 30.83 45556 2.21 0.189 2.437 2.249 1.667 1.573 1.525 A8Ib 132 09 29 08.898 -02 46 08.27 46509 4.59 0.411 5.060 4.600 -99.999 -99.999 -99.999 F6V 133 09 30 42.000 -40 28 00.37 46651 3.60 0.371 3.914 3.590 -99.999 -99.999 -99.999 F3IV+... 134 09 31 58.928 -01 11 04.79 46776 4.54 0.109 4.659 4.555 4.315 4.187 4.146 A3V 135 09 34 26.650 -59 13 47.11 46974 4.08 -0.013 4.076 4.092 4.224 4.127 4.140 B5II 136 09 36 49.540 -49 21 18.09 47175 4.34 0.173 4.512 4.345 4.129 3.985 3.938 A5IV-V 137 09 39 20.999 -61 19 41.02 47391 4.51 -0.070 4.454 4.508 4.982 4.816 4.647 B9IV-V 138 09 41 09.033 +09 53 32.31 47508 3.52 0.516 3.993 3.531 2.765 2.603 2.503 A5V+... 139 09 44 12.095 -27 46 10.10 47758 4.78 0.516 6.000 5.500 -99.999 -99.999 -99.999 F7V 140 09 47 06.122 -65 04 19.22 48002 2.92 0.273 3.240 2.960 -99.999 -99.999 -99.999 A9 141 09 56 51.742 -54 34 04.05 48774 3.52 -0.067 3.460 3.500 3.742 3.696 3.729 B5Ib 142 10 05 07.470 -13 03 52.65 49402 4.60 -0.087 4.515 4.594 4.681 4.774 4.727 B8V 143 10 07 19.952 +16 45 45.59 49583 3.48 -0.031 3.484 3.511 3.499 3.499 3.299 A0Ib 144 10 07 56.280 -00 22 17.89 49641 4.48 -0.032 4.450 4.490 4.654 4.596 4.454 A0III 145 10 08 22.311 +11 58 01.95 49669 1.36 -0.087 1.240 1.350 1.665 1.658 1.640 B7V 146 --- removed due to strong emission lines 147 10 14 44.155 -42 07 18.99 50191 3.85 0.051 3.903 3.840 -99.999 -99.999 -99.999 A2V 148 10 16 41.417 +23 25 02.32 50335 3.43 0.307 3.733 3.443 2.700 2.628 2.631 F0III 149 10 19 44.168 +19 28 15.29 50564 4.78 0.452 5.240 4.800 4.037 3.944 4.020 F6IV 150 10 24 23.706 -74 01 53.80 50954 3.99 0.369 4.324 3.995 3.473 3.235 3.252 F2IV 151 10 27 24.471 -57 38 19.70 51192 4.65 0.474 5.170 4.660 3.518 3.207 3.108 A9Ia 152 10 27 52.730 -58 44 21.85 51232 3.81 0.317 4.110 3.828 3.095 2.957 2.910 F2II 153 10 30 20.128 -71 59 34.05 51438 4.72 0.042 4.765 4.718 4.747 4.715 4.565 A1V 154 --- removed due to strong emission lines 155 10 37 18.142 -48 13 32.23 51986 3.84 0.300 4.140 3.840 -99.999 -99.999 -99.999 A3m+... 156 10 55 36.798 +24 44 58.99 53417 4.30 0.016 4.340 4.320 -99.999 -99.999 -99.999 A1 157 11 00 09.264 -42 13 33.09 53773 4.37 0.116 4.489 4.377 4.247 4.105 4.071 A3IV 158 11 02 19.775 +20 10 47.43 53954 4.42 0.053 4.465 4.407 4.315 4.324 4.315 A1m 159 11 05 01.027 +07 20 09.63 54182 4.62 0.332 4.960 4.630 4.038 3.769 3.741 F2III-IVv 160 11 11 39.489 -22 49 33.05 54682 4.46 0.025 4.493 4.461 4.324 4.415 4.337 A1V 161 --- removed due to strong emission lines 162 11 14 06.501 +20 31 25.38 54872 2.56 0.128 2.680 2.560 2.238 2.191 2.144 A4V 163 11 14 14.405 +15 25 46.45 54879 3.33 -0.003 3.337 3.324 3.115 3.190 3.082 A2V 164 11 16 39.701 -03 39 05.76 55084 4.45 0.210 4.665 4.467 -99.999 -99.999 -99.999 A7IVn 165 11 21 08.194 +06 01 45.56 55434 4.05 -0.058 3.996 4.044 4.366 4.325 4.139 B9.5Vs 166 11 23 55.452 +10 31 46.23 55642 4.00 0.423 4.350 4.000 -99.999 -99.999 -99.999 F4IV 167 11 24 52.924 -17 41 02.43 55705 4.06 0.216 4.290 4.080 -99.999 -99.999 -99.999 A9V 168 --- removed due to strong emission lines 169 11 35 46.885 -63 01 11.43 56561 3.11 -0.044 3.081 3.117 3.091 3.047 3.066 B9III 170 11 36 40.913 -09 48 08.09 56633 4.70 -0.073 4.626 4.682 4.788 4.845 4.778 B9.5Vn 171 11 40 12.789 -34 44 40.78 56922 4.70 -0.070 4.623 4.693 4.822 4.948 4.791 B9V 172 11 45 36.419 -66 43 43.55 57363 3.63 0.160 3.796 3.634 -99.999 -99.999 -99.999 A7III 173 11 47 59.136 +20 13 08.15 57565 4.50 0.547 5.053 4.537 3.258 2.935 2.824 A7V+... 