g-fors Wavelength (nm) %T 1500 10.93847084 1498 10.71259785 1496 10.4994936 1494 10.29219818 1492 10.08850288 1490 9.904396057 1488 9.713535309 1486 9.529173851 1484 9.3519907 1482 9.177448273 1480 9.009647369 1478 8.847316742 1476 8.694754601 1474 8.542428017 1472 8.399046898 1470 8.260047913 1468 8.120223045 1466 7.981142521 1464 7.848750114 1462 7.727514744 1460 7.591765404 1458 7.474006653 1456 7.36247921 1454 7.245919704 1452 7.133125305 1450 7.03118515 1448 6.926214695 1446 6.822002888 1444 6.717453957 1442 6.618313313 1440 6.515458107 1438 6.418494225 1436 6.318237782 1434 6.224143505 1432 6.123514652 1430 6.032445431 1428 5.934292793 1426 5.837300301 1424 5.743434429 1422 5.647668362 1420 5.554094315 1418 5.455384731 1416 5.351597786 1414 5.25675869 1412 5.144278526 1410 5.050474167 1408 4.940083981 1406 4.841834545 1404 4.744561195 1402 4.648417473 1400 4.547602177 1398 4.448232174 1396 4.366878986 1394 4.258677483 1392 4.165500641 1390 4.063670635 1388 3.981516838 1386 3.883271217 1384 3.780413389 1382 3.67586422 1380 3.564060211 1378 3.462767601 1376 3.354629993 1374 3.254723549 1372 3.159658194 1370 3.04925561 1368 2.956703186 1366 2.85503602 1364 2.762219906 1362 2.678799868 1360 2.57277894 1358 2.48643136 1356 2.408533812 1354 2.314380169 1352 2.241444826 1350 2.161550522 1348 2.085020542 1346 2.018061876 1344 1.947361231 1342 1.877041936 1340 1.818194747 1338 1.757009149 1336 1.698390245 1334 1.642598152 1332 1.587612867 1330 1.540761352 1328 1.484717011 1326 1.435507417 1324 1.392801046 1322 1.354797482 1320 1.311117053 1318 1.266689301 1316 1.230312586 1314 1.194417357 1312 1.171652436 1310 1.12716198 1308 1.097201824 1306 1.070985794 1304 1.040980101 1302 1.011401534 1300 0.984718204 1298 0.964678049 1296 0.936763823 1294 0.91978538 1292 0.887656331 1290 0.865462959 1288 0.844589829 1286 0.824688375 1284 0.801594853 1282 0.782013297 1280 0.757115006 1278 0.742879689 1276 0.716198564 1274 0.697851062 1272 0.67901814 1270 0.656427085 1268 0.640537143 1266 0.625400245 1264 0.600768328 1262 0.575936198 1260 0.561767519 1258 0.542269945 1256 0.521483064 1254 0.503673136 1252 0.483210564 1250 0.459597647 1248 0.443252325 1246 0.426262677 1244 0.40499574 1242 0.390309453 1240 0.372883588 1238 0.352117598 1236 0.341239393 1234 0.323033065 1232 0.31539464 1230 0.291953921 1228 0.276200324 1226 0.264519721 1224 0.255337417 1222 0.240627632 1220 0.231806561 1218 0.226920441 1216 0.205364212 1214 0.200989917 1212 0.191886947 1210 0.182363913 1208 0.173897371 1206 0.169772208 1204 0.1601547 1202 0.153691307 1200 0.142756388 1198 0.147888452 1196 0.139541179 1194 0.126555905 1192 0.126982778 1190 0.12397667 1188 0.115157269 1186 0.11086832 1184 0.108842403 1182 0.106444374 1180 0.100859106 1178 0.100184567 1176 0.095394827 1174 0.086931974 1172 0.088701338 1170 0.085419372 1168 0.087346628 1166 0.080667563 1164 0.081372701 1162 0.074170701 1160 0.074671529 1158 0.069167241 1156 0.070310064 1154 0.066789575 1152 0.059892144 1150 0.063728735 1148 0.060018275 1146 0.059684727 1144 0.056692258 1142 0.05035986 1140 0.047005363 1138 0.046771385 1136 0.043255135 1134 0.04191361 1132 0.04121783 1130 0.03966365 1128 0.049024589 1126 0.025693409 1124 0.029677112 1122 0.027008023 1120 0.030599551 1118 0.029886011 1116 0.025840089 