U-FORS Wavelength (nm) %T 1500 12.33789444 1498 12.1599493 1496 11.98963642 1494 11.80073929 1492 11.60949039 1490 11.42829037 1488 11.23938084 1486 11.03312874 1484 10.82973194 1482 10.62914085 1480 10.41653252 1478 10.20446682 1476 9.987909317 1474 9.775361061 1472 9.560200691 1470 9.340074539 1468 9.116898537 1466 8.898275375 1464 8.679881096 1462 8.46667099 1460 8.244059563 1458 8.043054581 1456 7.854093552 1454 7.63201952 1452 7.454992294 1450 7.268161297 1448 7.094183445 1446 6.897751808 1444 6.730726242 1442 6.576564789 1440 6.411322117 1438 6.268205643 1436 6.117312908 1434 5.979230881 1432 5.855191231 1430 5.719966888 1428 5.607980728 1426 5.501224995 1424 5.375509739 1422 5.279930115 1420 5.186121464 1418 5.087594509 1416 4.997922421 1414 4.907126904 1412 4.821022034 1410 4.745821476 1408 4.656972408 1406 4.578771591 1404 4.501038551 1402 4.418561459 1400 4.340132713 1398 4.250229359 1396 4.189488411 1394 4.102493763 1392 4.024578094 1390 3.948749542 1388 3.877301455 1386 3.81519413 1384 3.751295805 1382 3.705945253 1380 3.665647984 1378 3.640766859 1376 3.635881901 1374 3.623488188 1372 3.603438377 1370 3.563885689 1368 3.505567789 1366 3.443636417 1364 3.366208076 1362 3.303048849 1360 3.208041191 1358 3.127584696 1356 3.049806595 1354 2.958305359 1352 2.864237547 1350 2.778428793 1348 2.680430651 1346 2.587462664 1344 2.490128517 1342 2.399976492 1340 2.30675745 1338 2.206884384 1336 2.11529541 1334 2.030727386 1332 1.930802464 1330 1.855502486 1328 1.76142323 1326 1.678147316 1324 1.606470346 1322 1.531392932 1320 1.460008502 1318 1.389360309 1316 1.32291162 1314 1.266132474 1312 1.206737876 1310 1.152227402 1308 1.102433205 1306 1.054085612 1304 1.011404634 1302 0.971651793 1300 0.92781055 1298 0.890026629 1296 0.858624399 1294 0.827570915 1292 0.79816097 1290 0.769343019 1288 0.743895054 1286 0.718806326 1284 0.703700662 1282 0.673263431 1280 0.655606687 1278 0.636811853 1276 0.621511698 1274 0.607802749 1272 0.590305805 1270 0.5754264 1268 0.562289178 1266 0.55057317 1264 0.535473406 1262 0.52386564 1260 0.512096584 1258 0.502355278 1256 0.49095732 1254 0.481584758 1252 0.46933046 1250 0.461921603 1248 0.447457224 1246 0.434213042 1244 0.421345294 1242 0.420572996 1240 0.400280058 1238 0.390690148 1236 0.384266257 1234 0.368658304 1232 0.352104068 1230 0.344326288 1228 0.333872199 1226 0.31414035 1224 0.310855776 1222 0.301341236 1220 0.289745092 1218 0.270764053 1216 0.267816961 1214 0.2436537 1212 0.241308153 1210 0.229476392 1208 0.220867127 1206 0.206481546 1204 0.200639829 1202 0.193424925 1200 0.18537344 1198 0.176773086 1196 0.165611476 1194 0.167495996 1192 0.15549098 1190 0.147467285 1188 0.141997248 1186 0.134471938 1184 0.127022848 1182 0.12593706 1180 0.11699903 1178 0.112121306 1176 0.107056476 1174 0.103260003 1172 0.101201445 1170 0.091573849 1168 0.093753837 1166 0.085675791 1164 0.087636635 1162 0.077174753 1160 0.075807221 1158 0.070311569 1156 0.066786647 1154 0.067365341 1152 0.075295717 1150 0.054340951 1148 0.051546626 1146 0.052098475 1144 0.051995654 1142 0.043993063 1140 0.053114649 1138 0.04728248 1136 0.04274787 1134 0.041278325 1132 0.0425147 1130 0.036932867 1128 0.036729202 1126 0.034500569 1124 0.033314493 1122 0.029794427 1120 0.030985165 1118 0.029692912 1116 