174 11 49 03.578 +14 34 19.42 57632 2.14 0.090 2.230 2.140 -99.999 -99.999 -99.999 A3V 175 11 50 41.719 +01 45 52.98 57757 3.59 0.518 4.160 3.610 2.597 2.363 2.269 F9V 176 11 52 54.521 -33 54 29.25 57936 4.29 -0.100 4.193 4.276 4.617 4.557 4.431 B9IIIsp... 177 12 00 52.390 +06 36 51.56 58590 4.65 0.122 4.775 4.659 4.772 4.542 4.250 A5V 178 12 03 01.501 -63 18 46.55 58758 4.32 0.280 4.600 4.300 3.504 3.260 3.231 Am 179 12 04 19.216 -63 09 56.56 58867 4.72 -0.081 4.626 4.718 4.900 4.969 4.939 B2IV 180 12 06 52.899 -64 36 49.43 59072 4.14 0.353 4.462 4.145 3.446 3.229 3.197 F2III 181 12 08 24.817 -24 43 43.95 59199 4.02 0.334 4.340 4.000 3.525 3.364 3.307 F0IV/V 182 12 19 54.357 -00 40 00.49 60129 3.89 0.026 3.930 3.890 -99.999 -99.999 -99.999 A2IV 183 12 22 30.312 +25 50 46.18 60351 4.78 0.515 5.300 -99.999 3.781 3.401 3.236 F2 184 12 29 51.855 -16 30 55.56 60965 2.94 -0.012 2.900 2.950 2.934 3.000 3.003 B9.5V 185 12 32 04.227 -16 11 45.63 61174 4.30 0.388 4.690 4.310 3.609 3.372 3.372 F2V 186 12 37 42.163 -48 32 28.69 61622 3.85 0.049 3.907 3.852 3.798 3.682 3.713 A2V 187 12 39 52.529 -39 59 14.29 61789 4.63 -0.082 4.548 4.627 4.880 4.903 4.785 B8II/III 188 12 41 31.039 -48 57 35.60 61932 2.20 -0.023 2.200 2.180 2.051 2.180 2.100 A1IV 189 12 41 39.642 -01 26 57.75 61941 2.74 0.368 3.900 3.560 -99.999 -99.999 -99.999 F0V 190 12 53 26.199 -40 10 43.94 62896 4.25 0.224 4.467 4.268 3.915 3.683 3.714 A7III 191 13 09 56.991 -05 32 20.43 64238 4.38 -0.008 4.381 4.381 -99.999 -99.999 -99.999 A1IVs+... 192 13 09 59.277 +17 31 45.95 64241 4.32 0.455 4.770 4.320 -99.999 -99.999 -99.999 F5V 193 13 11 52.393 +27 52 41.46 64394 4.23 0.572 4.830 4.260 3.232 2.992 2.923 G0V 194 13 12 17.596 -59 55 14.08 64425 4.58 -0.073 4.505 4.583 -99.999 -99.999 -99.999 B8V 195 13 15 14.941 -67 53 40.52 64661 4.79 -0.078 4.697 4.774 4.949 5.031 4.991 B8V 196 13 20 35.818 -36 42 44.26 65109 2.75 0.068 2.790 2.700 2.714 2.738 2.757 A2V 197 13 34 41.592 -00 35 44.95 66249 3.38 0.114 3.480 3.400 3.257 3.154 3.223 A3V 198 13 45 41.245 -33 02 37.40 67153 4.23 0.390 4.610 4.230 3.585 3.347 3.410 F3IV 199 13 47 15.743 +17 27 24.86 67275 4.50 0.508 4.980 4.500 -99.999 -99.999 3.507 F6IV 200 13 54 41.079 +18 23 51.78 67927 2.68 0.580 3.260 2.680 1.793 1.534 1.485 G0IV 201 14 01 38.793 +01 32 40.31 68520 4.23 0.121 4.341 4.244 4.212 4.107 4.091 A3V 202 14 16 00.870 -06 00 01.97 69701 4.07 0.511 4.600 4.100 3.140 2.909 2.801 F7IV 203 14 19 06.592 -13 22 15.94 69974 4.52 0.128 4.653 4.523 4.395 4.282 4.241 A1V 204 14 20 19.543 -56 23 11.39 70069 4.30 0.082 4.419 4.349 4.238 4.154 3.904 B6Ib 205 14 20 33.432 -37 53 07.06 70090 4.05 -0.030 4.022 4.049 -99.999 -99.999 -99.999 A0IV 206 14 20 42.582 -45 11 13.42 70104 4.78 0.310 5.057 4.779 4.245 3.975 4.080 F0IV 207 14 26 10.813 -45 22 45.39 70576 4.33 0.434 4.747 4.357 3.366 2.985 2.933 F7 208 14 34 40.817 +29 44 42.47 71284 4.47 0.364 4.820 4.460 3.561 3.462 3.336 F2V 209 14 40 43.567 +16 25 05.97 71762 4.49 -0.002 4.910 4.910 -99.999 -99.999 -99.999 B9p 210 14 41 08.952 +13 43 41.88 71795 3.78 0.044 3.848 3.793 3.738 3.747 3.697 A3IVn 211 14 42 30.419 -64 58 30.50 71908 3.18 0.256 3.430 3.190 -99.999 -99.999 -99.999 Ap... 212 14 43 03.623 -05 39 29.54 71957 3.87 0.385 4.260 3.900 3.335 3.069 3.039 F2III 213 14 46 14.924 +01 53 34.39 72220 3.73 -0.005 3.710 3.720 3.683 3.628 3.646 A0V 214 14 50 52.713 -16 02 30.40 72622 2.75 0.147 2.912 2.753 2.467 2.439 2.440 A3IV 215 14 57 11.000 -04 20 47.26 73165 4.47 0.318 