1114 0.02429988 1112 0.026023626 1110 0.023541106 1108 0.021418016 1106 0.021419548 1104 0.018166814 1102 0.015293121 1100 0.014494675 1098 0.017578611 1096 0.016069759 1094 0.015408533 1092 0.017989596 1090 0.018321304 1088 0.011260031 1086 0.018718949 1084 0.012017502 1082 0.010690088 1080 0.008423121 1078 0.007178338 1076 0.009272493 1074 0.010007514 1072 0.01263866 1070 0.010494061 1068 0.011825636 1066 0.010298261 1064 0.008421888 1062 0.010474968 1060 0.005953401 1058 0.010245743 1056 0.010916452 1054 0.009165732 1052 0.009911238 1050 0.008020709 1048 0.006569611 1046 0.009689665 1044 0.006900569 1042 0.006491802 1040 0.005159532 1038 0.005375986 1036 0.004003321 1034 0.003439272 1032 0.007455327 1030 0.000718497 1028 0.005791805 1026 -0.002497677 1024 0.005570603 1022 0.00439604 1020 0.007698428 1018 0.00388051 1016 0.004306528 1014 0.005367022 1012 0.003837909 1010 0.005847474 1008 -0.000595943 1006 -0.001177153 1004 0.004240203 1002 0.00255357 1000 0.004509855 998 0.000153399 996 0.001919145 994 0.000456343 992 0.001948939 990 -0.007506827 988 0.004188474 986 0.004713589 984 0.00236498 982 0.001232708 980 0.000172452 978 -0.000193144 976 0.007344947 974 0.003019719 972 -0.000711915 970 -0.000856026 968 0.003388391 966 0.00232894 964 0.001340837 962 0.001215391 960 0.005179033 958 0.002896972 956 -0.002014089 954 0.001904062 952 -0.000725479 950 0.003635113 948 -0.00327734 946 0.007261433 944 3.99E-06 942 -0.003263755 940 0.002831965 938 0.004287035 936 0.000264306 934 0.003641696 932 -0.00471022 930 0.001241652 928 -0.00108134 926 0.006412375 924 0.008005268 922 -0.001685317 920 0.000515637 918 0.00174148 916 -0.003341231 914 0.003562346 912 0.004159978 910 0.003419182 908 0.001192341 906 0.008597074 904 -0.00335881 902 -0.000136186 900 0.00736869 898 0.001209982 896 -0.003853706 894 0.003036598 892 -0.004759274 890 0.00345039 888 0.00321695 886 -0.001834274 884 -0.001211875 882 0.001412597 880 -0.00051433 878 0.00740712 876 -0.001630881 874 0.00364576 872 0.002883609 870 -0.00079556 868 -0.000753027 866 -0.003095191 864 0.001143551 862 -0.001142817 860 -0.001551262 858 -0.001308856 856 0.00502423 854 -0.000375137 852 -0.001402791 850 0.003175015 848 -0.005749454 846 0.001419591 844 0.002882585 842 0.005211907 840 -0.004945754 838 -0.004163934 836 0.00432647 834 0.003392105 832 0.003202423 830 0.001386251 828 0.001617112 826 0.000672968 824 -0.000220769 822 0.000327329 820 0.001509542 818 -4.32E-05 816 0.001537042 814 -0.000321509 812 0.001286302 810 0.000954679 808 0.000820433 806 0.001760307 804 0.001424939 802 0.001425727 800 0.002165959 798 0.001159012 796 0.002024716 794 0.000826204 792 0.001024676 790 0.000755842 788 0.000623018 786 0.001623058 784 0.000217488 782 0.001689684 780 0.001822614 778 0.001688872 776 0.002952193 774 0.00375074 772 0.004286503 770 0.004695663 768 0.004547264 766 0.004480076 764 0.002016367 762 0.001949348 760 0.000885762 758 0.000356869 756 0.001084648 754 -3.76E-05 752 -4.73E-05 750 0.001149182 748 0.001017612 746 0.000287815 744 0.000289029 742 0.000817013 740 -0.000629936 738 8.09E-05 736 0.000745807 734 0.000876727 732 -0.000633359 730 -0.000437803 728 -0.000365287 726 0.000417152 724 0.000613845 722 0.000875515 720 0.000808184 718 0.000544837 716 -0.000173789 714 -0.00017451 