#Relative Filter Curve created with the VISIR imaging detector and the VISIR calibration unit. #Author = Maximilian Haeberle Contact: max.haeberle18@gmail.com # #Filter = NEII_1 #Central_Wavelength = 12.2171 #FWHM =0.18 # #Minimum_Wavelength = 11.7168 #Maximum_Wavelength = 12.7128 #Wavelength Step = 0.0120001 # #Exposure information #DIT = 0.0364452 #NDIT = 50 #NABBA = 2 # #Data Analysis Information #Zeroth Order = 192 #Normalization factor=30498.3 #Aperture r0= 10.0 #Annulus rA1= 31.7 #Annulus rA2= 37.7 #Mean of first background file = 19273.0742188 # #encvalue wavelength transmission transmission_error 9956.0 11.7168 0.0103224 0.00818704 9966.0 11.7288 0.00330224 0.00818704 9976.0 11.7408 0.00760665 0.00818704 9986.0 11.7528 -0.0109581 0.00818704 9996.0 11.7648 -0.00455849 0.00818704 10006.0 11.7768 -0.00452672 0.00818704 10016.0 11.7888 0.00352239 0.00818704 10026.0 11.8008 0.00501662 0.00818704 10036.0 11.8128 0.0127229 0.00818704 10046.0 11.8248 -0.00302315 0.00818704 10056.0 11.8368 0.00165437 0.00818704 10066.0 11.8488 0.0126833 0.00818704 10076.0 11.8608 -0.0025234 0.00818704 10086.0 11.8728 0.000904929 0.00818704 10096.0 11.8848 -0.0063744 0.00818704 10106.0 11.8968 -0.00122703 0.00818704 10116.0 11.9088 -0.00593038 0.00818704 10126.0 11.9208 0.0224795 0.00818704 10136.0 11.9328 -0.009197 0.00818704 10146.0 11.9448 0.00763118 0.00818704 10156.0 11.9568 -0.00483624 0.00818704 10166.0 11.9688 0.0160544 0.00818704 10176.0 11.9808 0.00742274 0.00818704 10186.0 11.9928 -0.00451359 0.00818704 10196.0 12.0048 0.0160926 0.00818704 10206.0 12.0168 0.0138951 0.00818704 10216.0 12.0288 0.0220348 0.00818704 10226.0 12.0408 0.0170862 0.00818704 10236.0 12.0528 0.0732748 0.00818704 10246.0 12.0648 0.0798552 0.00818704 10256.0 12.0768 0.106535 0.00818704 10266.0 12.0888 0.170416 0.00818704 10276.0 12.1008 0.245759 0.00818704 10286.0 12.1128 0.352091 0.00818704 10296.0 12.1248 0.444528 0.00818704 10306.0 12.1368 0.610074 0.00818704 10316.0 12.1488 0.739811 0.00818704 10326.0 12.1608 0.830589 0.00818704 10336.0 12.1728 0.885319 0.00818704 10346.0 12.1848 0.962421 0.00818704 10356.0 12.1968 1.0 0.00818704 10366.0 12.2088 0.957334 0.00818704 10376.0 12.2208 0.921748 0.00818704 10386.0 12.2328 0.926693 0.00818704 10396.0 12.2448 0.939011 0.00818704 10406.0 12.2568 0.854827 0.00818704 10416.0 12.2688 0.834997 0.00818704 10426.0 12.2808 0.767968 0.00818704 10436.0 12.2928 0.712023 0.00818704 10446.0 12.3048 0.560163 0.00818704 10456.0 12.3168 0.43624 0.00818704 10466.0 12.3288 0.311278 0.00818704 10476.0 12.3408 0.198103 0.00818704 10486.0 12.3528 0.135906 0.00818704 10496.0 12.3648 0.0871624 0.00818704 10506.0 12.3768 0.0472995 0.00818704 10516.0 12.3888 0.0416487 0.00818704 10526.0 12.4008 0.0178187 0.00818704 10536.0 12.4128 0.0170358 0.00818704 10546.0 12.4248 0.0183576 0.00818704 10556.0 12.4368 0.00193814 0.00818704 10566.0 12.4488 0.000424862 0.00818704 10576.0 12.4608 0.0166338 0.00818704 10586.0 12.4728 -0.00848764 0.00818704 10596.0 12.4848 0.0064015 0.00818704 10606.0 12.4968 0.00531863 0.00818704 10616.0 12.5088 0.0108883 0.00818704 10626.0 12.5208 0.00482031 0.00818704 10636.0 12.5328 0.0124632 0.00818704 10646.0 12.5448 0.00494656 0.00818704 10656.0 12.5568 -0.00853737 0.00818704 10666.0 12.5688 -0.0056074 0.00818704 10676.0 12.5808 0.00307809 0.00818704 10686.0 12.5928 -0.00628181 0.00818704 10696.0 12.6048 0.0130601 0.00818704 10706.0 12.6168 0.000782016 0.00818704 10716.0 12.6288 0.009144 0.00818704 10726.0 12.6408 -0.00637793 0.00818704 10736.0 12.6528 -0.00829823 0.00818704 10746.0 12.6648 0.00449203 0.00818704 10756.0 12.6768 0.00587066 0.00818704 10766.0 12.6888 -0.010753 0.00818704 10776.0 12.7008 0.0014742 0.00818704 10786.0 12.7128 -0.000334534 0.00818704