4.768 4.476 4.125 3.824 3.914 F0V 216 --- removed due to strong emission lines 217 15 12 13.290 -19 47 30.16 74392 4.54 -0.071 4.460 4.540 -99.999 -99.999 -99.999 B9Vp 218 15 17 00.415 -09 22 58.50 74785 2.61 -0.071 2.535 2.605 2.761 2.894 2.905 B8V 219 15 17 30.849 -58 48 04.35 74824 4.07 0.088 4.169 4.069 3.928 3.806 3.875 A3V 220 --- removed due to strong emission lines 221 15 18 54.582 -68 40 46.36 74946 2.87 0.014 2.908 2.881 2.524 2.527 2.531 A1V 222 15 23 22.646 -59 19 14.83 75323 4.48 0.169 4.700 4.510 -99.999 -99.999 -99.999 B5IV+... 223 15 25 20.218 -38 44 01.03 75501 4.60 -99.999 4.600 4.600 4.446 4.353 4.483 A0IV 224 15 27 49.731 +29 06 20.53 75695 3.66 0.319 3.960 3.680 3.598 3.553 3.456 F0p 225 15 34 41.268 +26 42 52.89 76267 2.22 0.032 2.244 2.214 -99.999 -99.999 -99.999 A0V 226 15 34 48.147 +10 32 19.92 76276 3.80 0.268 4.050 3.790 -99.999 -99.999 -99.999 F0 227 15 41 11.377 -44 39 40.34 76829 4.64 0.413 5.040 4.640 4.023 3.732 3.802 F5IV-V 228 15 41 33.055 +19 40 13.44 76852 4.51 0.062 4.567 4.509 -99.999 -99.999 -99.999 A1V 229 15 42 44.565 +26 17 44.29 76952 3.81 0.020 3.840 3.840 3.620 3.691 3.670 B9IV+... 230 15 46 11.256 +15 25 18.57 77233 3.65 0.073 3.733 3.660 -99.999 -99.999 -99.999 A3V 231 15 49 37.208 -03 25 48.75 77516 3.54 -0.036 3.529 3.548 3.799 3.759 3.702 A0V 232 15 50 48.966 +04 28 39.83 77622 3.71 0.147 3.859 3.713 3.564 3.440 3.425 A2m 233 15 50 57.538 -33 37 37.80 77634 3.97 -0.045 3.926 3.957 -99.999 -99.999 -99.999 B9IV 234 15 50 58.745 -25 45 04.66 77635 4.63 -0.072 4.566 4.638 4.802 4.860 4.783 B1.5Vn 235 15 53 36.719 -25 19 37.71 77840 4.59 -0.073 4.520 4.590 4.740 4.814 4.789 B2.5Vn 236 15 55 08.562 -63 25 50.62 77952 2.83 0.315 3.140 2.850 -99.999 -99.999 -99.999 F2III 237 15 56 27.183 +15 39 41.82 78072 3.85 0.478 4.330 3.850 3.149 2.875 2.703 F6IV 238 16 03 32.092 -57 46 30.23 78662 4.63 0.252 4.870 4.630 -99.999 -99.999 -99.999 A7IV 239 16 05 26.231 -19 48 19.63 78820 2.56 -0.065 2.550 2.620 -99.999 -99.999 -99.999 B0.5V 240 16 06 29.438 -45 10 23.47 78914 4.73 0.230 4.954 4.726 4.519 4.285 4.267 Am 241 16 06 48.426 -20 40 09.09 78933 3.93 -0.046 3.900 3.946 4.160 4.188 4.009 B1V 242 16 11 59.735 -19 27 38.55 79374 4.00 0.076 4.110 4.130 3.970 3.795 3.878 B2IV 243 16 21 11.316 -25 35 34.07 80112 2.90 0.299 3.009 2.912 -99.999 -99.999 -99.999 B1III 244 16 21 55.214 +19 09 11.27 80170 3.74 0.299 4.009 3.742 3.269 3.118 2.944 A9III 245 16 25 24.953 +14 01 59.77 80463 4.57 0.002 4.587 4.574 -99.999 -99.999 -99.999 B9p... 246 16 25 35.118 -23 26 49.84 80473 4.57 0.227 4.850 4.630 -99.999 -99.999 -99.999 BIV+... 247 --- removed due to strong emission lines 248 16 27 11.036 -47 33 17.23 80582 4.46 -0.070 4.451 4.525 -99.999 -99.999 -99.999 B4V 249 16 27 48.187 -08 22 18.23 80628 4.62 0.185 4.800 4.630 -99.999 -99.999 -99.999 A3m 250 16 30 54.823 +01 59 02.12 80883 3.82 0.022 3.940 3.900 -99.999 -99.999 -99.999 A0V+... 251 16 32 08.199 -21 27 59.00 80975 4.45 0.130 4.576 4.443 3.922 3.849 4.137 A7p 252 16 37 09.538 -10 34 01.52 81377 2.54 0.038 2.595 2.578 2.533 2.667 2.684 O9V 253 16 49 50.029 -10 46 58.80 82369 4.64 0.478 5.090 4.646 3.836 3.581 3.561 F7IV 254 --- removed due to strong emission lines 255 16 54 00.472 +10 09 55.29 82673 4.39 -0.088 4.300 4.380 4.761 4.624 4.561 B8V 256 17 10 22.687 -15 43 29.68 84012 2.43 0.059 2.490 2.430 2.369 2.409 2.336 A2.5Va 257 17 12 09.194 -43 14 21.08 84143 3.32 0.441 3.740 3.330 2.398 2.295 2.255 F3III-IVp 258 17 