0.029101837 1114 0.025272401 1112 0.029087309 1110 0.026225615 1108 0.020840967 1106 0.02182431 1104 0.029076869 1102 0.023713192 1100 0.023734434 1098 0.01756791 1096 0.019510185 1094 0.019482812 1092 0.019098785 1090 0.020830976 1088 0.016811553 1086 0.017560598 1084 0.018154399 1082 0.016998267 1080 0.016836938 1078 0.014406192 1076 0.01424305 1074 0.018826809 1072 0.025208224 1070 0.005910747 1068 0.01048564 1066 0.010664128 1064 0.011846395 1062 0.008723626 1060 0.007916059 1058 0.009125297 1056 0.010896206 1054 0.00914522 1052 0.008765244 1050 0.006349367 1048 0.008770943 1046 0.007073602 1044 0.009544192 1042 0.005874987 1040 0.006546305 1038 0.004070565 1036 0.005123969 1034 0.003496635 1032 0.006098174 1030 0.00111307 1028 0.003818265 1026 0.008622555 1024 0.002561825 1022 0.005148422 1020 0.001916906 1018 0.002558995 1016 0.002848446 1014 0.000755226 1012 0.00439699 1010 0.017032696 1008 -0.003674671 1006 0.002131494 1004 0.002312508 1002 0.000997293 1000 -0.001928025 998 0.006831394 996 0.003670129 994 0.004162227 992 0.002549234 990 0.002708173 988 0.002254918 986 0.000921136 984 0.002426758 982 0.002612937 980 0.003692719 978 -0.005019068 976 -0.000515475 974 -0.001299163 972 0.002824747 970 0.005229088 968 0.000819577 966 0.001538418 964 0.001741044 962 0.000417857 960 1.93E-05 958 0.001518886 956 0.002182312 954 0.00508774 952 -0.001128405 950 0.004211087 948 0.002753251 946 0.017604763 944 -0.00944021 942 -0.00228041 940 -0.001389138 938 0.003281889 936 -0.002996511 934 0.001419843 932 0.001913392 930 0.004659079 928 0.001727583 926 0.00035243 924 0.003562551 922 -0.001078449 920 0.005787489 918 0.000309405 916 0.00132396 914 0.000139678 912 0.001286928 910 -0.000657219 908 0.002413799 906 3.30E-05 904 -0.000470262 902 -0.004407438 900 0.006318992 898 0.005880506 896 0.000208305 894 -0.005788317 892 0.002621077 890 0.005538814 888 0.003419206 886 0.000212489 884 -0.000598722 882 0.012911939 880 -0.003737326 878 -0.00231283 876 -0.001591091 874 0.000764995 872 0.004076673 870 0.001661103 868 -0.005677627 866 0.00512666 864 0.003602857 862 0.003984311 860 0.001899935 858 -0.001094012 856 -0.000488192 854 0.001127392 852 -0.000241593 850 0.00336765 848 0.004292846 846 0.003068996 844 0.001472992 842 -0.000974474 840 0.002451334 838 -0.002074742 836 -0.001369115 834 0.002177909 832 0.002144652 830 0.000896132 828 0.000364509 826 -0.000760178 824 0.001379942 822 0.000165231 820 0.00111921 818 0.000111347 816 0.000681097 814 0.000788812 812 0.000209202 810 0.000822463 808 0.002095678 806 -0.000190031 804 8.57E-05 802 -0.000317014 800 0.000149951 798 0.001155788 796 -0.000715509 794 0.000692172 792 0.000419408 790 0.000555848 788 0.001024806 786 0.001223641 784 0.001623493 782 0.000687832 780 0.000554753 778 0.000822261 776 0.00022197 774 -4.82E-05 772 0.000824448 770 0.000353378 768 -0.000510862 766 -0.000381935 764 -4.54E-05 762 0.001949521 760 0.003811062 758 0.001483056 756 0.0003555 754 2.17E-05 752 0.000285225 750 0.00108185 748 0.000750336 746 1.80E-05 744 2.28E-05 742 8.87E-05 740 -4.01E-05 738 0.00067995 736 8.33E-05 734 0.000941698 732 -0.000310112 730 9.18E-05 728 0.000813218 726 0.000155682 724 -0.000117975 722 0.000284391 720 0.000870967 718 0.00067565 716 0.000679429 714 8.30E-05 712 0.000152355 