mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
ISAAC:
startrace.coeff
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
ISAAC trending system: FULL report
HELP USERS-GUIDE MORE
Last update: 2013-12-16T10:30:42 (UT)
  | now: 2026-04-17T12:46:16 (UT) muc03 QC pipeline: isaac-6.1.3 (installed 2013-04-15)
same group: SW_LR SW_MR LW_LR LW_MR   IMAGE
General news: NOTE: The Health Check and calChecker services have been moved to qcFlow. These pages are only maintained for comparison and will be removed in 2026.
ISAAC news: 2013-12-16: due to ISAAC decommissioning, refreshing of the health checks disabled
Report news:
DATE*: [?] 2013-12-09
report | NLT
2013-12-10
report | NLT
2013-12-11
report | NLT
2013-12-12
report | NLT
2013-12-13
no data | NLT
2013-12-14
no data | NLT
2013-12-15
no data | NLT
P...
Product quality:
products products products products no products no products no products
  no OPSLOG data  

scores&comments | history: all data plotted here | plot tutorial ... | contact               [?]
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB no none   ADU none  24 qc_corr_IL1 all (full time range) image to spectrum conversion for SW
1 oQC1DB no none   ADU none  15 qc_corr_IL1 all (full time range) image to spectrum conversion for LW
2 QC1DB no none   ADU none  24 qc_corr_IL2 all (full time range) image to spectrum conversion for SW
2 oQC1DB no none   ADU none  15 qc_corr_IL2 all (full time range) image to spectrum conversion for LW
3 QC1DB no none   ADU none  24 qc_corr_IL3 all (full time range) image to spectrum conversion for SW
3 oQC1DB no none   ADU none  15 qc_corr_IL3 all (full time range) image to spectrum conversion for LW
4 QC1DB no none   ADU none  24 qc_corr_IM1 all (full time range) image to spectrum conversion for SW
4 oQC1DB no none   ADU none  15 qc_corr_IM1 all (full time range) image to spectrum conversion for LW
5 QC1DB no none   ADU none  24 qc_corr_IM2 all (full time range) image to spectrum conversion for SW
5 oQC1DB no none   ADU none  15 qc_corr_IM2 all (full time range) image to spectrum conversion for LW
6 QC1DB no none   ADU none  24 qc_corr_IM3 all (full time range) image to spectrum conversion for SW
6 oQC1DB no none   ADU none  15 qc_corr_IM3 all (full time range) image to spectrum conversion for LW
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: OPSLOG data are included
Plot 1
scores: not implemented
data source:isaac_strace
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_corr_IL1
average:none
thresholds:none
N_data plotted:24
[click on plot for closeup]
Plot 2
scores: not implemented
data source:isaac_strace
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_corr_IL2
average:none
thresholds:none
N_data plotted:24
[click on plot for closeup]
Plot 3
scores: not implemented
data source:isaac_strace
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_corr_IL3
average:none
thresholds:none
N_data plotted:24
[click on plot for closeup]
Plot 4
scores: not implemented
data source:isaac_strace
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_corr_IM1
average:none
thresholds:none
N_data plotted:24
[click on plot for closeup]
Plot 5
scores: not implemented
data source:isaac_strace
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_corr_IM2
average:none
thresholds:none
N_data plotted:24
[click on plot for closeup]
Plot 6
scores: not implemented
data source:isaac_strace
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_corr_IM3
average:none
thresholds:none
N_data plotted:24
[click on plot for closeup]
This plot

This is the trending plot for the ISAAC startrace calibrations

The optical position transformation in y-direction between the star in the slit and the spectrum is described by a polynomial:

Y(image) = I1 + I2 * Y(spectrum) + I3 * Y^2(spectrum)

Startrace calibrations are acquired once per year. The image orientation is flipped between LR and MR grating, hence LR and MR coefficients differ. On 2006-01-01 (eclipse to cpl migration of the pipeline) the definition of the polynom has changed for the LR-grating only for reasons of homogenisation.

These plots describe:
Fig. 1. coefficient IL1, the offset in y for LR
Fig. 2. coefficient IL2, linear term in y for LR
Fig. 3. coefficient IL3, quadratic term in y for LR
Fig. 4. coefficient IM1, the offset in y for MR
Fig. 5. coefficient IM2, linear term in y for MR
Fig. 6. coefficient IM3, quadratic term in y for MR
Find more information about ISAAC QC parameters derived from arc lamp frames here.

 


General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up