15 01.911 +24 50 21.13 84379 3.12 0.080 3.217 3.126 2.834 2.976 2.808 A3IV 259 17 20 49.661 -12 50 48.75 84880 4.32 0.037 4.380 4.336 4.128 4.034 4.188 A0/A1V 260 17 21 00.374 -21 06 46.56 84893 4.39 0.394 4.780 4.390 3.355 3.136 3.067 F2/F3V 261 17 26 22.216 -24 10 31.11 85340 4.16 0.283 4.437 4.166 3.489 3.335 3.338 A3m... 262 17 26 37.881 -05 05 11.74 85365 4.53 0.385 4.930 4.500 -99.999 -99.999 -99.999 F3V 263 17 27 21.274 -29 52 01.32 85423 4.28 0.402 4.660 4.286 3.413 3.206 3.203 F5IVs... 264 17 31 24.954 -23 57 45.52 85755 4.78 0.016 4.810 4.810 4.900 4.712 4.296 A0V 265 17 34 56.071 +12 33 36.13 86032 2.08 0.155 2.230 2.100 1.833 1.718 1.683 A5III 266 17 35 39.590 -46 30 20.46 86092 4.56 -0.020 4.552 4.571 4.745 4.658 4.472 A0V 267 17 37 19.131 -42 59 52.17 86228 1.86 0.406 2.261 1.862 1.074 0.865 0.841 F1II 268 17 37 35.201 -15 23 54.81 86263 3.54 0.262 3.795 3.539 3.065 2.913 2.911 F0IIIp 269 17 37 50.713 -08 07 07.57 86284 4.58 0.132 4.712 4.618 4.420 4.240 4.250 B8II-IIImnp... 270 17 40 23.826 -49 24 56.11 86486 4.76 0.415 5.170 4.770 -99.999 -99.999 -99.999 F3IV 271 17 41 24.873 -12 52 31.10 86565 4.24 0.086 4.331 4.244 4.248 4.181 4.107 A2Va 272 17 47 35.081 -40 07 37.19 87073 2.99 0.509 3.485 3.020 1.881 1.766 1.690 F2Iae 273 17 47 53.561 +02 42 26.19 87108 3.75 0.043 3.790 3.750 -99.999 -99.999 -99.999 A0V 274 17 49 10.476 -31 42 11.53 87220 4.79 -0.028 4.764 4.806 4.482 4.786 4.753 B8V 275 17 50 11.113 -40 05 25.57 87294 4.78 0.259 5.035 4.814 -99.999 -99.999 -99.999 A2Ib 276 17 59 47.553 -23 48 58.08 88116 4.74 -0.030 4.709 4.731 4.843 4.607 4.469 B9V 277 1--- removed due to strong emission lines 278 18 00 29.011 -03 41 24.97 88175 4.62 0.390 4.990 4.633 -99.999 -99.999 -99.999 F2IV 279 18 00 38.716 +02 55 53.64 88192 3.93 0.029 3.972 3.974 -99.999 -99.999 -99.999 B5Ib 280 18 01 30.408 +21 35 44.82 88267 4.26 0.406 5.080 4.960 -99.999 -99.999 2.540 A5IIIn 281 18 01 45.199 +01 18 18.27 88290 4.42 0.046 4.473 4.439 4.637 4.519 4.233 A2Vn 282 18 03 04.920 -08 10 49.26 88404 4.77 0.410 5.170 4.780 -99.999 -99.999 -99.999 F3IV 283 18 07 20.984 +09 33 49.85 88771 3.71 0.159 3.863 3.722 -99.999 -99.999 -99.999 A4IVs 284 18 07 32.551 +28 45 44.96 88794 3.84 -0.018 3.821 3.837 3.968 3.960 3.954 B9.5V 285 18 08 34.814 -63 40 06.79 88866 4.33 0.228 4.564 4.333 3.978 3.804 3.804 A7sp... 286 18 13 45.810 -21 03 31.80 89341 3.84 0.195 4.014 3.841 3.272 3.178 3.078 B2III: 287 18 24 10.318 -34 23 04.62 90185 1.79 -0.031 1.820 1.800 -99.999 -99.999 -99.999 B9.5III 288 18 29 11.854 -14 33 56.93 90595 4.67 0.076 4.755 4.686 4.803 4.622 4.360 A1IV/V 289 18 42 16.427 -09 03 09.18 91726 4.70 0.358 5.040 4.710 4.224 3.978 3.950 F2IIIp 290 18 45 26.901 -64 52 16.53 92024 4.78 0.199 4.970 4.779 4.382 4.251 4.298 A5IV-V 291 18 45 39.725 +20 32 46.71 92043 4.19 0.483 4.650 4.200 3.527 3.286 3.190 F6V 292 18 47 01.274 +18 10 53.47 92161 4.34 0.148 4.477 4.346 4.498 4.447 4.079 A5III 293 18 56 13.182 +04 12 12.94 92946 4.62 0.161 4.790 4.620 4.160 4.163 4.085 A5V 294 18 56 57.029 -67 14 00.58 93015 4.40 0.530 5.080 4.400 3.343 2.906 2.716 F5Ib-II: 295 19 02 36.714 -29 52 48.38 93506 2.60 0.062 2.704 2.607 2.319 2.318 2.293 A2III+... 