710 -0.000565058 708 0.00028451 706 -0.000172547 704 0.000417584 702 8.31E-05 700 -0.000302599 698 0.000347319 696 0.000219478 694 8.79E-05 692 0.000543955 690 0.000803297 688 2.65E-05 686 0.000545377 684 -0.000748921 682 -0.000495219 680 0.00028289 678 0.00054615 676 0.000739915 674 0.000866203 672 -0.000356116 670 -0.000230464 668 0.000995507 666 3.59E-05 664 0.001189449 662 0.000156216 660 0.000416542 658 -3.12E-05 656 0.000676615 654 0.000739243 652 0.000930278 650 0.001057986 648 2.83E-05 646 0.001181667 644 0.000605549 642 0.000603862 640 -0.000231907 638 0.000152825 636 0.001871891 634 0.000720725 632 0.000904037 630 0.000390939 628 0.000706255 626 0.000325301 624 0.00101982 622 0.000317576 620 0.001271934 618 -0.000202743 616 0.001336874 614 0.000190966 612 0.000130524 610 0.000387897 608 1.36E-05 606 0.000584644 604 -4.56E-05 602 0.000780376 600 0.000528315 598 0.000463574 596 0.000845729 594 0.000529554 592 0.000522352 590 0.000644129 588 -0.000504418 586 0.000247125 584 0.00063064 582 -0.000496084 580 0.001404777 578 0.000555421 576 0.001211341 574 -0.000402084 572 0.000374091 570 0.001535245 568 0.000259744 566 -0.00025037 564 0.000134517 562 0.000833156 560 0.000898032 558 -0.000119154 556 0.000578826 554 0.000961967 552 -0.000184201 550 0.000578399 548 -0.000565696 546 9.48E-06 544 0.000274895 542 1.31E-05 540 0.000522188 538 -0.000173937 536 0.001089322 534 0.000326244 532 0.001213569 530 0.000645526 528 -0.000245863 526 6.88E-05 524 0.000202531 522 0.000389445 520 0.000137297 518 0.001085551 516 -0.000744582 514 -0.000233252 512 0.0002626 510 -0.001001161 508 0.001145894 506 0.000259922 504 -0.000561928 502 0.000703894 500 0.000136231 498 0.000515985 496 0.001145768 494 0.000200401 492 9.65E-06 490 0.000954655 488 0.000828468 486 0.001017733 484 0.000516925 482 0.000513205 480 7.48E-05 478 0.001268689 476 0.000193839 474 0.000133385 472 0.000258203 470 -0.000177309 468 -0.000247841 466 0.000383656 464 0.000322434 462 0.000195221 460 -0.000433708 458 6.89E-05 456 0.00025961 454 0.000449516 452 7.13E-05 450 0.000130779 448 0.000635537 446 -0.000682551 444 0.000634243 442 0.00013119 440 0.000444079 438 0.000195272 436 0.000695703 434 -0.000187003 432 0.000632992 430 -0.000510607 428 -0.000432834 426 0.000181834 424 0.000189036 422 0.000309806 420 -0.000328462 418 0.00094324 416 0.00043794 414 0.000241941 412 0.000496095 410 -0.000205743 408 0.000173451 406 0.001634166 404 0.001252319 402 0.002716049 400 0.005838174 398 0.017826982 396 0.058740795 394 0.257964373 392 1.441918731 390 8.374047279 388 29.16237068 386 58.66581345 384 79.7430191 382 87.81122589 380 88.67375946 378 87.46155548 376 85.75481415 374 84.20184326 372 83.44275665 370 83.59967804 368 83.8660965 366 83.78349304 364 83.26164246 362 82.84771729 360 82.47867584 358 81.94657898 356 81.04933167 354 79.99835968 352 78.71244812 350 76.83620453 348 74.29480743 346 71.02267456 344 66.72249603 342 62.27180481 340 58.08354568 338 52.8489418 336 45.77093887 334 38.87973022 332 32.2677536 330 24.88032913 328 18.26254654 326 13.70058537 324 9.786740303 322 6.048472881 320 3.494122267 318 2.0429914 316 0.937304258 314 0.253898889 312 0.093500867 310 0.023891581 308 -0.006801509 306 -0.011415768 304 -0.016902145 302 -0.008922894 300 -0.004939408