712 -0.000305921 710 0.000612281 708 9.24E-05 706 -0.000640332 704 -0.000629674 702 0.000216439 700 0.000739791 698 0.001128295 696 8.69E-05 694 -0.00017008 692 -3.34E-05 690 0.000218075 688 0.00067421 686 2.47E-05 684 0.000935177 682 0.000670736 680 -4.50E-05 678 9.14E-05 676 0.000155589 674 -0.00016598 672 0.000157836 670 -0.000676683 668 -0.000938017 666 0.000355798 664 2.82E-05 662 0.000737046 660 0.001121718 658 0.000805469 656 -0.000285236 654 0.000674088 652 -0.000483302 650 0.000865508 648 0.000223677 646 -0.000358294 644 0.000355767 642 0.000733037 640 0.000342049 638 8.97E-05 636 0.000851566 634 0.00020917 632 -0.000245534 630 0.000646197 628 0.000196781 626 0.000897153 624 -0.000459024 622 -0.000888192 620 0.000248135 618 5.38E-05 616 0.000316537 614 0.00025354 612 -0.000444031 610 0.000193081 608 0.000832874 606 8.30E-05 604 -0.000487814 602 0.000902408 600 0.000717973 598 0.000784225 596 0.000342864 594 1.80E-05 592 0.000586254 590 0.000198894 588 -0.000963355 586 0.000242882 584 0.00017407 582 0.000684155 580 0.001730521 578 0.001600543 576 0.001926012 574 0.00302202 572 0.005346566 570 0.007701237 568 0.012004413 566 0.021019651 564 0.035839468 562 0.068151593 560 0.130693004 558 0.275625646 556 0.619135022 554 1.583328247 552 4.545732498 550 14.46202374 548 42.19165039 546 76.56602478 544 86.9675827 542 88.09954834 540 90.13215637 538 91.30470276 536 90.3021698 534 88.51241302 532 87.67674255 530 88.30674744 528 89.91894531 526 91.51475525 524 92.21309662 522 92.00140381 520 91.32565308 518 90.90245819 516 91.07905579 514 91.71456146 512 92.52872467 510 93.28762054 508 93.65995789 506 93.5480957 504 93.01309204 502 92.14069366 500 91.2035675 498 90.42120361 496 90.09612274 494 90.31174469 492 91.08937073 490 92.15106964 488 93.02386475 486 93.13441467 484 92.3817749 482 90.94200134 480 89.41883087 478 88.3686142 476 88.17822266 474 88.73472595 472 89.72982788 470 90.72737122 468 91.26695251 466 91.35360718 464 91.24549866 462 91.17463684 460 91.14614105 458 91.04626465 456 90.34109497 454 89.26016998 452 88.05725861 450 87.26643372 448 87.20181274 446 87.73529816 444 88.5473938 442 88.95504761 440 88.77919006 438 87.98786163 436 87.13056183 434 86.64590454 432 86.42819214 430 86.29688263 428 86.03277588 426 85.64450073 424 85.36858368 422 85.09420013 420 84.3809967 418 83.17182159 416 81.59295654 414 80.26334381 412 79.69132996 410 79.73179626 408 79.53266907 406 78.42373657 404 76.48627472 402 74.59301758 400 73.44567108 398 72.60163116 396 71.16851044 394 68.25828552 392 64.0794754 390 58.72000504 388 51.20400238 386 39.98603058 384 26.09954262 382 13.11197281 380 4.782892704 378 1.16660285 376 0.182108089 374 0.022303814 372 0.007072536 370 0.003902191 368 0.005112696 366 0.004380886 364 0.004287413 362 0.005199389 360 0.004320747 358 0.004194201 356 0.005063212 354 0.004965106 352 0.004969162 350 0.004603572 348 0.001890568 346 0.002206145 344 0.00242075 342 0.000737698 340 0.004165351 338 0.006221864 336 0.003346226 334 0.004231049 332 0.003434628 330 0.004011794 328 0.002560993 326 0.005631482 324 0.001628202 322 -0.000955493 320 0.003171029 318 0.00527852 316 -0.000512731 314 8.74E-05 312 -0.000460523 310 -0.00473773 308 -0.005828338 306 -0.00872406 304 -0.007956868 302 0.006264204 300 -0.004220609