296 19 03 06.876 -42 05 42.38 93542 4.74 -0.027 4.716 4.734 4.717 4.960 4.753 B9.5V 297 19 05 24.608 +13 51 48.52 93747 2.99 0.014 3.016 2.988 -99.999 -99.999 -99.999 A0Vn 298 19 06 14.938 -04 52 57.20 93805 3.43 -0.096 3.351 3.427 3.522 3.477 3.564 B9Vn 299 19 06 25.110 -37 03 48.37 93825 4.23 0.523 4.720 4.200 -99.999 -99.999 -99.999 F7IV-V 300 19 09 28.342 -37 54 16.11 94114 4.11 0.042 4.165 4.102 4.094 3.915 4.049 A2V 301 19 09 45.833 -21 01 25.01 94141 2.88 0.377 3.240 2.890 2.027 1.896 1.860 F2II/III 302 19 16 13.040 +21 23 25.54 94703 4.76 -0.058 4.688 4.758 4.824 4.931 4.906 B4IV 303 19 21 40.359 -17 50 49.91 95168 3.92 0.228 4.149 3.937 3.608 3.412 3.409 F0III/IV 304 19 21 43.623 -15 57 18.06 95176 4.52 0.079 4.643 4.578 4.153 3.385 2.624 F2p 305 19 22 38.292 -44 27 32.27 95241 3.96 -0.085 3.869 3.954 -99.999 -99.999 -99.999 B9V 306 19 23 13.137 -44 47 59.20 95294 4.27 0.350 4.594 4.281 3.183 2.935 2.931 F2III 307 19 25 29.900 +03 06 53.19 95501 3.36 0.319 3.680 3.400 2.636 2.475 2.443 F0IV 308 19 26 31.089 +00 20 18.85 95585 4.64 0.576 5.209 4.687 -99.999 -99.999 -99.999 F2Iab: 309 19 36 42.433 -24 53 01.04 96465 4.59 -0.075 4.537 4.598 -99.999 -99.999 -99.999 B8/B9V 310 19 36 43.278 -01 17 11.76 96468 4.36 -0.079 4.270 4.349 4.444 4.422 4.482 B5III 311 19 50 46.999 +08 52 05.96 97649 0.76 0.221 0.990 0.770 0.313 0.102 0.102 A7V 312 19 53 27.695 +24 04 46.61 97886 4.57 -0.047 4.520 4.580 4.479 -99.999 4.584 B9.5III 313 20 00 35.553 -72 54 37.81 98495 3.97 -0.032 3.944 3.950 3.798 3.762 3.800 A0V 314 20 01 06.048 +27 45 12.86 98543 4.66 0.184 4.837 4.663 4.555 4.437 4.179 A4III 315 20 11 18.285 -00 49 17.26 99473 3.24 -0.066 3.197 3.242 -99.999 -99.999 -99.999 B9.5III 316 20 20 39.816 -12 45 32.69 100310 4.77 -0.047 4.716 4.754 4.909 4.856 4.807 B9IV 317 20 28 51.614 -17 48 49.27 101027 4.77 0.386 5.137 4.803 -99.999 -99.999 -99.999 F3V 318 20 35 18.535 +14 40 27.17 101589 4.64 0.120 4.768 4.664 4.821 4.484 4.357 A3V 319 20 35 34.851 -60 34 54.30 101612 4.75 0.291 5.031 4.759 4.280 4.016 4.044 F1III 320 20 37 32.941 +14 35 42.31 101769 3.64 0.425 4.044 3.632 2.866 2.760 2.643 F5IV 321 20 39 38.287 +15 54 43.46 101958 3.77 -0.057 3.726 3.771 -99.999 -99.999 -99.999 B9IV 322 20 43 27.534 +15 04 28.49 102281 4.43 0.302 4.707 4.434 3.898 3.745 3.831 A7IIIp... 323 20 44 02.334 -51 55 15.50 102333 4.51 0.278 4.776 4.519 3.909 3.692 3.820 A7III-IVv... 324 20 44 57.494 -66 12 11.57 102395 3.42 0.163 3.590 3.426 2.934 2.794 2.799 A7III 325 20 46 05.733 -25 16 15.23 102485 4.13 0.426 4.545 4.152 3.363 3.104 3.094 F5V 326 20 47 40.551 -09 29 44.79 102618 3.78 -99.999 3.783 3.770 3.848 3.671 3.737 A1.5V 327 20 52 39.234 -08 58 59.94 103045 4.73 0.325 5.029 4.723 4.287 4.077 3.962 A3m 328 21 05 56.828 -17 13 58.30 104139 4.08 -0.010 4.089 4.073 4.372 4.316 4.100 A1V 329 21 10 20.500 +10 07 53.69 104521 4.70 0.262 4.983 4.712 4.277 4.105 4.009 A9p 330 21 14 28.815 +10 00 25.13 104858 4.47 0.529 4.990 4.490 -99.999 -99.999 -99.999 F5V+... 331 21 15 49.432 +05 14 52.24 104987 3.92 0.549 4.449 3.949 2.809 2.442 2.343 G0III+... 332 21 17 56.285 -32 10 21.14 105140 4.71 0.070 4.794 4.721 4.622 4.630 4.493 A1V 333 21 19 51.989 -53 26 57.94 105319 4.39 0.191 4.580 4.400 -99.999 -99.999 -99.999 A5V 334 21 26 26.606 -65 21 58.31 105858 4.21 0.494 4.710 4.220 3.340 2.992 2.969 F6V 335 21 37 45.109 -07 51 15.13 106786 4.68 0.175 4.859 4.690 4.359 4.219 4.252 A7V 336 21 40 05.456 -16 39 44.31 106985 3.69 0.320 4.000 3.680 3.289 3.066 3.065 A7mp... 337 21 44 08.578 +28 44 33.48 107310 4.49 0.512 4.970 4.500 -99.999 -99.999 -99.999 F6V 338 21 44 38.734 +25 38 42.13 107354 4.14 0.425 4.550 4.159 -99.999 -99.999 -99.999 F5IV 339 21 44 56.810 -33 01 32.81 107380 4.35 -0.053 4.303 4.335 4.289 4.596 4.424 A0V 340 21 47 02.445 -16 07 38.23 107556 2.85 0.180 3.160 2.870 2.254 2.063 2.014 A7IIIm 341 21 53 55.724 -37 21 53.47 108085 3.00 -0.084 2.890 3.010 3.051 3.027 3.098 B8III 342 21 57 55.075 -54 59 33.27 108431 4.40 0.297 4.680 4.400 3.597 3.415 3.416 F0IV 343 --- removed due to strong emission lines 344 22 06 26.230 -13 52 10.84 109139 4.29 -0.075 4.219 4.281 -99.999 -99.999 -99.999 B8V 345 22 07 00.666 +25 20 42.40 109176 3.77 0.435 4.200 3.760 -99.999 -99.999 -99.999 F5V 346 22 08 13.985 -46 57 39.51 109268 1.73 -0.070 1.610 1.740 2.021 2.027 2.016 B7IV 347 22 08 23.009 -32 59 18.49 109285 4.50 0.054 4.558 4.497 4.455 4.550 4.309 A2V 348 22 10 11.985 +06 11 52.31 109427 3.52 0.086 3.610 3.500 3.455 3.390 3.377 A2V 349 22 21 19.339 +28 19 49.91 110371 4.78 -0.010 4.783 4.806 4.937 4.756 4.734 B9III 350 22 21 39.375 -01 23 14.39 110395 3.86 -0.057 3.815 3.847 4.110 4.053 4.021 A0V 351 22 27 19.968 -64 57 58.88 110838 4.51 -0.029 4.482 4.495 4.384 4.410 4.547 B9.5V 352 22 28 49.912 -00 01 11.90 110960 3.65 0.406 4.060 3.650 -99.999 -99.999 -99.999 F3III-IV 353 22 31 30.331 -32 20 45.86 111188 4.29 0.011 4.309 4.289 4.345 4.297 4.253 A0V 354 22 35 21.381 -00 07 02.99 111497 4.04 -0.083 3.930 4.020 4.276 4.334 4.236 B9IV-Vn 355 22 41 27.721 +10 49 52.91 112029 3.41 -0.086 3.310 3.400 -99.999 -99.999 -99.999 B8V 356 22 46 03.508 -81 22 53.81 112405 4.13 0.208 4.342 4.141 3.768 3.577 3.715 A9IV-V 357 22 46 41.581 +12 10 22.40 112447 4.20 0.502 4.690 4.200 3.358 3.078 2.961 F7V 358 22 48 33.298 -51 19 00.71 112623 3.49 0.083 3.582 3.489 3.180 3.162 3.189 A3V 359 22 52 31.535 -32 52 31.81 112948 4.46 -0.037 4.464 4.501 -99.999 -99.999 -99.999 A0III... 360 22 54 39.013 -15 49 14.95 113136 3.27 0.066 3.344 3.269 3.266 3.201 3.164 A3V 361 22 57 39.046 -29 37 20.05 113368 1.17 0.145 1.250 1.160 -99.999 -99.999 -99.999 A3V 362 23 04 45.654 +15 12 18.95 113963 2.49 -0.002 2.450 2.490 2.535 2.744 2.647 B9III 363 --- removed due to strong emission lines 364 23 17 25.773 -58 14 08.64 114996 3.99 0.410 4.369 4.003 -99.999 -99.999 -99.999 F1III 365 23 20 38.243 +23 44 25.21 115250 4.58 0.180 4.756 4.592 4.331 4.362 4.085 A5V 366 --- removed due to strong emission lines. 367 23 33 16.624 -20 54 52.21 116247 4.70 0.020 4.728 4.709 4.854 4.704 4.522 A0V 368 23 35 04.564 -42 36 54.27 116389 4.69 0.078 4.796 4.711 4.558 4.368 4.465 A2Vp... 369 23 37 50.995 -45 29 32.46 116602 4.74 0.082 4.821 4.736 4.530 4.450 4.520 A2V 370 23 39 57.041 +05 37 34.65 116771 4.13 0.507 4.640 4.130 3.299 2.988 2.946 F7V 371 23 42 02.806 +01 46 48.15 116928 4.49 0.200 4.700 4.500 4.372 4.204 4.064 A7V 372 23 42 43.344 -14 32 41.66 116971 4.49 -0.032 4.451 4.483 -99.999 -99.999 -99.999 B9V 373 23 48 55.546 -28 07 48.96 117452 4.59 0.001 4.586 4.577 4.801 4.643 4.532 A0V 374 23 59 18.690 +06 51 47.96 118268 4.03 0.419 4.410 4.036 3.505 3.298 3.100 F4IV 375 23 59 54.979 -65 34 37.68 118322 4.49 -0.075 4.417 4.490 4.777 4.675 4.601 B9IV 376 00 13 14.153 +15 11 00.95 1067 2.83 -0.190 2.600 2.830 3.500 3.638 3.770 B2IV 377 01 08 23.082 -55 14 44.74 5348 3.94 -0.120 3.879 3.967 4.216 4.215 4.204 B7V 378 --- removed due to strong emission lines 379 02 16 30.585 -51 30 43.79 10602 3.56 -0.120 3.451 3.545 -99.999 -99.999 -99.999 B8IV-V 380 --- removed due to strong emission lines 381 04 17 53.662 -33 47 54.05 20042 3.55 -0.108 3.452 3.546 -99.999 -99.999 -99.999 B9V 382 04 36 19.142 -03 21 08.85 21444 3.93 -0.210 3.739 3.920 4.082 4.581 4.507 B2III 383 04 51 12.364 +05 36 18.37 22549 3.68 -0.157 3.514 3.668 4.111 4.154 4.133 B2III+... 384 04 54 15.096 +02 26 26.42 22797 3.71 -0.179 3.540 3.720 4.189 4.353 4.271 B3III+... 385 05 12 55.901 -16 12 19.69 24305 3.29 -0.110 3.188 3.279 -99.999 -99.999 -99.999 B9IV:... 386 05 17 36.390 -06 50 39.87 24674 3.59 -0.115 3.470 3.590 -99.999 -99.999 -99.999 B5III 387 05 24 28.617 -02 23 49.73 25281 3.35 -0.240 3.210 3.380 3.967 3.997 3.900 B0.5V 388 05 25 07.863 +06 20 58.93 25336 1.64 -0.224 1.420 1.640 -99.999 -99.999 -99.999 B2III 389 05 26 17.513 +28 36 26.82 25428 1.65 -0.130 1.620 1.680 1.855 1.881 2.004 B7III 390 05 32 00.401 -00 17 56.73 25930 2.25 -0.175 2.010 2.230 2.744 2.981 3.023 O9.5II+... 391 05 35 08.277 +09 56 02.97 26207 3.39 -0.160 3.200 3.390 -99.999 -99.999 -99.999 O... 392 05 35 25.982 -05 54 35.64 26241 2.75 -0.210 2.530 2.770 3.490 3.648 3.752 O9III 393 05 36 12.813 -01 12 06.91 26311 1.69 -0.184 1.510 1.700 2.191 2.408 2.273 B0Iab: 394 05 37 38.686 +21 08 33.18 26451 2.97 -0.148 2.840 3.030 3.001 3.047 2.808 B2IV 395 05 38 44.768 -02 36 00.25 26549 3.77 -0.190 3.560 3.800 4.752 4.641 4.490 O9.5V 396 --- removed due to strong emission lines 397 05 40 45.527 -01 56 33.26 26727 1.74 -0.199 1.590 1.790 -99.999 -99.999 -99.999 O9.5Ib 398 05 47 45.389 -09 40 10.58 27366 2.07 -0.168 1.937 2.049 2.469 2.686 2.679 B0Iab: 399 06 20 18.793 -30 03 48.12 30122 3.02 -0.160 2.830 3.000 -99.999 -99.999 -99.999 B2.5V 400 06 22 41.985 -17 57 21.30 30324 1.98 -0.240 1.750 -99.999 -99.999 -99.999 -99.999 B1II/III 401 --- removed due to strong emission lines 402 06 37 45.671 -43 11 45.36 31685 3.17 -0.103 3.077 3.171 3.514 3.490 3.557 B8III 403 --- removed due to strong emission lines 404 06 58 37.548 -28 58 19.50 33579 1.50 -0.211 1.386 1.513 -99.999 -99.999 -99.999 B2Iab: 405 07 38 49.870 -26 48 13.81 37229 3.80 -0.159 3.610 3.800 -99.999 -99.999 -99.999 B5IV 406 07 56 46.714 -52 58 56.50 38827 3.46 -0.177 3.287 3.444 3.951 3.919 3.956 B3IVp 407 08 03 35.047 -40 00 11.33 39429 2.21 -0.269 2.013 2.210 2.790 2.955 2.968 O5Ia... 408 08 09 31.950 -47 20 11.72 39953 1.75 -0.145 1.667 1.808 2.150 2.250 2.100 WCv+... 409 08 40 17.585 -52 55 18.79 42536 3.60 -0.168 3.440 3.630 4.071 4.019 4.142 B3IV 410 08 43 35.538 -33 11 10.99 42828 3.68 -0.180 3.507 3.675 4.185 4.227 4.247 B1.5III 411 08 55 02.828 -60 38 40.59 43783 3.84 -0.104 3.740 3.800 4.193 4.202 4.098 B8.5II 412 09 10 58.085 -58 58 00.82 45080 3.43 -0.190 3.250 3.400 3.701 3.771 3.947 B2IV-V 413 09 11 16.720 -62 19 01.12 45101 3.96 -0.180 3.784 3.947 4.650 4.565 4.441 B3III 414 09 22 06.818 -55 00 38.40 45941 2.47 -0.141 2.326 2.464 2.862 2.929 3.029 B2IV-V 415 10 32 48.672 +09 18 23.71 51624 3.84 -0.148 3.694 3.842 4.266 4.264 4.275 B1Iab 416 10 42 57.401 -64 23 40.02 52419 2.74 -0.220 2.540 2.780 -99.999 -99.999 -99.999 B0Vp 417 11 21 00.407 -54 29 27.67 55425 3.90 -0.157 3.740 3.900 4.139 4.170 4.307 B5Vn 418 --- removed due to strong emission lines 419 12 11 39.111 -52 22 06.46 59449 3.97 -0.156 3.809 3.951 4.203 4.302 4.420 B3V 420 12 15 08.716 -58 44 56.14 59747 2.79 -0.193 2.587 2.775 3.328 3.440 3.532 B2IV 421 12 15 48.370 -17 32 30.95 59803 2.58 -0.107 2.480 2.590 -99.999 -99.999 -99.999 B8III 422 12 26 35.896 -63 05 56.73 60718 0.77 -0.243 0.560 0.810 -99.999 -99.999 -99.999 B1 423 12 28 02.382 -50 13 50.29 60823 3.91 -0.192 3.719 3.897 4.401 4.435 4.478 B2V 424 12 32 28.015 -72 07 58.76 61199 3.84 -0.157 3.694 3.830 4.325 4.293 4.254 B5V 425 12 37 11.018 -69 08 08.03 61585 2.69 -0.176 2.505 2.677 -99.999 -99.999 -99.999 B2IV-V 426 12 46 16.806 -68 06 29.23 62322 3.04 -0.178 2.910 3.070 -99.999 -99.999 -99.999 B2.5V 427 12 47 43.263 -59 41 19.55 62434 1.25 -0.238 1.145 1.297 1.782 1.914 1.978 B0.5IV 428 13 25 11.579 -11 09 40.76 65474 0.98 -0.235 0.910 1.040 1.461 1.615 1.694 B1III-IV+... 429 13 39 53.258 -53 27 59.02 66657 2.29 -0.171 2.098 2.265 -99.999 -99.999 -99.999 B1III 430 13 49 30.277 -41 41 15.75 67464 3.41 -0.225 3.190 3.390 4.014 4.139 4.240 B2IV 431 --- removed due to strong emission lines 432 13 55 32.386 -47 17 18.15 68002 2.55 -0.176 2.343 2.515 3.022 3.083 3.220 B2.5IV 433 13 58 16.266 -42 06 02.71 68245 3.83 -0.224 3.612 3.806 4.628 4.461 4.491 B2IV 434 13 58 40.748 -44 48 12.90 68282 3.87 -0.208 3.653 3.842 4.721 4.597 4.469 B2IV-V 435 14 03 49.404 -60 22 22.94 68702 0.61 -0.231 0.380 0.600 1.167 1.209 1.278 B1III 436 14 19 24.222 -46 03 29.14 69996 3.55 -0.184 3.375 3.536 3.970 3.893 4.102 B2.5IV 437 --- removed due to strong emission lines 438 14 41 55.756 -47 23 17.52 71860 2.30 -0.154 2.125 2.276 2.634 2.718 2.668 B1.5III 439 14 58 31.927 -43 08 02.26 73273 2.68 -0.184 2.486 2.665 3.146 3.159 3.251 B2III 440 14 59 09.685 -42 06 15.10 73334 3.13 -0.208 2.930 3.130 3.416 3.356 3.378 B2IV 441 15 05 07.086 -47 03 04.48 73807 3.91 -0.144 3.750 3.890 -99.999 -99.999 -99.999 B5 442 15 21 22.322 -40 38 51.06 75141 3.22 -0.227 3.008 3.203 3.781 3.801 3.960 B1.5IV 443 15 22 40.871 -44 41 22.64 75264 3.37 -0.191 3.198 3.367 -99.999 -99.999 -99.999 B2IV-V 444 15 35 08.448 -41 10 00.33 76297 2.80 -0.216 2.586 2.765 -99.999 -99.999 -99.999 B2IV 445 15 38 39.370 -29 46 39.91 76600 3.66 -0.177 3.490 3.644 3.990 4.046 4.120 B2.5V 446 15 56 53.076 -29 12 50.66 78104 3.87 -0.199 3.685 3.864 4.343 4.518 4.457 B2IV-V 447 15 58 51.113 -26 06 50.78 78265 2.89 -0.180 2.700 2.890 3.465 3.500 3.686 B1V+... 448 16 00 07.328 -38 23 48.14 78384 3.42 -0.206 3.211 3.412 -99.999 -99.999 -99.999 B2.5IV 449 --- removed due to strong emission lines 450 16 35 52.954 -28 12 57.66 81266 2.82 -0.206 2.613 2.814 3.444 3.478 3.705 B0.2V 451 16 51 52.232 -38 02 50.57 82514 3.00 -0.200 2.820 2.980 3.458 3.482 3.696 B1.5Vp+... 452 16 52 20.144 -38 01 03.13 82545 3.56 -0.210 3.357 3.544 -99.999 -99.999 -99.999 B2IV 453 17 22 00.578 -24 59 58.36 84970 3.27 -0.186 3.067 3.248 3.631 3.656 3.831 B2IV 454 17 25 23.659 -56 22 39.82 85267 3.31 -0.150 3.176 3.312 -99.999 -99.999 -99.999 B1Ib 455 17 30 45.836 -37 17 44.92 85696 2.70 -0.179 2.470 2.700 3.053 3.108 3.183 B2IV 456 17 31 05.913 -60 41 01.85 85727 3.60 -0.104 3.520 3.600 3.698 3.651 3.710 B8Vn 457 --- removed due to strong emission lines 458 17 33 36.520 -37 06 13.76 85927 1.62 -0.231 1.480 1.620 2.013 2.068 2.114 B2IV+... 459 17 42 29.275 -39 01 47.94 86670 2.39 -0.171 2.208 2.375 2.892 3.015 3.094 B1.5III 460 18 06 37.871 -50 05 29.32 88714 3.65 -0.101 3.565 3.663 4.021 3.932 4.041 B2Ib 461 18 26 58.416 -45 58 06.45 90422 3.49 -0.179 3.323 3.477 3.914 3.950 4.108 B3IV 462 18 45 39.386 -26 59 26.80 92041 3.17 -0.107 3.074 3.161 3.273 3.241 3.280 B8III 463 18 55 15.926 -26 17 48.20 92855 2.05 -0.134 1.925 2.058 2.334 2.409 2.437 B2V 464 19 23 53.176 -40 36 57.38 95347 3.96 -0.105 3.867 3.950 -99.999 -99.999 -99.999 B8V 465 20 25 38.858 -56 44 06.32 100751 1.94 -0.118 1.795 1.910 2.304 2.458 2.479 B2IV ---------------------------------------------------------------------------------------------------